| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 2:15am On Jan 17, 2025 |
mangolpupa:Firmware update on top of unofficial Voltronic OS.. Its like expecting latest Android OS update on generic android phones. |
| Re: Solar Energy, A Complement To FTA by mangolpupa: 2:21am On Jan 17, 2025 |
Dam5reey1:Erroneously assumed, mppt were generic across board until I started observing that my Sako is not pumping as much juice as anticipated based on my previous experience with Growatt. The Sako has an mppt input range of 90v - 450v while my growatt is 120v - 430v. It doesnt look like the sako mppt range is too wide or different. Could this still be a potential cause of relative inefficiency. |
| Re: Solar Energy, A Complement To FTA by mangolpupa: 2:23am On Jan 17, 2025 |
Dam5reey1:So are SRNE, Growatt official voltronic OS? |
| Re: Solar Energy, A Complement To FTA by Yashita: 3:44am On Jan 17, 2025 |
Hello house 👋🏾 I have a problem with my 8kva felicity inverter and my installer isn’t even coming to check it. It trips off load all the time. I bought 8 unit of 600W panels, only 7 was connected, 1 was broken. At 100% capacity, it supposed to give me 4.2kW but I know that it’s not possible. I’d be receiving 3.5 - 4kW but I don’t get up to 500W total wattage from it. The 4 wet batteries are starplus products. Now it doesn’t work effectively except I connect it to NEPA, but I should not be on NEPA because I’m not paying for it. I was even disconnected from NEPA which is very much ok, my solar energy system is supposed to be sufficient for me without NEPA. The installer has refused to show up. What do you advise? I’m in Lagos, in case you suggest another experienced installer and you can share their contact with me. |
| Re: Solar Energy, A Complement To FTA by mctfopt: 5:51am On Jan 17, 2025 |
Yashita:StarPlus is a low-quality tubular battery. That being said, I think you need another installer to check what the other installer did on the roof. If the 8kVA is of the Felicity hybrid type, and the VoC of the solar panel is below 50V, the 7 panels should be connected in series. Before this is done, the installer should check each individual solar panel to confirm they are okay. You should get at least 2.5kW from this setup if positioned on the south-facing side of the roof, and the roof inclination is not too steep. The best roof inclination angle is one that is almost flat. |
| Re: Solar Energy, A Complement To FTA by compunigeria: 6:07am On Jan 17, 2025 |
mangolpupa:What is the "Best PV range" rating stated for your Sako mppt? It could also because of that. My Sako hybrid ( wider range series ...30-400VDC) proved to be highly more efficient than my stand alone MPPT CC. The only issue i have with it is the interference with signals. |
| Re: Solar Energy, A Complement To FTA by EduTechTainMent: 6:13am On Jan 17, 2025 |
Dam5reey1:Thanks. Which of the sako products have the more efficient voltage range? I am considering getting both their 12v and 24v hybrid inverters. |
| Re: Solar Energy, A Complement To FTA by obinna37(m): 7:40am On Jan 17, 2025 |
Ferdiwar: |
| Re: Solar Energy, A Complement To FTA by redgem(f): 7:42am On Jan 17, 2025 |
brightk:When there's no load on the system at night, the v reduces |
| Re: Solar Energy, A Complement To FTA by Yashita: 8:06am On Jan 17, 2025 |
mctfopt:Yes, it’s the felicity hybrid type. Thank you, can you recommend a knowledgeable solar installer in Lagos? |
| Re: Solar Energy, A Complement To FTA by bbally: 8:14am On Jan 17, 2025 |
Yashita:Which area of Lagos are you? Give a call |
| Re: Solar Energy, A Complement To FTA by Jidejenson(m): 8:18am On Jan 17, 2025 |
Yashita:I'm here |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 8:32am On Jan 17, 2025 |
mangolpupa:Some: GSR Mustpower Exulted etc |
| Re: Solar Energy, A Complement To FTA by Yashita: 8:54am On Jan 17, 2025 |
bbally:Okota, I sent a mail |
| Re: Solar Energy, A Complement To FTA by Yashita: 8:55am On Jan 17, 2025 |
Jidejenson:Okota, Lagos. Please send me a mail. |
| Re: Solar Energy, A Complement To FTA by Jidejenson(m): 9:15am On Jan 17, 2025*. Modified: 7:40pm On Jan 17, 2025 |
![]() |
| Re: Solar Energy, A Complement To FTA by samir101ng(m): 9:33am On Jan 17, 2025 |
mangolpupa:You can check out their office if your based in Lagos. There contact details below: TBB Nigeria Service Center No. 12B, Alade Close, Off Balogun bus stop, Ikeja nigeria@tbbrenewable.com .08060.432610. |
| Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 11:27am On Jan 17, 2025 |
15kwh felicity lithium battery still available, #2,500,000. Call/whatsapp me on 08168986461
|
| Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 11:29am On Jan 17, 2025 |
17kwh felicity lithium battery still available, #3,000,000. Call/whatsapp me on 08168986461
|
| Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 11:30am On Jan 17, 2025 |
25kwh felicity lithium battery still available, #5,100,000. Call/whatsapp me on 08168986461 |
| Re: Solar Energy, A Complement To FTA by Joeysage(m): 1:07pm On Jan 17, 2025 |
kristien4:Please what's the difference. I got QASA 5kva wall stab. It has been a regrettable experience. The stab fluctuates so much that my ecoflow power generator's charging goes off and on. Makes clicking switching sounds sometimes. And the voltage delivery range is so inconsistent. I recently saw prag and noticed "servo" was attached to it and I'm wondering the difference between them. |
| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 1:31pm On Jan 17, 2025 |
mangolpupa:I didn't assume, something i dragged with the Engineers from factory, i already passed my observations. |
| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 1:34pm On Jan 17, 2025 |
mangolpupa:There are not Voltronic... Growatts and SRNE has different BMS protocols compared to Voltronic.
