Re: Inverter Users : Lets Have Your Experience by darocha1: 12:45pm On Aug 23, 2017
airsaylongcon:
Hi guys,
So I'm considering getting in on Alternative Energy via Inverters. Has anyone used Li-ion batteries instead of Lead acid batteries?

WE USED TO BE A DISTRIBUTOR OF LION BATTERIES SOMETIME AGO. It is a good product & worth a trial.
Goodluck
Re: Inverter Users : Lets Have Your Experience by spinola: 12:25pm On Aug 28, 2017
If you are looking for the very best 2kva inverter system on the market, look no further! The Mercury 2.4kva-Complete Inverter System is an incredible package deal, offering you everything you need to get your inverter up and running. With a one year warranty which includes installation and after sales support, you do not have to spend a fortune to get your inverter running properly. We have paired a Mercury 2.4kva inverter with two 200ah Deep Cycle batteries, which give an excellent performance as well as value for money and you can see it all working before you pay, by selecting our pay on delivery option.

Read More:

http://mercurydirect.com.ng/product/mercury-2-4kva-complete-inverter-system/

Re: Inverter Users : Lets Have Your Experience by Spectre81(m): 2:52pm On Aug 30, 2017
Who can give me information on this brand of inverter

Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 9:59pm On Sep 06, 2017
Spectre81:
Who can give me information on this brand of inverter

Simply contact me for an affordable fairly new mercury 3kva 24v pure sinewave power inverter ..

081-350-319-51

1 Like

Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 5:52pm On Sep 10, 2017
Solar accessories ;

DC breakers
MNSPD
Pro roof mounts
Battery rack
Digital Timer switch
Digital Watts meter
Solar fire resistant cables

UNI-T digital DC clamp meter
DC disconnect kit
Solar panels
Inter battery connectors cables, bus bars
Power inverters
Digital inclinometer
Compass tools

See mobile number details in profile - signature !

1 Like

Re: Inverter Users : Lets Have Your Experience by udogenius: 7:11pm On Sep 10, 2017
hi
Re: Inverter Users : Lets Have Your Experience by Adaowerri111: 7:38am On Sep 11, 2017
My Inverter gets filled withing 30minutes and drains in less than 30 mins, what could possibly be the fault? been using for more than a year, battery is okaya and inverter is powerstar
Re: Inverter Users : Lets Have Your Experience by earthrealm(m): 9:46am On Sep 11, 2017
Adaowerri111:
My Inverter gets filled withing 30minutes and drains in less than 30 mins, what could possibly be the fault? been using for more than a year, battery is okaya and inverter is powerstar

YOUR BATTERIES ARE PROBABLLY TOAST!.
you may load test them to be sure, 24v or 12v system?..the okaya i believe are sealed mf battery?.
1yr is too short for battery to fail, are the batts brand new?
something is wrong..you need a pro to review your set up..
contact yopur installer...what is he saying.......
Re: Inverter Users : Lets Have Your Experience by Adaowerri111: 10:35am On Sep 11, 2017
earthrealm:


YOUR BATTERIES ARE PROBABLLY TOAST!.
you may load test them to be sure, 24v or 12v system?..the okaya i believe are sealed mf battery?.
1yr is too short for battery to fail, are the batts brand new?
something is wrong..you need a pro to review your set up..
contact yopur installer...what is he saying.......


It was bought brand new, tried reaching him since last week, he's not available, his office is locked
Re: Inverter Users : Lets Have Your Experience by earthrealm(m): 11:28am On Sep 11, 2017
Adaowerri111:



It was bought brand new, tried reaching him since last week, he's not available, his office is locked

they MAY NOT BE BRAND NEW.
are you technical?
what load do you have on the system, how many batteries, series or parallel connection?
do you allow the batteries run down often...etc.
you need to answer all these questions b4 we can help u.
Re: Inverter Users : Lets Have Your Experience by Adaowerri111: 12:52pm On Sep 11, 2017
earthrealm:


they MAY NOT BE BRAND NEW.
are you technical?
what load do you have on the system, how many batteries, series or parallel connection?
do you allow the batteries run down often...etc.
you need to answer all these questions b4 we can help u.


