Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 8:49pm On Apr 18, 2017
Environment Monitoring System
Environmental monitoring systems prevent hardware damage to server rooms, data centers and network closets with critical condition alerts and remote reboot capability.
Also known as: remote environment monitoring system, monitor server rooms, data center monitoring, computer room, network closet, temperature sensor, remote power reboot, web alert thermometers, server room monitoring.

Environmental threats in your server room can cause a lot more damage than hardware or software problems. Redundant hardware, backup tapes, UPS battery arrays, generators and other fault-tolerance measures can all be rendered useless if your server room overheats or floods. Don't ignore environmental threats – remotely manage them with our FCS range of Server Room Environment Monitoring System or Intelligent Power Distribution Control Unit via TCP/IP Ethernet protocol over CAT5 through an RJ45 connector.

Monitor Temperature The most common environmental threat in any server room or wiring closet is heat. Detect critical rises or drops in temperature, and receive notifications when heating problems occur.

Monitor Humidity Detect abnormal humidity conditions. You define the humidity levels that are appropriate for each sensor's environment.

Detect the Presence of Water Whether it's a tripped sprinkler system or a flash flood, a server room or wiring closet is just about the last place you want to see water. Receive notification as soon as water makes an appearance.

Monitor Physical Security Monitor "dry-contact" devices including motion sensors, door sensors, vibration sensors and smoke detectors.

Control Power Remotely reboot and control power (on/off) to servers and network devices.
And many more….

FCS Small Enterprise Server Room Monitoring System.
SNMP and Web monitoring/management of server room environments. Provides early warnings before critical events turn into disaster.
Also known as: Remote Server Environment Monitoring System, EMS, monitor network closet, data center thermometer, web alert thermometers temperature humidity IP sensor reading, computer rooms temperature alert, tcp/ip temp probe.

PRODUCTS DESCRIPTION
The FCS Small Enterprise Environment Monitoring System (EMS) monitors critical environmental conditions (such as temperature, humidity, and water leakage) that could destroy network components in your server room. When a sensor goes out of range of a configurable threshold, the system will notify you via email, SNMP traps, web-page alerts, a visual indicator (red LED), voice phone calls (via Automatic Voice Dialer System), and SMS messages (via USB 3G modem).

The system supports two external configurable sensors, five digital input sensors, and one output relay for control of external devices.
• Monitor and manage server room environmental conditions over IP.
• Sensors supported:
o 2 external configurable sensors
o 5 digital inputs sensitive to contact closure
o 8 Remote Temperature/Humidity Sensors over IP
 FCS: 1 integrated temperature sensor, 2 RJ45 ports for external temperature/humidity sensors, 2 digital inputs sensitive to contact closure, dual DC power (dual redundancy).
 FCS-MICRO-TRHP: 1 integrated temperature/humidity combination sensor, 2 RJ45 ports for external temperature/humidity sensors, 2 digital inputs sensitive to contact closure, built-in Power over Ethernet (POE), dual DC power (triple redundancy).
• One output relay for control of external devices.
o Relay activates upon alarm or via the user interface.
o Control output relays via SNMP SET commands to power on/off external devices.
• Supports IP network video cameras for live view of any facility.
o One integrated view – see different Web cameras side-by-side with physical and environmental parameters.
o Any programmed event can trigger a snapshot from an IP camera.
• Monitor (ping) up to 64 IP network devices.
o Alerts are sent if devices are not responding.
• Linux inside.
• Create multiple alerts for any installed sensor.
• Sensor conditions (events) can be configured to trigger alerts by themselves, and/or be used in combination with other events to trigger Smart Alerts.
o Configure up to 50 events.
 Setup SSH commands to be sent when events are triggered to soft shutdown or reboot machines.
o Up to 20 Smart Alerts can be configured to use different event combinations to send alert messages.
• Alerts are posted in message log, which is accessible through Web user interface.
• Automatically configures network settings received from a connected DHCP server.
o If a DHCP server is not found, the default static IP address will be used.
• Integrates with various Open Source monitoring packages – Nagios and MRTG.
o The unit can be polled via SNMP.
• Two USB ports for connecting USB modem or for downloading log data to USB flash drive, and one USB console port for serial terminal interface.
• Available with optional internal battery backup.
o Alerts are sent when there is a power outage and when power returns.
• Available with optional 24VDC power.
o Comes with a 24V DC-DC power converter built inside the unit.
• Up to five units can be used together to increase the number of sensors connected.
o Cascade up to four FCS-2D/5D/16D units as slaves to one FCS-2D/5D/16D master unit via Ethernet connection.
 Each master and slave unit needs its own unique IP address.
o Uses a single Web interface for all systems/sensors connected.
• Dual redundant power supplies for connection to two separate power sources.
o The second power supply is sold separately.
• Optional industrial small environment monitoring system for high temperature environments. This industrial system has the ability to operate and monitor in harsh environments at high temperatures up to 167°F (75°C).
• Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 units and all connected sensors.
• Flexible Zero-RU mounting.
o Mounting tabs included.
o Optional 1RU rackmount kit available; this FCS’s Server Room Monitoring Systems unit can be mounted with the front or rear facing out.
o Optional DIN mounting available.
• Security: HTTPS, SSHv2, SSLv3, IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
• Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.