|
| Re: Solar Energy, A Complement To FTA by Valto(m): 1:52pm On Jan 17, 2025 |
Black Friday offer ![]() 24v 7.5kwh lifepo4 lithium battery + 24v 3kw hybrid inverter =1.580m 4.2kw hybrid inverter with 120A Mppt +24v 7.5kwh lifepo4 lithium battery =1.650m! 48v 6.2kw hybrid inverter with 120A Mppt + 48v 14.3kwh lifepo4 lithium battery (actual capacity 15kwh) =2.750m 48v 6.2kw hybrid inverter with 120A Mppt + 48v 16kwh lifepo4 lithium battery (actual capacity 17kwh) =3.150m 48v 16kwh lifepo4 lithium battery (actual capacity 17kwh) + 48v 10.2kw hybrid inverter with 10,000w pv capacity =3.550m 12v 3,584kwh lifepo4 lithium battery (actual capacity 3.8kwh) 680k 24v 2.6kwh,24v 7.1kwh, 24v 8kwh, 48v 14.3kwh, 48v 17kwh lifepo4 lithium battery available at heavily discounted prices Eve 280ah,REPT 314AH, SVOLT 50AH, CATL 23AH,EVE 20AH lifepo4 lithium battery cells available at discounted prices we can waybill easily to any location in Nigeria! our office Address is at BYC asaba/ibusa road near KOKA junction Asaba! whatsapp 08020574628 or telegram@ValtechEnergy
|
| Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 2:21pm On Jan 17, 2025 |
Yashita:Has this been resolved? |
| Re: Solar Energy, A Complement To FTA by kristien4(m): 3:01pm On Jan 17, 2025 |
Joeysage:i dont trust wall stabs, they are way lighter in weight compared to normal units of same capacity. That clicking sound is the relays, while servo stabs uses a different mechanism, kinda mechanical . Google the differences. I intend buying the qasa 10kva normal unit, weighs 65kg, while prag 15kva wall unit weighs 30kg. That difference dey surprise me.. |
| Re: Solar Energy, A Complement To FTA by Ferdiwar: 11:35pm On Jan 17, 2025 |
I've been using my Prag 5kva wall mount stab since 2020 and it has been a bliss. kristien4: |
| Re: Solar Energy, A Complement To FTA by Mubbin: 12:47pm On Jan 18, 2025 |
Pls house, any Sako major distributor in the house pls. I'm having issues with a 3KW sako inverter with random fault (3). When restarted everything seem normal until after some hours. I have observed for days and I concluded it's a factory fault from the inverter. Pls come to my rescue |
| Re: Solar Energy, A Complement To FTA by orkman(m): 3:02pm On Jan 18, 2025 |
https://www.nairaland.com/sakopower/posts Mubbin: |
| Re: Solar Energy, A Complement To FTA by Mubbin: 3:15pm On Jan 18, 2025 |
orkman:thanks boss |
| Re: Solar Energy, A Complement To FTA by Mubbin: 3:17pm On Jan 18, 2025 |
Sakopower:Pls house, any Sako major distributor in the house pls. I'm having issues with a 3KW sako inverter with random fault (3). When restarted everything seem normal until after some hours. I have observed for days and I concluded it's a factory fault from the inverter. Pls come to my rescue |
| Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 4:11pm On Jan 18, 2025 |
Mubbin:03 error means battery voltage is high, which may be as a result of overcharge. Check your charge settings first |