deep freezer, 2 tvs, Washing machine, laptops.
I usually put off the inverter when it starts beeping
Re: Inverter Users : Lets Have Your Experience by Adaowerri111: 1:01pm On Sep 11, 2017
earthrealm:


they MAY NOT BE BRAND NEW.
are you technical?
what load do you have on the system, how many batteries, series or parallel connection?
do you allow the batteries run down often...etc.
you need to answer all these questions b4 we can help u.



It was brand new with cartons, I usually put it off when it starts beeping, used with 2tvs36", fridge, washing machine, laptops

Re: Inverter Users : Lets Have Your Experience by earthrealm(m): 2:23pm On Sep 11, 2017
Adaowerri111:



It was brand new with cartons, I usually put it off when it starts beeping, used with 2tvs36", fridge, washing machine, laptops

wow, all this load on 2 x 12v 200ah battery?!!!!.
you overloaded the battries...thats why they failed prematurely, batteries last longer if you dont drain them below 30% dod [depth of dischARGE], by the time the inverter starts beeping, its already too late, as the draw is below 30% dod.
if you still want to continue using inverters and hv the batts last longer...you need to do a load analysis & optimization

for eg 2 x 12v 200ah batt contains 4800wh
assuming 90% efficeincy this leaves you with 4320wh or 4300wh approx
@ 50% dod = 2150wh.
for ease of calculation lets assume 2000wh
so u can only power a
200w load for 10hrs
400w load for 5hrs
100w load for 20hrs etc

the load u listed is way above 400w
36'' tv shud be about 80watts, if led, n 180watts if lcd...and you have 2
washing machine is between 400w to 1000w
fridge is between 80w to 140w depending on size
laptop is 65w
fan is 80w
light bulbs...u didnt state..

thus you can see that u severly overloaded the system leading to its sudden and premature failure

4 Likes 1 Share

Re: Inverter Users : Lets Have Your Experience by Adaowerri111: 2:26pm On Sep 11, 2017
earthrealm:


wow, all this load on 2 x 12v 200ah battery?!!!!.
you overloaded the battries...thats why they failed prematurely, batteries last longer if you dont drain them below 30% dod [depth of dischARGE], by the time the inverter starts beeping, its already too late, as the draw is below 30% dod.
if you still want to continue using inverters and hv the batts last longer...you need to do a load analysis & optimization

for eg 2 x 12v 200ah batt contains 4800wh
assuming 90% efficeincy this leaves you with 4320wh or 4300wh approx
@ 50% dod = 2150wh.
for ease of calculation lets assume 2000wh
so u can only power a
200w load for 10hrs
400w load for 5hrs
100w load for 20hrs etc

the load u listed is way above 400w
36'' tv shud be about 80watts, if led, n 180watts if lcd...and you have 2
washing machine is between 400w to 1000w
fridge is between 80w to 140w depending on size
laptop is 65w
fan is 80w
light bulbs...u didnt state..

thus you can see that u severly overloaded the system leading to its sudden and premature failure
, so what do I do?
Re: Inverter Users : Lets Have Your Experience by earthrealm(m): 5:21pm On Sep 11, 2017
Adaowerri111:
, so what do I do?

said it before..get a pro near you to help you.do an energy audit
if you cant get a pro..
u can list all the loads you power the inverter with, and state how many hours on the average you power them.
also confirm on the average how many hrs of phcn you get daily.

eg freezer 140w...runs for 6hrs daily etc do same for all the loads in ur house
confirm the exact specs of your inverter and charging current if known eg 24v 2.5kva sukam inverter etc.

