| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 7:39am On Jan 28, 2025 |
Haykay2001:You picture shows cells were discharged beyond what most people here considered as danger zone.. thats the only thing I pointed out. Average of 2.7V per cell is not a good way to Discharged LFP There is no reason to Charge above 3.45V and not reason to also discharge beyond 3.05V... You have not return the batteries yet? I still checked on a Client's installation yesterday, Settings 05 on the inverter was on AGM where cut off is 42V range and batteries are DIY LFP. As an Installer I see many things. Make we sha dey observe. |
| Re: Solar Energy, A Complement To FTA by obitobe: 7:43am On Jan 28, 2025 |
Apply series configuration to the panels and make sure to use the right gauge of wire BlueStripper: |
| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 7:54am On Jan 28, 2025 |
Haykay2001:On this issue, this has to do with SOC calibration on BMS, it simply show a behavior that your Client's battery has not seen 100% for few days. BMS and SOC is an estimate, to get more accurate SOC you must have 100% charge at least every 2 days. So your SOC will be 99% accurate. When charging and discharge LFP the capacity in and out is always different like 200AH in and 195AH out.. BMS will calculate this wrongly overtime and what you complained about will be their experience unless they get daily 100%. The screen below shows Inverter already cut off. At 47V which we set as LVD.. but guess what? The BMS was still showing 19%.. BMS type is the popular JK BMS so? because client is Off grid and solar radiation was not getting it to 100% as it supposed to.
|
| Re: Solar Energy, A Complement To FTA by Haykay2001: 8:18am On Jan 28, 2025 |
Thanks for this chief... I want to believe you are 100% right.. I want to believe so.. lately because of the dust, he said they've not been getting to 100% before the sun goes off... Would advice we get more panels and also clean the already installed ones... How many days do we need to run at 100% before the calibration would be reset pls...? And will it automatically correct it self back? Thanks. Dam5reey1: |
| Re: Solar Energy, A Complement To FTA by viperVIP: 9:05am On Jan 28, 2025 |
Good morning fam, Please as a matter of urgency, is there any smart solar installer/professional electrician in Ado-Ekiti who can attend to a troubleshooting for me this morning. The site is in Ado-Ekiti also and I will provide support remotely. Time expected to be spent should be 1-2 hours max. Kindly WhatsApp please O813768924O Thank you |
| Re: Solar Energy, A Complement To FTA by mangolpupa: 9:09am On Jan 28, 2025 |
Experienced ogas in the house, is it possible to combine 2 independent inverters (same brand & capacity) AC output without paralleling them and having them.communicate as one? |
| Re: Solar Energy, A Complement To FTA by Ifexabc: 9:13am On Jan 28, 2025 |
Good Morning.. Our product offerings include, but are not limited to, the following: JA 580 Mono Solar Panels - Bifacial 5kWh/48V BYD/Leoch Lithium Batteries 11.7kWh/48V Leoch Lithium Batteries 5kWh High Voltage Deye Batteries String Inverters-25KW/50KW/100KW/120 Goodwe brand Hybrid Inverters 5KW - 48V - single phase - Voltronic Hybrid Inverter 8 & 12kW - 48V - 3 phase - Deye Hybrid Inverter 20 & 50kW - 160V-800V - 3 phase - high voltage - Deye We believe that these high-quality products would be an excellent fit for your business. We would be thrilled to have you join our list of esteemed dealers and work together to expand the reach of these products. Please let us know if you are interested in exploring this partnership further. We also sell Perkins, MTU and MWM Gas Generators ranging from 15kva-2500kva... 580w Panels = ₦150,000 EACH (10yrs Warranty and 25yrs Lifespan)
|
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 10:00am On Jan 28, 2025 |
Haykay2001:Hmmm Money wey go buy certain Cc Inverter Battery 1 panel Growatt no be beans o |
| Re: Solar Energy, A Complement To FTA by BlueStripper: 11:00am On Jan 28, 2025 |
obitobe:Thank you so much Sir |
| Re: Solar Energy, A Complement To FTA by Haykay2001: 1:17pm On Jan 28, 2025 |
Haba na baba mii...600k+ will get u one na dollarnaira: |
| Re: Solar Energy, A Complement To FTA by Edrizz(m): 2:11pm On Jan 28, 2025 |
HeavenlyBang:I saw ur post where u loaded ur 3.3kw SRNE inverter to 2.6kw, my brother you enjoyed that privilege cos ur solar harvest is supporting the load with d major input else, that 3.3kw inverter can not perform at such level... it's something have tried bro, I also use 3.3kw high frequency inverter |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 2:48pm On Jan 28, 2025 |
Haykay2001: ![]() To you, is it affordable? Where una dey see money sef? The fact say client A fit afford am no mean say every other ones fit ooo. |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 3:07pm On Jan 28, 2025 |
Dam5reey1:You are just contradicting yourself. If you are admitting that it's normal for cells to have different voltages below 3v, then there's no need in saying people ask you to cut low power at 3v to HIDE FLAWS. You are suggesting that these people are selling batteries with flaws and that's why they ask you to cut at 3v, even though you know that's not the case. You really want to teach people things or give your opinions. That's really cool. But don't do it with languages or expressions that bring people down. You've sounded that way in many of your comments. |
| Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 3:13pm On Jan 28, 2025 |
ask4bk:Thats what you comprehend from my comment not my fault. I have also bring down JK BMS on my last post for Showing the picture, Its alright. |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 3:20pm On Jan 28, 2025 |
Haykay2001:I don't know what BMS you are using, but I've a battery at home that uses a Bluetooth BMS (not the JK everyone is using now but the one from another brand they were using before). Charging to a point that I know it's actually full, the BMS still reads 65%. So I entered the BMS settings from my phone, and changed the 100% voltage mark by just a little (eg 4.5v to 4.55v) and it adjusted back to 100%. Some BMS drift away in the SOC they show you, but it does not affect the ahs capacity reading used or voltage reading. Once you hit that low voltage mark, the battery will cut off even if your BMS is mistakenly reading 50% instead of 20 or 10%. The above was the trick I used sha. If not, invest in buying a Coulomb meter that you'll connect to your battery. I heard those don't fail in their SOC calculations. I recently got one from China that connects to my WiFi sef and I see my battery state of charge from anywhere in the world.
