Bodeface's Posts
Nairaland Forum › Bodeface's Profile › Bodeface's Posts
1 2 3 4 5 6 7 8 9 10 (of 18 pages)
bodeface: Good Morning House. A newbie is asking, assuming the cost is not a challenge which of the Xiaomi phone will you go for (or is the best)? What is the best budget (Cost effective in relations to all round performance) Xiaomi Phone? Also, please name three top dealers in this forum which delivers problem free and at a good rate for Xiaomi Phone purchases. Appreciate all responses [/size][size=8pt] bodeface: |
bodeface:Thanks to @iheanyi4u for your comment, @Protein0 your pricing noted, I understand you are a dealer and wouldn't want to condemn any of your product, but to every Xiaomist in the house, help a newbie Xiaomi phones has a lot of variety and can be very confusing, help out on this, appreciate all. |
Good Morning House. A newbie is asking, assuming the cost is not a challenge which of the Xiaomi phone will you go for (or is the best)? What is the best budget (Cost effective in relations to all round performance) Xiaomi Phone? Also, please name three top dealers in this forum which delivers problem free and at a good rate for Xiaomi Phone purchases. Appreciate all responses [/size][size=8pt] |
@Feflo, Femi, do you have the MHB battery in stock? Thanks |
onatisi:Could you make the payment to Turkish Bank? |
Thanks to all the SMEs for all your inputs, this has reinforced my understanding, I will set it up as an array 2*3 configuration as 84V VOC, the wire run between the combiner box and the PV array is just about 5-6 meters, I sized my cable to be 6mm2 and the combiner to the Solar charger is just about 6 meters, the cable was sized to be 16mm2, this should all be adequate. @Kiekie Thanks for your input, How much is your Surge Arrestor both DC and the AC, all other items already in stock DMerciful: |
Hello SMEs Happy Sunday to everyone. I am planning on installing 6 numbers of 310W solar panels with 60A, 150V Schneider XW 60 MPPT CC, this is a phased Installation, the short circuit current of the PV is about 9A, while the max operating current is about 8.2A, the VOC is 42V and the max operating voltage is about 36V. The battery bank and Inverter operating voltage is 24V (already existing) I just want opinion from the SME on the best combination for better efficiency, from the look of things this could be 2 arrays (2 X 3PVs In series) or 3 arrays of (3 X 2PVs in series). Which do you think will be of better efficiency, appreciate all comments |
Does anyone in the house has the midnite Wizbang Jr (MNWBjr) and the standard 50mv / 500A Shunt (MNSHUNT) for sale |
mcTrinity:Suntech 310W Poly @ 80K, large purchase subject to discount. |
mcTrinity:@ mcTrinity Sorry getting back to you late, the price is 80K, let me know quantity, might be able to get better offer. |
mcTrinity:@mcTrinity I have got the SUNTECH 310W Poly if you are interested, let me know. |
chris81964:@ chris81964 Dr Sola, I appreciate your reply to my inquiries, I have been able to figure it out, I have posted the solution also on this forum, however I will keep the contact fmight be useful in the future. Thanks. I have been able to resolve this, for the record purpose while using the Schneider Conext SW4024 Inverter built-in charger only to charge the battery without solar installation with external charge controller, in the setup parameters while commissioning the unit you must adequately define the battery parameters and more importantly you must ensure that the right charging rate for battery is calculated and represented by the right percentage setting under the Charge rate parameters, otherwise you will be having F49 fault (DC Over Voltage), which might take you a while to figure it out. bodeface: |
I have been able to resolve this, for the record purpose while using the Schneider Conext SW4024 Inverter built-in charge only to charge the battery without solar installation with external charge controller, in the setup parameters while commissioning the unit you must adequately define the battery parameters and more importantly you must ensure that the right charging rate for battery is calculated and represented by the right percentage setting under the Charge rate parameters, otherwise you will be having F49 fault (DC Over Voltage), which might take you a while to figure it out. bodeface: |
Hello house, Anyone with experience on Schneider product should help out on this; Schneider Conext SW4024 Inverter tripping on F49 fault (DC Over Voltage), the battery bank is a set of eight nos of 200AH wired for 24VDC, I have monitored the charging voltage while the inverter is charging not to exceed 26.1VDC and the battery bank voltage sitting pretty at about 24.8VDC, however once the utility power is applied to the inverter after charging for about 2-3 mins will trip on F49 fault. Has anyone experienced this before? Appreciate all comments |
Barezzi, Thanks for your reply, I am just double checking if any has any bad experience using such. I can only think of the angle iron rusting if not well treated, so care is exercised in treating the iron and painting the angle iron, that's my best option since I want the under to be a car port, thanks for double checking. On Schneider product, I will say they are robust but the challenge I have with them is that everything comes independent, say for the inverter you must have the system control panel SCP (a separate unit, bought differently) to do even just the programming of the inverter thereby increasing the cost of the entire complete installation, apart from that I cant think of any other thing.... perhaps any other installer may have a say on this. Barezzi: |
bodeface:Unfortunately, couldn't get any from the house, already purchase from outside, thanks for viewing. |
Hello Team, Is there anyone / marketer that has got the Schneider Conext system Control Panel (SCP) for XW+/ SW (865-1050-01) for best price before I look outside of the group, kindly revert with your price.
