Re: Solar Energy, A Complement To FTA by olopan(m): 1:49pm On Jun 18, 2025
Try VMpower 1.5kVA 12V sold by Techland; I have one operating for 2 years+ now. It handles surges pretty okay.

Just ensure you have enough panels or a strong battery because of the surge if the fridge is used.

Jefferyzz:
Abeg I need 1.5kw or 2kva hybrid transformer based inverter. Any recommendations pls
Re: Solar Energy, A Complement To FTA by Ayomipoe(m): 7:42pm On Jun 18, 2025
Chief, give us an update on this matter? Was it truly a blown fuse?
kristien4:
Anyone with experience on growatt inverter. A friend of mine mistakenly did reverse polarity, and heard an explosion, inverter stopped working. I thought it was supposed to have a reverse polarity protection??
Re: Solar Energy, A Complement To FTA by swagifted(m): 8:00pm On Jun 18, 2025
deye 16kwh battery is now available for 3.4m....if you add money for 6kw deye its still cheaper than SRNE 16kwh battery...SRNE supposed humble this period
Dam5reey1:
grin SNRE will buy 3 Growatts..
Na why I dey with Deye and SRNE..
Re: Solar Energy, A Complement To FTA by Tvplanet: 10:49am On Jun 19, 2025
Compliant:
Greetings Sir.

Please I need your suggestion on the best inverter AC to buy

Also is there a good store in Abuja to buy original felicity 100 or 120 charge controller

Thanks
Haier Thermocool DC inverter
LG Dual Inverter
Hisense inverter

In that order
All available
You can DM if needed
Re: Solar Energy, A Complement To FTA by twinskenny(m): 11:21am On Jun 19, 2025
A client house nearly got burnt…

Why?
Wrong cable guage
Wrong breakers specifications
Untidy installations

Attached is the picture of the installations done by a quack installer..


Second pictures is what we did after we were called upon!

Always be careful guys… so your big Investiment won’t go down the drain

Re: Solar Energy, A Complement To FTA by mctfopt: 11:44am On Jun 19, 2025
twinskenny:
A client house nearly got burnt…

Why?
Wrong cable guage
Wrong breakers specifications
Untidy installations

Attached is the picture of the installations done by a quack installer..


Second pictures is what we did after we were called upon!

Always be careful guys… so your big Investiment won’t go down the drain
Nicely done

That's how it should be done.
Good job
Re: Solar Energy, A Complement To FTA by twinskenny(m): 12:02pm On Jun 19, 2025
mctfopt:
Nicely done

That's how it should be done.
Good job
Thanks chief


Appreciate it

God bless
Re: Solar Energy, A Complement To FTA by Pnutmillionaire: 12:07pm On Jun 19, 2025
Good morning nairalanders, please I have a 6kva deye inverter installed with a 14.3 kwh battery.
The problem is that the solar is showing 0.00w from the panels after installation.
The panels are total of 5900 watts.
Please can someone help me with a solution for this and what the problem might be.
The percentage on the battery is different from the percentage on the inverter and Im not sure the installer knows how to communicate them. Could this be the reason its showing 0.00w from solar panels ?
Re: Solar Energy, A Complement To FTA by Ferdiwar: 12:41pm On Jun 19, 2025
Start by sharing a picture of your installation as this will give insight on the components used and how the connection was done.

You also need to confirm the battery communication settings on the inverter as wrong settings will result to the issues you're facing with the battery readings.

I can assist to go over the settings with you via Whatsapp call, if it's ok with you drop your contact.

Pnutmillionaire:
Good morning nairalanders, please I have a 6kva deye inverter installed with a 14.3 kwh battery.
The problem is that the solar is showing 0.00w from the panels after installation.
The panels are total of 5900 watts.
Please can someone help me with a solution for this and what the problem might be.
The percentage on the battery is different from the percentage on the inverter and Im not sure the installer knows how to communicate them. Could this be the reason its showing 0.00w from solar panels ?
Re: Solar Energy, A Complement To FTA by twinskenny(m): 12:44pm On Jun 19, 2025
Pnutmillionaire:
Good morning nairalanders, please I have a 6kva deye inverter installed with a 14.3 kwh battery.
The problem is that the solar is showing 0.00w from the panels after installation.
The panels are total of 5900 watts.
Please can someone help me with a solution for this and what the problem might be.
The percentage on the battery is different from the percentage on the inverter and Im not sure the installer knows how to communicate them. Could this be the

reason its showing 0.00w from solar panels ?
Strange


Hope the panels are we series
Ask your installer to check on his meter what the panel is generating… before connecting to the inverter
Re: Solar Energy, A Complement To FTA by Pnutmillionaire: 1:32pm On Jun 19, 2025
twinskenny:
Strange


Hope the panels are we series
Ask your installer to check on his meter what the panel is generating… before connecting to the inverter
Yea, five in series twice.
Its showing zero watts when both dc breakers are ON, but the other pv shows 7v when one breaker is OFF and then it goes back to zero
Re: Solar Energy, A Complement To FTA by Mrreed(m): 1:46pm On Jun 19, 2025
Around 1:40pm,it was generating 5.4 from a possible 6. 3kw.
Roof is also slightly tilted towards the west
Mrreed:
Used 10 of it lastweek. As for efficiency, I can't tell yet because the battery get filled up before peak sunlight hours.
Re: Solar Energy, A Complement To FTA by twinskenny(m): 1:55pm On Jun 19, 2025
Pnutmillionaire:
Yea, five in series twice.
Its showing zero watts when both dc breakers are ON, but the other pv shows 7v when one breaker is OFF and then it goes back to zero
There is something wrong with the panel connection sir they need to go over it again
Re: Solar Energy, A Complement To FTA by Pnutmillionaire: 4:18pm On Jun 19, 2025
Ferdiwar:
Start by sharing a picture of your installation as this will give insight on the components used and how the connection was done.