|
| Re: Solar Energy, A Complement To FTA by Haykay2001: 4:02pm On Jan 28, 2025 |
But na una talk say better soup na money kill am na.... ![]() dollarnaira: |
| Re: Solar Energy, A Complement To FTA by Haykay2001: 4:07pm On Jan 28, 2025 |
actually, I don't know the type of BMS that sako use on their products. but am very sure it is not Bluetooth compatible. what I wanna be sure is, if we charge the battery to 100% back to back, will it correct the SOC readings back to what it use to be boss? ask4bk: |
| Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 4:20pm On Jan 28, 2025 |
Edrizz:Not sure what you mean. If it's converting electricity from DC to AC, then it's inverting. That's quite literally what an inverter does. You seem to be assuming power from panels just flows directly to your load without the inverter doing anything? If I try that same load at night when I'm on battery (I wouldn't either, it's well above the 0.5c typical lithium cells can handle) and the inverter trips off, it's not that the inverter can't handle the load; it's because the battery can't handle that discharge amperage. |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 4:21pm On Jan 28, 2025 |
Haykay2001:As you said, we don't know what BMS they use. So we can't be sure if it'll correct itself. But there's no harm in trying what was suggested. |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 4:39pm On Jan 28, 2025 |
| Re: Solar Energy, A Complement To FTA by swagifted(m): 4:43pm On Jan 28, 2025 |
Edrizz:even if battery is full?. |
| Re: Solar Energy, A Complement To FTA by Haykay2001: 4:50pm On Jan 28, 2025 |
Abeg make una just leave me leave sako for now oo..body they hot ooo... ![]() dollarnaira: |
| Re: Solar Energy, A Complement To FTA by Edrizz(m): 6:08pm On Jan 28, 2025 |
HeavenlyBang:I don't believe that bro, I use 5.888kwh lfp battery with a Bluetooth enabled bms, the day i tried my 2.2kw electric kettle on d 3.3kw srne inverter while I was also monitoring the battery behaviour on my phone, I'm happy to tell u that the inverter shut down on d basis of an overload while on the bms app, there wasn't any warning sign |
| Re: Solar Energy, A Complement To FTA by Compliant(m): 6:18pm On Jan 28, 2025*. Modified: 6:54pm On Jan 28, 2025 |
ask4bk:Okay thank you Sir Please what size of lithium battery can I use comfortably with the 24v 5kva felicity stand alone inverter and the 4 pieces of 615w Jinko panel |
| Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 7:04pm On Jan 28, 2025 |
Edrizz:There's scientifically no difference between energy from panels and energy from battery. Both are in DC. Both need to be inverted to AC, which is what an inverter does. If your inverter can handle a load from pv supply, it can handle the same load from a battery as long as the battery is capable of it. In your case, if I had to guess, your battery just couldn't handle the load and voltage dropped below set cut-off leading to an inverter error/shut down. What error code did you get on the inverter? I'm willing to bet it's an 01, 04, or 29. |
| Re: Solar Energy, A Complement To FTA by Ferdiwar: 8:09pm On Jan 28, 2025 |
Well I've loaded my 5kw HF inverter above 4kw on several occasions. As at this night self it was loaded up to 4.9kw while boiling water with it. Edrizz:
|
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 8:34pm On Jan 28, 2025 |
Compliant:Since you have a 24v inverter, your battery has to be 24v too. Most brands stop their 24v at around 5kwh. But with DIY assemblers in here they can do 10kwh or more for you with 24v. If those panels produce 2400wh then you'll need 100a charge controller to get full juice out of your panels. Lower ones will bottleneck and limit what your panels produce into the lithium battery |
| Re: Solar Energy, A Complement To FTA by skywalker95(m): 10:33pm On Jan 28, 2025 |
Haykay2001:Thank you |
| Re: Solar Energy, A Complement To FTA by uche393: 9:26am On Jan 29, 2025 |
This relay can help in low voltage cut off
|
| Re: Solar Energy, A Complement To FTA by saint2ace(m): 9:51am On Jan 29, 2025 |
uche393:Nice Setup👍 |
| Re: Solar Energy, A Complement To FTA by Nobody: 10:07am On Jan 29, 2025 |
Hi guys. My felicity charge controller throws an “04” error-battery voltage is high. Even when the voltage of the battery is just 12.7V and not anywhere close to. 14.6V. This has happened before, but I fixed it by disconnecting the entire CC connection and connecting it to another Controller (PWM), and after a while I reconnect back. But this can be really stressful. Pleas what’s the solution? |