CONTROL METHOD

Web Interface
• Configuration can be done over the Internet/LAN or 3G data connection via Web page.
o 3G data connection requires a USB 3G modem with a data plan.
 Email and SMS alerts can be sent through the modem instead of the Ethernet connection.
• Supports Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Netscape 9, Google Chrome, Safari 1.3 and higher for MAC, and Safari 3.0 and higher for PC.
• Configure sensor's thresholds, alarm methods, formats of alerts, and system data log.
o Customize SMS messages and email subject headers for sensor alerts.
• View/edit sensors' current values, thresholds and alert statuses.
o All sensors connected, including up to 8 Remote Temperature/Humidity Sensors over IP, to the FCS-2D can be viewed on one summary page.
o All sensors in alert can be quickly viewed on the alert summary page to enable timely responses.
o User configurable settings allow sensors to return to normal status when alert condition clears, without manually acknowledging/dismissing the alert.
• View/edit entries stored in the system logs.
o Event log records system events such as alerts, user login/logout, failed email messages, etc.
o Data log records samples of sensor readings. User specified sampling time period.
o Both the event log and the data log store up to 1,000 entries.
o The log can be downloaded as a tab-delimited plain text file.
• Configure IP information (address, subnet mask, default gateway, DNS, etc.), user administrative settings, and data logging settings.
• Upload custom x509 certificates.
• Up to 16 users can access the web page at one time.
• Configure up to 50 sensor conditions (events)
• Configure up to 20 Smart Alerts to use different event combinations to send alert messages.
• Up to five units can be used together to increase the number of sensors connected.
o Cascade up to four FCS-2D/5D/16D units as slaves to one FCS-2D/5D/16D master unit via Ethernet connection.
 Each master and slave unit needs its own unique IP address.
 IP sensors can only be connected to a master unit.
o Uses a single Web interface for all systems/sensors connected.

Front Panel Interface
• LEDs indicate the following:
o "Fault" (red) lights up if a sensor goes out of range of a configurable threshold.
o "Power" (green) lights up when the device is powered.
• Restore Defaults button – use to manually restore the FCS-2D back to factory settings.
• System Reset button – use to manually reboot/restart the firmware for the FCS-2D.

USB Serial Interface / Telnet / SSH
• Configure, control and monitor over the text-based menu system accessible via USB console port, Telnet, and SSH.
• Access is controlled via username/password.
o System stores encrypted login information.
• Two user levels: user and administrator.

Network Operation
• Automatically configures network settings received from a connected DHCP server.
o If a DHCP server is not found, the default static IP address will be used.
• SNMP support, allowing integration into network management platforms.
o Control output relays via SNMP SET commands to power on/off external devices.
 SET command can be sent from SNMP software, MIB browser (Windows), or command line (Linux).
• Updating the system firmware.

Mobile Summary Page
• View summary page on mobile devices – smartphones, tablets, etc.
• Summary page lists all connected sensors' current values and alert statuses.
Open Source Monitoring Integration
• SNMP Plugin for Nagios
• Using Multi Router Traffic Grapher.

Optional Management Software
• Optional intuitive graphical management software, provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 FCS-2D/5D/16D, FCS-SEMS-16(U)units and all connected sensors.
• Push configuration changes to multiple connected units in a group at once.
o E.g. new users, mail server, network settings, security settings, system settings, etc.