You also need to confirm the battery communication settings on the inverter as wrong settings will result to the issues you're facing with the battery readings.

I can assist to go over the settings with you via Whatsapp call, if it's ok with you drop your contact.
I replied you multiple times but mod/bot keeps taking it down
Re: Solar Energy, A Complement To FTA by Drgreatone: 4:49pm On Jun 19, 2025
Creditalerts:
thanks you very much I was scared this the set up.
Pls can u show a close-up picture of how u hanged the battery?
Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 4:54pm On Jun 19, 2025
twinskenny:
A client house nearly got burnt…

Why?
Wrong cable guage
Wrong breakers specifications
Untidy installations

Attached is the picture of the installations done by a quack installer..


Second pictures is what we did after we were called upon!

Always be careful guys… so your big Investiment won’t go down the drain
Client is now paying Twice, Cheaper installation is the most expensive. Imagine not using proper sized cable to make the quotation appear cheaper.
I cant shout!, I bill you, e too cost, no wahala, next...
Re: Solar Energy, A Complement To FTA by Creditalerts: 6:40pm On Jun 19, 2025
My lithium battery stop charging when it gets to 96 pls helps
Re: Solar Energy, A Complement To FTA by Creditalerts: 6:42pm On Jun 19, 2025
Drgreatone:
Pls can u show a close-up picture of how u hanged the battery?
do u have same batteryhuhhuhhuhhuhhuhhuhhuh?
Re: Solar Energy, A Complement To FTA by NoMoreTrolling: 6:45pm On Jun 19, 2025
NoMoreTrolling:
2.5kva inverter 24v

Plus

2.5kwh battery

Used

700k

V.I Lagos
Used system still available

Get a solid 24v system for lasting medium power
Re: Solar Energy, A Complement To FTA by casualobserver: 1:16am On Jun 20, 2025
pazone:
Except they're not all brand new, at least from the one I tested.

The problem with Deriy 14.3Kwh Hithium White Battery with MCCB is the cells are not brand new. See the attached image of the QR code. How can you say cells manufactured in 2021 are brand new?! Or are these fake QR codes? Whichever it is, it's still false marketing.
The BMS (image attached) was programmed to charge at 40amps, new cells are supposed to support charging at 1c. Or are the Hithium cells in Deriy different?
In Southern Nigeria lifepo4 needs to be charged as fast as possible because of the weather, the sky is not always clear like in the north. So anyone with high PV output should be able to charge at 1c or 0.5?

One more thing is the Deriy 14.3Kwh Hithium White Battery with MCCB is not DIY friendly because the cells are welded (image attached)
It won't be easy to replace a cell if something goes wrong in the future. DIYers should have this in mind before buying Deriy battery pack. You get what you pay for but KaylaDeriy shouldn't be marketing these as brand new, they're definitely not.

Nice community you guys have here, researching this battery to get more info & Google landed me on this thread. Capacity test to follow soon, these are first observations.
Good watch below:


https://www.youtube.com/watch?v=zg_mwL--h6I?feature=shared
Re: Solar Energy, A Complement To FTA by jp130(m): 9:40am On Jun 20, 2025
Can someone dash me these batteries make I test my inverter of 6months without test?
Re: Solar Energy, A Complement To FTA by EduTechTainMent: 9:53am On Jun 20, 2025
olopan:
Try VMpower 1.5kVA 12V sold by Techland; I have one operating for 2 years+ now. It handles surges pretty okay.

Just ensure you have enough panels or a strong battery because of the surge if the fridge is used.
Pls how much did you get yours? Couldn't find it in their website
Re: Solar Energy, A Complement To FTA by Pnutmillionaire:
Is there a possibility a firmware update might be affecting my inverter's ability to see pv ?
10 590w jinko panels from fouani is showing 0 watts from pv side but working well with nepa.
The wire of 5 in series was tested and it got 240 volts.
There's also a little spark when the dc spd is turned off/on
Re: Solar Energy, A Complement To FTA by brightk(m): 3:09pm On Jun 20, 2025
Pnutmillionaire:
Is there a possibility a firmware update might be affecting my inverter's ability to see pv ?
10 590w jinko panels from fouani is showing 0 watts from pv side but working well with nepa.
The wire of 5 in series was tested and it got 240 volts.
There's also a little spark when the dc spd is turned off/on
a little spark on ur spd calls for concern. who tested the pv wires to read 240dc.. pls go over ur connections again ensure u are not puting positve wire on negative terminals.. a picture of ur connection would be helpful.. ur case just too early
Re: Solar Energy, A Complement To FTA by Pnutmillionaire: 4:01pm On Jun 20, 2025
brightk:
a little spark on ur spd calls for concern. who tested the pv wires to read 240dc.. pls go over ur connections again ensure u are not puting positve wire on negative terminals.. a picture of ur connection would be helpful.. ur case just too early
Thanks bro.
The installer tested it.
The inverter has been disconnected so I can take it to where I got it from for further tests