|
Hello House, Thanks for your support and answers to my previous questions. Please is there any issues in using angle iron to construct solar panel support instead of the standard supports, this is a ground mounted system, the angle iron will form slots that holds each of the solar panels, is there any issues in doing this? Thanks in advance. @ Kiekie - you are right Quanta battery is not available in the market currently. |
harveyspec:Thanks Harveyspec, just called the number on their website not picked yet I will continue trying. Thanks |
Good Morning House, I need Urgently need 4 X 200AH Amaron Quanta Batteries for purchase. To all the marketers / sellers or anyone who knows where I could get this batteries - I say thank you in advance.
|
@Dmerciful, Thanks so much for your time and explanation, may be what I will do is that I will combine the two circuit and use only one inverter, the two banks are just redundant, they do same job. Just wanted to ensure there is always power available. How much is your surge protectors? Please, you missed the second part of my question: "for the combiner box must it be OEM type or can one get one locally or fabricate or is there a make shift type that could be used as I do not see so much specialty in combiner box as it looks like a small DB could be used for combining" DMerciful: |
Team, I need your assistance bodeface: |
Team DIY, I am monitoring and inspecting my proposed site for the solar panel installation and these questions arise, I need the expert advice; 1. I observed that the area where I am proposing to install has the shadow of electric wire line (small line shadow) and small portion of the electric pole shadow that pass through the place around 2:45pm (Note I have limited space to install) 2. Whats the maximum distance between the Solar panels and the Charge controller, also between the charge controller and the battery or as long the cable are properly sized it doesn't matter? 3. Is it compulsory to install the surge controller with every installation, if so what type is cheaper and effective, where could i source this, for the combiner box must it be OEM type or can one get one locally or fabricate or is there a make shift type that could be used as I do not see so much specialty in combiner box as it looks like a small DB could be used for combining. 4. If I have two banks of battery 48VDC, 4 X 200Ah with two independent 3.5KVA inverters to each bank and I want a single PV system to charge the two banks, is it possible and if possible how will the battery configuration / connection be, also from calculation and experience what wattage of PV panels will be able to effectively charge the two bank together. Thanks team for all help. |
bodeface: |
thanks |
babaegun:@Babaegun, Thanks for the comparison sheet, at face value looks like the midnite classic stands out, which agrees with what SAIPRO says, I will prefer the unit with the best tracking for the maximum power point. Thanks for the enlightenment @Babaegun @Saipro |
Saipro:@SAIPRO, you are very detail and so knowledgeable in this trade, do you have a coy, do you manage design and installation of the Solar systems, kindly let me know we might be able to do somethings together |
Team, Please, without considering the cost, which MPPT Charge controller is the best in the market among; Midnite classic solar 150 / 200, Outback FM60 /80, Tristar MPPT 60A, Schneider Xantrex 150V / 600V, Magnum, e.t.c in terms of best solar harvest, durability, flexibility, extend-ability remote accessibility and e.t.c Which maker or model is the best. Thanks |
This may work for someone! VACANCY! VACANCY!! VACANCY!!! Job summary - Electrical Engineer If you are highly skilled and experienced in Solar Energy system, Residential / commercial / industrial electrical system, residential / commercial burglar & Access control system and you are interested in being part of a new business startup kindly send your CV with traceable record of your experience to the email address below. Education - HND / OND Experience - at least 3 year related work experience Job location - Ikotun ,Lagos To apply send CVs to info@readyandsmart.com Only selected qualified and experienced personnel will be contacted. |
DMerciful: bodeface:@Dmerciful, Am a DIY guy, I am just trying to rub mind with highly experienced guys like you, I know you have been in the game for long and will love to check my calculations and equipment brands with you guys before jumping into it, appreciate all assistance. |
DMerciful:Dmerciful, Am a DIY guy, I am just trying to rub mind with highly experienced guys like you, I know you have been in the game for long and will love to check my calculations and equipment brands with you guys before jumping into it, appreciate all assistance. |
To the Solar Gurus in the house, Good Morning All! I have been following this thread for awhile and am fascinated with testimonies from those who have upgraded to RE. I am looking at upgrading my 3.5KW, 200AH, 48V inverter system to solar since power utility company has gone on strike (LOL) in my area, can you kindly advice number of solar panels and charge controller size that will charge the system perfectly, I understand that best performing devices are not the most costly at times, kindly advice the brand and the model (solar panel & CC & others) that is cheap but yet powerful (tested and trusted) and other things I might need for the Upgrade. Thanks to all, do have a great Sunday! |