Optional Android App for Tablet/Phone
• Optional Android App provides an easy-to-use interface for monitoring and displaying sensor statuses from one FCS-2D/5D/16D

Sensors & Accessories - Sold Separately[size=12pt][/size]

Environmental Sensors
• Remote Temperature/Humidity Sensor over IP
• Temperature Sensors
• RTD Temperature Transmitters/Sensors
• Temperature/Humidity Sensors
• Industrial Temperature/Humidity Sensors
• Rope-Style Leak Detectors
• Spot Leak Detectors
• Under Carpet & Tape-Style Detectors
• Ultrasonic Level Transmitter
• Smoke Detectors
• Gas Detectors
• Air Flow/Velocity Detectors
• Outdoor Temperature Sensor
• Wind Speed Sensor
• Barometric Pressure Transmitter
• Pressure Sensors

Power Relays & Sensors
• Power Over Ethernet Adapters
• AC Voltage Detectors
• AC & DC Power Monitors
• Hall-Effect Sensors
• 3-Phase Power Monitors/Transducers
• Current Transformers

Security Sensors & Access Control
• Door Contact Sensors
• Vibration & Glass Break Sensors
• Motion Sensors
• Tamper Switch
• Emergency/Panic Button
• Access Control

Alert & Communication Accessories
• Automatic Voice Dialer Systems
• USB Modems
• IP Surveillance Cameras
• Siren Alarms
• Alarm Beacons

Sensor Accessories
• Digital Input/Output Expanders
• Fiber Converter/Extender
• Sensor Converters – 4-20mA, 5VDC
• Sensor Cables
• Surge Protectors
• Intrinsically Safe Barrier

Optional Replacement Back-up Battery

1 Like

Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 6:57pm On Apr 19, 2017
contact us for deployment in your server room or data center
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 10:32am On Jul 22, 2017
Deploy Building Management Systems"BMS" today to automate and control all electrical, electronic and mechanical equipment in your building, also monitor your remote site equipment, and know the condition of your equipment in far location
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 8:51am On Oct 01, 2017
TEMPERATURE/HUMIDITY & POWER SENSOR WITH SMS ALERT
Temperature/Humidity & Power Sensor Notifications & Alert
An essential part of any server room monitoring system is accurate temperature and humidity monitoring. High temperatures can lead to system failure, unwanted downtime and costly repairs. Our Intelligent G-Alert Temperature & Humidity sensors help to avoid these costly errors with easy to configure, cost effective systems that are ready to run, right out of the box.
Events that lead to IT equipment disaster and failure can be avoid by using G-Alert device to proactively alert the IT staff to maintain equipment correctly or to take corrective action. When events occur, this intelligent Monitoring system can be configured to send notifications alert at interval to an IT Staff

Temperature Sensor
Monitoring air temperature is essential in any area with IT equipment. It is particularly important to monitor air temperature in rooms, racks, and directly around the equipment. The common method of achieving this is by using intelligent temperature monitor sensors. If air temperature is not monitored, it can lead to equipment failure or a reduction in the equipment lifespan. This is caused by air temperatures above equipment specifications and frequent, drastic temperature changes.

An optimal environmental monitoring strategy includes intelligent temperature sensors like G-Alert. These should be placed on top, middle of server room close to the racks to measure the heat being generated by equipment, and at the air conditioning system’s intake and discharge vents, to measure efficiency. Probes should also be placed around critical devices, because the temperature inside a rack-mounted device could be as much as 20 degrees higher than the surrounding area. A probe near the room’s thermostat can help monitor what the thermostat is ‘seeing’ as it controls the air conditioner.

Humidity Sensor
High humidity may lead to corrosion on electronic components and low humidity levels may cause issues with static electricity. Humidity must be monitored at the room and rack level. The focus must be on the relative humidity at specific operating temperatures - not humidity level general. This is archived by using humidity sensor, if there is too little humidity, equipment failure can be caused by static electricity buildup. If there is too much humidity, condensation can cause equipment failure and create and unsafe working environment for personnel

Power Sensor
Monitoring Power supply in your server room is great advantage, you will be notify by SMS message as soon as electricity power goes out from your datacenter or server room, an IT STAFF can respond on time to safeguard unexpected total shut down of your equipment in sever room, this can also be use to monitor Inverter battery, UPS and the last Remote area Solar Power Plant.

