| Re: Solar Energy, A Complement To FTA by bassdow: 4:07pm On Oct 25, 2024 |
TheCreatorVerse:MoNo panels are black in Color, while POLY panels are blueish in color. Of course there are other Solar panel designs BUT just stick to these popular 2. Now if what you have above is Black in color, then it's Mono |
| Re: Solar Energy, A Complement To FTA by bassdow: 4:12pm On Oct 25, 2024 |
kristien4:...but you ended up not proving to us how you got to the 100% tag |
| Re: Solar Energy, A Complement To FTA by bassdow: 4:17pm On Oct 25, 2024 |
dollarnaira:Exactly reason why until Now, I still use a mixture of Kerosene stove, and Electric stove. People have advised me tire. I kept telling then soon, Cooking gas prices would rise. I was right after all; as usual. Of course if anyOne had loaned me a Gas cylinder, I would have used GAS but wasn't willing to invest in something I knew I would drop sooner or later. Looking to build an Oil stove which would make use of different types of oil. Just don't have time yet. Wonder why You guys ain't using CNG for cooking yet ? My own is, I fear for cars using CNG, as in, I hope it's adoption doesn't go round fully as Me go dey select Cars wey I go enter. Make dem no use person do Dynamite |
| Re: Solar Energy, A Complement To FTA by freeAgent99(m): 4:17pm On Oct 25, 2024 |
adrusa:That's a completely wrong assertion/assumption. They are highly efficient in cooling. As good as the non inverter types. And even better, considering the power efficiency. |
| Re: Solar Energy, A Complement To FTA by bassdow: 4:19pm On Oct 25, 2024 |
adrusa:Such debate could be similar to AC vs DC motors. |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 4:23pm On Oct 25, 2024 |
AmakaRuby:You don't need AC cables as such in solar installation. But that's a very huge amount of AC cables in that quotation. Maybe you asked him to do some worrying large scale wiring in your house that you are not telling us. You need to give more info on what you are doing. If not, for normal solar installation no AC cables needed as such |
| Re: Solar Energy, A Complement To FTA by kristien4(m): 4:24pm On Oct 25, 2024 |
bassdow:you did not follow the discussion from the start i guess, i posted a snapshot of my growatt inverter doing i think 4729watts with 8pieces 580watts.I think last week or earlier this week. |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 4:56pm On Oct 25, 2024 |
Iinnov8:Hi, a lithium charger that charges to max 14.6v is destroying the lithium battery fast. It's not good to charge lithium that high, and that's what many don't know and they killing their battery like that and it won't last for years as expected. It's tubular and gel that can go that high. For lithium, it's advised not to go higher than 14.2 (which is even till high). Best voltage charge setting is 13.9v or 14.0v. True your lithium won't charge full, but you are sure your lithium will do 15 - 20 years with that. If your battery has editable bms, you can charge it so that 3.5v (which is 14.0v) be 100%. This is an info many Nigerian lithium dealers and installers don't know. |
| Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 5:17pm On Oct 25, 2024 |
bassdow:Have you considered using a kerosene gas cooker? |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 5:19pm On Oct 25, 2024 |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 5:21pm On Oct 25, 2024 |
Obnoxious2001:Make una come up with options ooo. Which one be kerosene gas. Is kerosene still in existence? No vex o. E don tey. Update me biko |
| Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 5:24pm On Oct 25, 2024 |
dollarnaira:Yes it's in existence. Just that the demand is low. For the kerosene gas cooker, it existed at the early stage before cooking Gas became very popular. |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 5:25pm On Oct 25, 2024 |
ask4bk:Many Nigerians? No ooo Most us are are fully aware here too. LifePO4 is regarded full from 13.7v sef. I do 13.9v though. |
| Re: Solar Energy, A Complement To FTA by swagifted(m): 5:57pm On Oct 25, 2024 |
HeavenlyBang:increase the room size and see |
| Re: Solar Energy, A Complement To FTA by Nexuspulse(m): 7:12pm On Oct 25, 2024 |
Feedback are often helpful
|
| Re: Solar Energy, A Complement To FTA by AmakaRuby: 7:13pm On Oct 25, 2024 |
ask4bk:House is wired, it is to install solar. I have inverter, battery & panels I bought |
| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 7:23pm On Oct 25, 2024 |
ask4bk:Where is your evidence? show us real life LFP battery failed because it was charged to 3.65V. The Manufacturer tested them for 1C 2.5V to 3.65V, so where your evidence it wont last long? Its Like saying those making 14.6V chargers don't know what they are doing, or the want to purposely degrade your batteries. |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 8:11pm On Oct 25, 2024 |
Dam5reey1:I follow lifepo4 contents a lot. I'm member to some lifepo4 online communities in the USA. The general consensus for top users and engineers in this area is that lifepo4 be changed at max 13.9-14.0v. Some even go lower. Some go higher. But I only shared the consensus. I asked Chatgpt now, and here's the answer they gave. Charging a LiFePO4 battery to 14.6V can be problematic because it places the battery near its maximum safe voltage, which can stress the cells and shorten the battery's lifespan. Here are some reasons for avoiding 14.6V as a charging limit: 1. Increased Stress on Cells: Charging to the upper voltage limit can push the cells close to overcharge, increasing stress and leading to premature aging. 2. Reduced Cycle Life: LiFePO4 batteries have a longer lifespan when not charged to the maximum voltage. Lowering the float charge (e.g., to 14.0V as you've set) can help maintain the battery's cycle life, potentially reaching or exceeding the 4000 cycles. 3. Minimal Capacity Gain: Charging from 14.0V to 14.6V typically only adds a few percent to the overall capacity. The slight gain in capacity does not compensate for the loss in lifespan caused by regular charging to the higher voltage. 4. Heat Generation: Charging at higher voltages can cause the battery to heat up slightly, which also contributes to wear and tear over time. Keeping the voltage lower (like 14.0V) balances capacity with longevity, making it a good choice for extending your battery's useful life |
| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:20pm On Oct 25, 2024 |
ask4bk:Isorite... USA.. ![]() Leave story evidence no dey.... What will be like cycle if i charge to 3.65V vs 3.5V Show me real life batteries in use.. not Chatgpt which realies on what people are saying. |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 8:21pm On Oct 25, 2024 |
dollarnaira:Hmmm. I bet you that 90% of lithium users in Nigeria have their inverter or solar charger set to default settings of 14.6v or higher. I've checked many lithium application systems and in all I've never seen one set correctly. I always help them by resetting it to 13.9v charge and float (we force the float though lithium don't need float, because if you don't, after your battery is charged during the day, your appliances begin to run from your battery and not from the panels). Bro, many are damaging their lithium without knowing especially as many installers don't even know, like the guy above arguing on why the manufacturer made the charger with 14.6v, asking if I know more than the company. Lol |
| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:24pm On Oct 25, 2024 |
ask4bk:How many damaged LFP batteries have you examined? |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 8:24pm On Oct 25, 2024 |
Dam5reey1:I just told you it's a SCIENTIFIC CONSENSUS in the area of lifepo4. Use your Google and search on life experiences of long time users of lifepo4 charging at high voltage like 14.6v. Don't take my silly words. Go do your research and maybe come back to tell me thank you for opening your mind. You are free to keep charging at 14.6v or even 15v if you want. Shey you need full battery. You'll get it. |
| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:33pm On Oct 25, 2024 |
ask4bk:Show here the battery that died because it was charged to 14.6V Cause all these theories does not old any waters. Battery can be charged/Discharged from 3.65V to 2.5V. This is how all Cells were tested out of factory.. Practically nothing happens after cells reaches 3.65V. current will reduce drastically once it approaches 3.5~3.65V I have not seen a video or anyone with practical test showing cell Charged to 3.65V vs Cell charged to 3.5V and capacity left after 5 years. |
| Re: Solar Energy, A Complement To FTA by bkuranga(m): 9:22pm On Oct 25, 2024 |
HeavenlyBang:Thank you so much for taking your time to provide this much info. I really appreciate 🙏. |
| Re: Solar Energy, A Complement To FTA by bkuranga(m): 9:26pm On Oct 25, 2024 |
Ferdiwar:Thank you, I will check the recommendations out. |
| Re: Solar Energy, A Complement To FTA by bkuranga(m): 9:28pm On Oct 25, 2024 |
mctfopt:I'm just super grateful for the info you guys are willing to share here. Not easy to get brain and be willing to help with it. I salute you. I will check the IVPM series out. Hopefully I can find the genuine one |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 10:36pm On Oct 25, 2024 |
Dam5reey1:Oga, shey we agreed you should keep charging your lithium to full 3.65V. I don't know else to say, since I've told you to go research. |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 10:43pm On Oct 25, 2024 |
HeavenlyBang:Nice detailing Bro. But why do you need to put on the freezer at night again? My freezer runs from 8am to 5pm. At 8am next day, freezer and contents are still frozen. |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 10:49pm On Oct 25, 2024 |
ask4bk:Well, it is a about our choices. All I know is that Samsung 26J lithium ion sheet discouraged 12.6v full charge to extend battery life. This was applied to my LifePO4 as a caution. By July next year, it will b 4yrs. It will degrade to 80% its capacity after 10 to 12years at least. So the journey of degraded lithium in still in the future where the remaining 80% will now begin another fresh journey. What a chemistry? |
| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 11:35pm On Oct 25, 2024 |
ask4bk:These are battery makers Not a random chatgpt.. did you see where Charge voltage is mentioned here. https://www.felicitysolarstore.com/understanding-the-lifespan-of-lifepo4-batteries-a-detailed-guide#:~:text=Ans%3A%20On%20average%2C%20a%20LiFePO4,Cycle%20Life%2C%20and%20proper%20Maintenance. Go and check the charging voltage on Felicity batteries, they have 15 years+ experience.. |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 7:58am On Oct 26, 2024 |
dollarnaira:Every lithium company discourages charging at 14.6v. Instead of Dam5reey1 to learn from this community he is insisting in his wrong opinion. I bought cworth 20kwh lithium battery the other day, and it clearly said to set charging voltage to 55.6v which corresponds to 13.9v. The Aurora lithium I'm selling said same. Sako, Anker, even Japanese Samsung lithium outside the country insist on same. Lithium doesn't like being charged to 100%. When you buy a new Samsung phone now, it tells you, you can charge your phone to 100% oh but we don't advice it. Every phone and laptop has a charging option to charge only to 80-85% so that your phone lasts for long. My S21 is going to 4 years now, and I always charge only to 80%. My phone still stays a whole day like new, compared to my older phones I always charged to 100% and after 2 years battery is a mess. Phones and pc lithium ion. Lithium ion and lithium phosphate should never be charged to 3.65V. |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 8:07am On Oct 26, 2024 |
Dam5reey1:Told you to go research, see wetin you go de search. Watch... https://www.youtube.com/watch?v=lEW6m-iKH8w |