Re: Solar Energy, A Complement To FTA by fuckboys: 1:10pm On Jul 24, 2025
Drgreatone:
Pls whats the total VOC u get with the 4 panels?
130v -135v
Re: Solar Energy, A Complement To FTA by Drgreatone: 2:06pm On Jul 24, 2025
fuckboys:
130v -135v
Chief is it with load or at start up? What's the max u have seen. Use a felicity and i need about 150v
Re: Solar Energy, A Complement To FTA by Creditalerts: 2:14pm On Jul 24, 2025
zeestone99:
DIY with smart BMS is better. Forget all those brands of batteries
really ? 🤣🤣🤣😂😂
Re: Solar Energy, A Complement To FTA by Tdoctor(m): 2:45pm On Jul 24, 2025
Does anyone have a Victron Smartsolar for sale (preferably used)? Any trusted persons? Daalu
Re: Solar Energy, A Complement To FTA by Iinnov8: 11:41pm On Jul 24, 2025
1. Digital Timer Switch
Price: 10,500
You can use this device to set the time, duration and even date that certain devices (such as referigerator, starlink, etc) come on and go off. Particularly useful when you have to go to work or go bed, but you want those devices to come on and go off by themselves.

2. Power Meter
Price: 13,000
Use this device to see how much your appliances consume in watts. You can also input your energy bill in kwh and track how much it costs you to run an appliance on a daily, weekly or monthly basis

3. 60a PowMr MPPT Solar Charge Controller (Updated firmware version)
Price: 97,000
Comes with complimentary battery voltmeter worth 4,000

Re: Solar Energy, A Complement To FTA by Collione: 5:07am On Jul 25, 2025
Good morning. My inverter just dey show me shege. Anytime I try to change a setting for example if I go into settings and want to change the charge priority or bulk charge value. The moment I change it, it shows an error the reverts the setting.i just changed to default. This means that I can't change anything. What do I do to solve this
Re: Solar Energy, A Complement To FTA by Collione: 8:09am On Jul 25, 2025
Collione:
Good morning. My inverter just dey show me shege. Anytime I try to change a setting for example if I go into settings and want to change the charge priority or bulk charge value. The moment I change it, it shows an error the reverts the setting.i just changed to default. This means that I can't change anything. What do I do to solve this
This has been resolved
Re: Solar Energy, A Complement To FTA by mctfopt: 8:19am On Jul 25, 2025
Collione:
Good morning. My inverter just dey show me shege. Anytime I try to change a setting for example if I go into settings and want to change the charge priority or bulk charge value. The moment I change it, it shows an error the reverts the setting.i just changed to default. This means that I can't change anything. What do I do to solve this
Just to add some recommendations that could be helpful. You may want to add this to your query:

1) inverter make

2) inverter specification

3) Battery make or type and possible brand name

4) Image of the error/fault you got.

Gracias

Above, I guess, will help you get faster resolution to your issue.
Re: Solar Energy, A Complement To FTA by mctfopt: 8:19am On Jul 25, 2025
Collione:
This has been resolved
That was fast.


What was the issue?
Re: Solar Energy, A Complement To FTA by Collione: 10:38am On Jul 25, 2025
mctfopt:
That was fast.


What was the issue?
The inverter is a Firman inverter 5kva 48v transformer based hybrid while the battery is lvtopsun 51.2v 200ah. I simply reset everything by turning off the inverter and battery for a few minutes then turning them back on again. Somehow it resolved the issue. I attached some images. The first is the battery reading from the inverter while the second is from the battery when fully charged. Is this normal

Re: Solar Energy, A Complement To FTA by mctfopt: 10:57am On Jul 25, 2025
Collione:
The inverter is a Firman inverter 5kva 48v transformer based hybrid while the battery is lvtopsun 51.2v 200ah. I simply reset everything by turning off the inverter and battery for a few minutes then turning them back on again. Somehow it resolved the issue. I attached some images. The first is the battery reading from the inverter while the second is from the battery when fully charged. Is this normal
Oh, that's cool. Just like in a PC, a good restart may just be all that you need to fix some issue.
Re: Solar Energy, A Complement To FTA by 5starfx: 10:57am On Jul 25, 2025
5starfx:
I want to buy the Haisic stackable 4.2k inverter and the 8k battery. Pls guys I need your advice before I pay. Is it a good product?
Anybody?
Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 11:27am On Jul 25, 2025
5starfx:
Anybody?
That product is a Good one, we have installed and sold a few units and Good Feedback from Client so far.
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:03pm On Jul 25, 2025
Re: Solar Energy, A Complement To FTA by FordMustang: 6:29pm On Jul 25, 2025
Hello House/Gurus in the House! 👋

I'm new to the solar energy world and need your expert advice. I want to install a solar system for my store and would really appreciate guidance from experienced members here.