Product Description
The G-Alert Environment Alarm is special for remotely monitoring onsite temperature, humidity, power status through wireless GSM Network. When the temperature, humidity, power voltage exceed high threshold or low threshold value, the system will send SMS alert to up to 10 preset mobile phones numbers immediately and automatically.
Just dial the system from Authorized User number, the G-Alert Environment Alarm will reject the call at the first “Ring" (no communication cost) and then return the current temperature, humidity, power status or voltage. Moreover, it can report onsite environment at intervals or daily.
The G-Alert Environment Alarm can be used for monitoring Server room, Office, Meeting Room, Laboratory, Library, Solar power, Class Room, Public Room, Waiting Room, Hospital, Warehouses, Stations, Remote sites or anywhere that requires monitoring of temperature, humidity and power.

Main Features
• Can be operated from anywhere, no distance limitation.
• No call charges for inquiry, the G-alert Environment Alarm rejects the call from authorized number then returns onsite temperature, humidity, and power voltage on the first 'ring'.
• Multiple applications (temperature, humidity, power status, solar panel, dc voltage)
• Up to 10 authorized phone numbers, 5 can be used to receive call or SMS, and 5 can be used to call and SMS during alarm occurrence.
• One Temperature & Humidity sensor input, measures temperatures from -40-80'C to 0.5°C accuracy.
• Relative Humidity from 0-99RH% , accuracy is 3%.
• External AC Power status monitoring, AC On/OFF will send SMS to authorized phone numbers.
• Inbuilt MCU monitoring the DC input Voltage value, measure range is 9-24VDC, no need for additional sensor to save cost.
• Timer Report—Can be setup to report parameters every x hours automatically by sending status/value to the authorized numbers.
• Support remote reading of historic data via SMS
• Rechargeable Backup Battery inside can last 8hours
• Secure - Using caller ID and password for identification, unknown callers are ignored;
• Programmable by SMS Commands or APPs with password protection
• Based on GSM Network
• Usable for many applications.

Standard Packing List
G-Alert Environment Alarm X 1;
Antenna X 1;
AC/DC adaptor(12V1 A) X1 ;
User Manual X 1.
Note: The package does not include any SIM card.

Technical specifications
Parameter item: Reference scope
DC Power supply: 9-24VDC, recommend 12VDC1A
Power consumption : 12V input Max. 50mA/Average30Ma
Frequency range SIM: 850/900/1800/1900Mhz
Card: Supporting 3V SIM Card
GSM Antenna: 50 Q SMA Antenna interface
Temperature range: -40-+80 °C
Humidity range: Relative humidity 0-90% (condensation free)
Temp&Humidity: Temperature&Humidity Sensor, -80°C (0.5°C accuracy) .Relative Humidity from 0-99RH%,
accuracy is 3%.

Sensor: W130mm*D74mm*H27mm
Backup Battery: 900mAH, lasts 8hours
Exterior dimension

Net Weight: 300 g

G-Alert: Environment monitoring over GSM/GPRS
• With the Android Application software, G-Alert can offer an instantly usable data collection solution.
Data outputs include logs+MS Excel analysis or a XML database.
• SMS notification of up to 10 recipients is advantageous for simple applications.
Text messages can be customized with macros.
• Sensor or device status can be requested by texting or calling the device.
• Configuration software needs no installation. Simply use android application from your phone after connecting the together all the component.
o The internal battery enables alerting to failed/restored power supply. Suitable for monitoring UPS and back-up generators.
o Roaming functions reduce data costs outside of the home GSM network. Suitable for automotive or marine applications.
Applications and usage examples
• GPRS monitoring of a server room without connecting to the local LAN
• Diesel generators – environment and status monitoring
• Back-up power supply systems
• ATM (Automatic Teller Machines) environment monitoring
• Cooling systems and coolers
• Technology along roads, highways, or railroad tracks
• Road surface or railroad track temperature and status
• Temperature and displacement of structures
• Storages of food or materials
• Agricultural production premises (greenhouses, granaries, etc.)
• Electricity distribution networks (transformer stations, lines)
• Remote area Solar Power Plant
• Also known as: remote environment monitoring system, monitor server rooms, computer room, network closet, temperature sensor, remote power reboot, server room monitoring.