am almost certain your present btteries are dead, and you would hv to discard/sell them off soon
you have to reduce your load and or increase your battery bank to 4 or more...if u want ur new /future batteries to perform any better
Re: Inverter Users : Lets Have Your Experience by Adaowerri111: 5:27pm On Sep 11, 2017
earthrealm:


said it before..get a pro near you to help you.do an energy audit
if you cant get a pro..
u can list all the loads you power the inverter with, and state how many hours on the average you power them.
also confirm on the average how many hrs of phcn you get daily.

eg freezer 140w...runs for 6hrs daily etc do same for all the loads in ur house
confirm the exact specs of your inverter and charging current if known eg 24v 2.5kva sukam inverter etc.

am almost certain your present btteries are dead, and you would hv to discard/sell them off soon
you have to reduce your load and or increase your battery bank to 4 or more...if u want ur new /future batteries to perform any better


Okay sir, thank you.... I noticed without the freezer(with one tv and bulbs it goes for atleast 6hours, does that mean one of the batteries is still good?
Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 5:30pm On Sep 11, 2017
earthrealm:


wow, all this load on 2 x 12v 200ah battery?!!!!.
you overloaded the battries...thats why they failed prematurely, batteries last longer if you dont drain them below 30% dod [depth of dischARGE], by the time the inverter starts beeping, its already too late, as the draw is below 30% dod.
if you still want to continue using inverters and hv the batts last longer...you need to do a load analysis & optimization

for eg 2 x 12v 200ah batt contains 4800wh
assuming 90% efficeincy this leaves you with 4320wh or 4300wh approx
@ 50% dod = 2150wh.
for ease of calculation lets assume 2000wh
so u can only power a
200w load for 10hrs
400w load for 5hrs
100w load for 20hrs etc

the load u listed is way above 400w
36'' tv shud be about 80watts, if led, n 180watts if lcd...and you have 2
washing machine is between 400w to 1000w
fridge is between 80w to 140w depending on size
laptop is 65w
fan is 80w
light bulbs...u didnt state..

thus you can see that u severly overloaded the system leading to its sudden and premature failure

You Said it all... The said system was abused which lead to its premature failure ! He might need new set of batteries (2/4 units) , proper load isolation and energy efficient gadgets.. Most of us have our mobile number readily available online to reduce regrettable mistakes .. Cheers !

2 Likes

Re: Inverter Users : Lets Have Your Experience by earthrealm(m): 9:21pm On Sep 11, 2017
Adaowerri111:



Okay sir, thank you.... I noticed without the freezer(with one tv and bulbs it goes for atleast 6hours, does that mean one of the batteries is still good?

i dont know, cant tell from here.
you need to hv the batt load tested to check the health of the battery bank
@kiekie1 is 1 of the pros and sellers.. depending on ur location, he might be able to help.

u can start by reducing the load on the inverter to not exceed 250w at any time, do this for a wk or two and observe if there would be an improvement.

i repeat for the last time, you need some1 knowledagble to come around and audit your setup...........there is nt much i can do from the internet, there are many knowledagble installers on nairaland...simply search

1 Like

Re: Inverter Users : Lets Have Your Experience by Dreamflyin(m): 6:54am On Sep 12, 2017
Please I want to install security light using 50watts led. What system capacity will power 4 of such lightning for 6hrs at night?
Re: Inverter Users : Lets Have Your Experience by spinola: 6:08pm On Sep 13, 2017
Dreamflyin:
Please I want to install security light using 50watts led. What system capacity will power 4 of such lightning for 6hrs at night?

You can use a 150ah Deep Cycle Battery, 12v 500 watts inverter with intelligent 20a battery charger. This will give you 6 - 8 hours with 200 watts continuous load.

1 Like

Re: Inverter Users : Lets Have Your Experience by israelpalatoe(m): 8:15pm On Sep 13, 2017
spinola:


You can use a 150ah Deep Cycle Battery, 12v 500 watts inverter with intelligent 20a battery charger. This will give you 6 - 8 hours with 200 watts continuous load.