My Requirements:

• System Size: 3.5KVA 24V hybrid inverter

What I Need Advice On:

• Which brand would you recommend for a 3.5KVA 24V hybrid inverter? I've heard mixed opinions and want to hear from people with real experience.

• What's the best tubular battery brand I can use?

• How many batteries would I typically need for this setup?

• What brands of charge controller will give me the best performance and longevity?What wire gauge (mm²) should I use for:

• What mistakes should I avoid as a beginner? Any components I shouldn't cheap out on?

Thanks in advance for sharing your experience and wisdom! Any advice from the gurus here would be greatly appreciated. 🙏

Looking forward to learning from your real-world experiences!
Re: Solar Energy, A Complement To FTA by Techsinnovative: 7:30pm On Jul 25, 2025
FordMustang:
Hello House/Gurus in the House! 👋

I'm new to the solar energy world and need your expert advice. I want to install a solar system for my store and would really appreciate guidance from experienced members here.

My Requirements:

• System Size: 3.5KVA 24V hybrid inverter

What I Need Advice On:

• Which brand would you recommend for a 3.5KVA 24V hybrid inverter? I've heard mixed opinions and want to hear from people with real experience.

What's the best tubular battery brand I can use?

• How many batteries would I typically need for this setup?

• What brands of charge controller will give me the best performance and longevity?What wire gauge (mm²) should I use for:

• What mistakes should I avoid as a beginner? Any components I shouldn't cheap out on?

Thanks in advance for sharing your experience and wisdom! Any advice from the gurus here would be greatly appreciated. 🙏

Looking forward to learning from your real-world experiences!
First mistake is the @ bolded. Forget Tubular/lead acid batteries. Think in terms of Lithium batteries. They provide way more storage density at the same cost, and will also outlast both Tubular & lead acid batteries
Re: Solar Energy, A Complement To FTA by CuteMaro(m): 8:27pm On Jul 25, 2025
FordMustang:
Hello House/Gurus in the House! 👋

I'm new to the solar energy world and need your expert advice. I want to install a solar system for my store and would really appreciate guidance from experienced members here.

My Requirements:

• System Size: 3.5KVA 24V hybrid inverter

What I Need Advice On:

• Which brand would you recommend for a 3.5KVA 24V hybrid inverter? I've heard mixed opinions and want to hear from people with real experience.

• What's the best tubular battery brand I can use?

• How many batteries would I typically need for this setup?

• What brands of charge controller will give me the best performance and longevity?What wire gauge (mm²) should I use for:

• What mistakes should I avoid as a beginner? Any components I shouldn't cheap out on?

Thanks in advance for sharing your experience and wisdom! Any advice from the gurus here would be greatly appreciated. 🙏

Looking forward to learning from your real-world experiences!
You can start with stating your budget. I am sure with that people can advise you properly. Goodluck!
Re: Solar Energy, A Complement To FTA by Tdoctor(m): 9:17pm On Jul 25, 2025
Tdoctor:
Does anyone have a Victron Smartsolar for sale (preferably used)? Any trusted persons? Daalu
Anyone with a victron mppt? Are victron mppts banned on this thread? sad
Re: Solar Energy, A Complement To FTA by Collione: 10:39pm On Jul 25, 2025
Whenever I connect my Firman inverter to the lvtopsun battery and then turn on gbf BMS function, the inverter stops supplying power instantly all my light goes off unless I turn off the BMS function. I need help resolving this please
Re: Solar Energy, A Complement To FTA by Ferdiwar: 5:30am On Jul 26, 2025
This is something that comes up once in a seriously long while, so don't expect a fast response.

You can check online platforms like jiji for a used listing or a local shop within you location for a possible buy.

Tdoctor:
Anyone with a victron mppt? Are victron mppts banned on this thread? sad
Re: Solar Energy, A Complement To FTA by mctfopt: 7:59am On Jul 26, 2025
Tdoctor:
Anyone with a victron mppt? Are victron mppts banned on this thread? sad
People with Ferrari are not many grin
Re: Solar Energy, A Complement To FTA by ask4bk(m): 8:58am On Jul 26, 2025
CuteMaro:
Update from mrreed's battery.

Actual capacity is 320 ah more than the 314 ah quoted.

At that price this is the best deal you can find anywhere.


Thanks to everyone that has contributed one way or another on this forum, I was able to set up my inverter parameters successfully through the knowledge acquired here for free (My installer is more of an old-school guy but did a very neat and impressive job)
What wire size did u use from battery to inverter?
Since you using 24v system it'll be cool you use 2awg size coz of high amps if you one day use a high inductive device on your system like pump or AC or iron. You could draw 80-120a. But if you don't use any of these then 16-25mm 3-4awg that you seem to be using could go.