Environmental threats in your server room can cause a lot more damage than hardware or software problems. Redundant hardware, backup tapes, UPS battery arrays, generators and other fault-tolerance measures can all be rendered useless if your server room overheats or floods. Don't ignore environmental threats – remotely manage them with G-Alert intelligent temperature sensor

• Apart from virus, spyware and network threats, the factors that adversely affect IT operation are temperature, humidity, airflows, smoke, water leak and electricity. The elements have detrimental effect on the equipment and make them sluggish, which ultimately results in the poor performance of business. With this in mind, data center environmental monitoring system seems to have very crucial role in keeping an eye on network closets, server rooms and enterprise level data center. In order to know if there is any problem happening with the server or data center, it is very important to configure your system with features such as alert notifications to received SMS or voice call alarms to notify when something goes wrong

• Various types of sensors can be used to provide early warning of trouble from these threats (i.e. temperature, water leak, Smoke, airflow, Power and many more). Understanding the technique for monitoring distributed physical threats enables the IT administrator to fill critical gaps in overall data-center security and keep physical security aligned with changing data-center infrastructure and availability goals.


• In addition environment monitoring systems also deliver real time alerting. Server room environments are highly sensitive. Heightened temperature or humidity or water ingress are serious issues requiring immediate remediation. Environment monitors can alert you to problems proactively helping you to minimize system downtime. Unexpected system downtime is incredibly costly to a data center.
Available in stock.

PRICE: N147,000

Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 11:52am On Feb 05, 2018
Our work comes with technical warranties
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 5:23pm On Mar 18, 2018
We thanks our numerous customer who patronized us through this platform.
Re: Server Room Equipment & Environmental Monitoring Systems by lotusbeta: 10:11am On Mar 19, 2018
Just migrate to Microsoft Azure. Remember you would still have to continually power these server rooms. God help you if they go off for one second. Allow Azure take care of all your information. Talk to us today.

You are already there. Let us take you further.
Lotus Beta Nig Ltd.,

Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 10:29am On Mar 26, 2018
.
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 8:26am On Apr 14, 2018
Our work comes with technical warranties..,,
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 8:41am On Apr 15, 2018
....
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 6:14pm On Apr 19, 2018
We deploy service nationwide
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 9:07am On Apr 26, 2018
Our service is excellence
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 6:46am On May 07, 2018
We deploy nationwide
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 3:59pm On Jul 04, 2018
H
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 8:15am On Jul 08, 2018
We thank God for this opportunity
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 7:26am On Aug 20, 2018
Fault detection systems device
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 10:15am On Sep 13, 2018
Fautlt detection systems
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 8:21am On Oct 18, 2018
Deployment nationwide
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 10:33am On Nov 19, 2018
Thanks u all
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 6:06pm On Dec 02, 2018
We deploy services nationwide,,..
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 2:43pm On Dec 09, 2018
Thanks


Morning
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 1:02pm On Dec 11, 2018
Thanks you for your patronage
Re: Server Room Equipment & Environmental Monitoring Systems by CNSUNWE621: 4:13pm On Feb 21, 2019
The products seems great.
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 8:33am On Mar 06, 2019
h
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 8:15am On Sep 26, 2019
Installation nationwide
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 7:01am On Apr 05, 2020
Thanks for your patronage.

Stay SAFE
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 3:24pm On May 05, 2020
Thanks for your patronage
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 4:58pm On Mar 30, 2021
we deploy nationwide.

trust us
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 3:41pm On Jun 01, 2021
Thanks for your patronage
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 8:18am On Feb 25, 2022
nationwide delivery

call for enquiry
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 7:35am On May 02, 2022
Happy new month to all our various customers

Nationwide delivery
Re: Server Room Equipment & Environmental Monitoring Systems by KlasysTech(m): 10:24am On Jul 23, 2022
Happy weekend .
.

(1) (2) (Reply)

Goat Humping On Another On Top Of A Car / Vision 2020 Electric Power Generation: Backyard Turbine System / Big Bang And Evolution Theory Are The Two Greatest Scam In Science

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 63
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.