Correct. My app gave me this

Re: Inverter Users : Lets Have Your Experience by pointstores(m): 10:28pm On Sep 13, 2017
1.2kva brand new inverter plus 100ah battery 68,000 bonanza prize with 1year guarantee chargeing current 20ah call 08166117634
Re: Inverter Users : Lets Have Your Experience by Talibanis: 8:00am On Sep 14, 2017
pointstores:
1.2kva brand new inverter plus 100ah battery 68,000 bonanza prize with 1year guarantee chargeing current 20ah call 08166117634
Let's see pix and brand of inverter.
Re: Inverter Users : Lets Have Your Experience by pointstores(m): 8:24am On Sep 14, 2017
Talibanis:

Let's see pix and brand of inverter.
the inverter name is anchor is an India brand it has ups mode and inverter mode overload protection more than 200pieces available 1year warranty office in Lagos pictures will be uploaded very soon
Re: Inverter Users : Lets Have Your Experience by spinola: 6:12pm On Sep 15, 2017
Mercury Complete Inverter Systems starting from ₦95,000

mercurydirect.com.ng

Re: Inverter Users : Lets Have Your Experience by Wayne4uall(m): 10:37pm On Sep 15, 2017
Can I get one that can power a 24 inch led tv, a startimes decoder or a ps 4 and one or two bulbs and a fan for more than 10 hours and how much will it cost me




kingviny:
AFFORDABLE INVERTERS!!!

5 REASONS WHY YOU MUST OWN AN INVERTER (FUELESS & NOISELESS POWER GEN.) IN NIGERIA

• With the high cost of PHCN bill, an Inverter will help you to store energy for later use so that you can maximize your PHCN power expenditure.

• With the stress in Nigeria, you can not afford not to sleep well at night with light and fan. If PHCN power is not in supply, you can switch to inverter. Don’t join those who risk using noisy and smoky power generator overnight. They are hazardous, disturbing and very dangerous! Inverter is noiseless, fueless, smokeless and not dangerous.

• The savings made in terms of fuel and maintenance when you compare inverter use to that of power generator is very huge! With the ever sky rocketing cost of fuel and maintenance stress, you can imagine how much you will be saving.

• The money you spend in fuelling your gen. on a daily basis for 1 year is enough to buy our complete inverter solution (inverter + battery) of which the battery can last you for up to 5 years!

• By using inverter at home/office, you will be helping to reduce the gas toxins being generated by power generator users in Nigeria. Many epidemic air borne diseases can then be minimized.

OWNING AN INVERTER IN NIGERIA IS THE WISEST THING TO DO. YOU DESERVE
THE BEST, GO FOR IT NOW!

WE CAN SUPPLY YOU OUR 2.0 KVA INVERTER + BATTERY CHARGER AT A GIVE AWAY PRICE SPLASH OF N34,950 ONLY. WE WILL ADVISE YOU ON THE BEST TYPE OF BATTERY TO BUY. TO SAVE YOU A LOT OF MONEY, WE HAVE RE-ENGINEERED THIS 2.0 KVA INVERTER MODEL TO RUN ON ONLY 1 BATTERY ( 200 AH MODEL, DEEP CYCLE )

OTHER RATINGS ARE AVAILABLE.

HURRY AND ORDER NOW! WE HAVE LIMITED STOCK.
HOTLINES:- 07081516945 , 07025402410
POWERED BY:- MOMENTUM VINAY TECHNOLOGIES, LAGOS – NIGERIA
Re: Inverter Users : Lets Have Your Experience by Wayne4uall(m): 10:39pm On Sep 15, 2017
spinola:
Mercury Complete Inverter Systems starting from ₦95,000

mercurydirect.com.ng


Can I get one that can power a 24 inch led tv, a startimes decoder or a ps 4 , and a laptop and one or two bulbs and a fan for more than 10 hours and how much will it cost me
Re: Inverter Users : Lets Have Your Experience by spinola: 1:29pm On Sep 18, 2017
Wayne4uall:


Can I get one that can power a 24 inch led tv, a startimes decoder or a ps 4 , and a laptop and one or two bulbs and a fan for more than 10 hours and how much will it cost me

A 2.4 kva Modified Sine Wave inverter with two 200ah Deep Cycle Batteries will run for 10 hours or more at 400 watts continues load, if your total wattage is lower it will run longer, if it is higher the time will be less. The total cost for the 2.4Kva Complete Inverter is N269,000 all inclusive.



http://mercurydirect.com.ng/product/mercury-2-4kva-complete-inverter-system/

Re: Inverter Users : Lets Have Your Experience by calabardick(m): 6:37pm On Sep 18, 2017
spinola:


A 2.4 kva Modified Sine Wave inverter with two 200ah Deep Cycle Batteries will run for 10 hours or more at 400 watts continues load, if your total wattage is lower it will run longer, if it is higher the time will be less. The total cost for the 2.4Kva Complete Inverter is N269,000 all inclusive.



http://mercurydirect.com.ng/product/mercury-2-4kva-complete-inverter-system/

How much is your 5.5kva (96)
Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 10:07pm On Sep 19, 2017
kiekie1:
DISCOUNT ! DISCOUNT !! DISCOUNT SALES !!!!!!

TROJAN IND 17-6V industrial line flooded lead acid batteries (1202AH) ......

USA TROJAN L16-RE Premium Line Flooded Lead Acid Battery 6V (410AH)20hr Rate **.....

USA TROJAN J200-AC Signature Line Flooded Lead-Acid Battery 12V (200AH) 20hr Rate .... "NOW IN STOCK"....@130k

Solarworld mono panels 255w ,260w,265w "made in Germany" at very discounted prices......... "OUT OF STOCK"


Latest A&E model 10kva wall mount servo stab (AC input range 80V-270V)....... @105k

Must power star light inverters with charge current adjustable variable,LCD display,wall mount,remote port,load wattage display,flooded/gel/agm battery settings,battery equalisation and desulphation settings...

1kw 12v
2kw 12v/24v
3kw"4kva" 24v= 160k
4kw"5kva" 48v

EP SOLAR MPPT SOLAR CHARGE CONTROLLER 12/24/48V AUTO SELECT ;
60a @ 145k
20a @ 10k (PWM)

Programmable timer switch with LCD display 220vac 16a........ @6k

Infinitum battery desulphators 12v & 24v "NOW IN STOCK" ...@


Full river agm 12v 200a batteries @ 55k


10mm² black armoured solar panel-charge controller cables with earth/grounding flex "silver copper based & heat resistant " ... @


*AUTHORISED DEALER PRAGMATIC TECHNOLOGIES*
All our prag / cyberpower products comes with reliable warranty

*AUTHORIZED DEALER INDIAN INVERTERS / BATTERIES ... GENUS , LUMINUOS , EPSILON PRODUCTS*
All our products come with 1 year Warranty

*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty

For best affordable prices,proforma invoices valid for just 1 week, contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!

Yachi solar panels arriving soon ....

1 Like

Re: Inverter Users : Lets Have Your Experience by spinola: 8:12pm On Sep 21, 2017
mercurydirect.com.ng

Re: Inverter Users : Lets Have Your Experience by babniyen(m): 7:49am On Sep 22, 2017
Very strong Sealed Lead Acid Batteries (VRLA) available for sale.
We also have Very good UPS for sale at best prices.

CHECK US OUT
https://www.nairaland.com/3939081/sealed-inverter-batteries-cheap

We give guarantee on our products.

We are factory representative.

Call for your orders: zero8158402376

(1) (2) (3) ... (65) (66) (67) (68) (69) (70) (71) ... (166) (Reply)

How To Hack Any Wifi Network Password Using Cmd / Huawei USB Modem Unlocker - Download Here! / Post Your Computer (PC) Troubles Here.

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 62
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.