Solar Energy, A Complement To FTA - Satellite TV Technology (2131) - Nairaland
Nairaland Forum › Entertainment › TV/Movies › Satellite TV Technology › Solar Energy, A Complement To FTA (3497588 Views)
1 2 3 ... 2128 2129 2130 2131 2132 2133 2134 ... 2418 Reply (Go Down)
| Re: Solar Energy, A Complement To FTA by bassdow: 8:10pm On Aug 10, 2025 |
Malquisoft:is your powMr inverter Hybrid ? |
| Re: Solar Energy, A Complement To FTA by Techsinnovative: 8:29pm On Aug 10, 2025 |
bassdow:I think you misunderstand the reason for this thread, it's for sharing experience and knowledge. Are you speaking from experience in this particular matter? If so your experience would be helpful, if not it really doesn't help as it's just theory. I understand the part of solid state heating elements stressing an inverter that depends on mosfets for the DC - Ac conversion stage, especially as it's a 24v inverter, hence it has to deal with high current to achieve it's target output. Even though this may be a beating on the inverter it will handle it. It currently handles an electric kettle in the morning (1800 watts)- 3 session, 1 hp pumping machine. However, I understand that the above items draw on the inverter is short, electric kettle- 10 mins max, pumping machine 30mins max. In the case of cooking it most likely will be longer, hence my original request for advice on energy efficient options. By the way I have 2 ajebo inverters, one for redundancy ![]() |
| Re: Solar Energy, A Complement To FTA by Techsinnovative: 8:33pm On Aug 10, 2025 |
Dam5reey:I strongly disagree. Here's this guy with a 12v 1500watt chinko using an induction cooker https://www.youtube.com/watch?v=mEareS214HM |
| Re: Solar Energy, A Complement To FTA by Techsinnovative: 8:35pm On Aug 10, 2025 |
Malquisoft:Am thinking along the line of an induction cooker, thanks |
| Re: Solar Energy, A Complement To FTA by Valto(m): 8:50pm On Aug 10, 2025 |
bassdow:his hybrid inverter can comfortably carry any load less than 3000w, Sunfield is not mediocre, it is marketed by Welion company. |
| Re: Solar Energy, A Complement To FTA by Valto(m): 8:54pm On Aug 10, 2025 |
bassdow:hybrid inverters is the present and the future. there are stronger brands like DEYE.. |
| Re: Solar Energy, A Complement To FTA by mctfopt: 9:17pm On Aug 10, 2025 |
Dam5reey:My inverter is 4kw Schneider I run up to 2500w with while using airfryer with AC and freezer on. Wouldn't recommend it though ![]() |
| Re: Solar Energy, A Complement To FTA by FEGEITOK: 9:23pm On Aug 10, 2025 |
favouredbymercy:If it trips off, I allow the battery to discharge a bit through usage and then you can turn the breaker on again, failing which you will simply run down your battery. Or discover that the remaining runtime has been severely limited |
| Re: Solar Energy, A Complement To FTA by Ferdiwar: 10:16pm On Aug 10, 2025 |
I use both the infrared (4in1) cooktop and induction (single burner) cooktop on my 5kw hybrid inverter depending on the pot I'm using at that time. I even used the infrared cooktop to boil rice this evening, and have been using them since I installed the inverter 2years ago. The biggest burner of my infrared draws around 2.5kw max, while the induction cooktop draws less than that. Techsinnovative: |
| Re: Solar Energy, A Complement To FTA by Ferdiwar: 10:22pm On Aug 10, 2025 |
Is the 63amp breaker AC or DC? Also confirm the voltage rating of the breaker as if it is way higher than the battery rating, then nothing will happen whenever a high voltage is sent to the battery. favouredbymercy: |
| Re: Solar Energy, A Complement To FTA by litaninja(m): 10:25pm On Aug 10, 2025 |
| Re: Solar Energy, A Complement To FTA by Fremlin: 1:32am On Aug 11, 2025 |
Techsinnovative:
|
| Re: Solar Energy, A Complement To FTA by favouredbymercy: 2:48am On Aug 11, 2025 |
Ferdiwar:It is DC breaker. Here is the type. Please if this is not the best option for it, can you please direct me to a more appropriate one? Thanks for your reply.
|
| Re: Solar Energy, A Complement To FTA by favouredbymercy: 2:50am On Aug 11, 2025 |
FEGEITOK:Please I would like to know the type of breaker you are using. Thanks, because for now, replacement of CC is not in view |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 6:35am On Aug 11, 2025 |
Jefferyzz:Yes sir. Exactly same thing. Its plenty on aliexpress too with different names. |
| Re: Solar Energy, A Complement To FTA by Allem(m): 6:55am On Aug 11, 2025 |
Fremlin: |
| Re: Solar Energy, A Complement To FTA by ajabani4allah(m): 7:01am On Aug 11, 2025 |
bassdow:Welldone bro, I love this your energy management consciousness, this has always been my plan in this RE journey, but do people still use this type of your antenna in this era of smart/android TV( there is even SPL now solar smart TV with In build battery and solar panel) or is that not antenna for local stations? |
| Re: Solar Energy, A Complement To FTA by ask4bk(m): 7:14am On Aug 11, 2025 |
bassdow:As pros it'll be cool we stop using HYBRID as a term here to refer to HIGH FREQUENCY inverters. It confuses new people here who are learning about electricity and solar renewable energy. It'll make people think that low frequency inverters can't be hybrid whereas many low frequency inverters are hybrid. What makes an inverter hybrid is simply that it has ability to use multiple power sources together - PV, battery, grid and/or generator. Hybrid features: PV + Battery + Grid/Gen integration in one unit. Bi-directional battery charging (charges battery from solar, grid, or gen). Priority settings (e.g., solar → battery → grid, or grid → battery → solar). Grid-tie + Off-grid operation in the same unit Automatic source switching without interruption (UPS function). All felicity IVPM inverters for example are low frequency hybrid inverters. |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 8:37am On Aug 11, 2025 |
favouredbymercy:I have. My logical reason for that was that the set float voltage or maximum voltage on the CC was higher than the maximum BMS voltage. So the BMS trips, the cells voltage drop just enough to restart the BMS and the cycle repeats. Solution Since I use a battery monitor that plots real time graph of voltage and current, I studied the rippling voltage, took note of the voltage the battery drops to before restarting, and then adjusted my float voltage to that value. The ripples stopped. I use a sachet inverter that didn't or can't give you codes, rather it was going off and on. That's how I even knew something was wrong. That sachet inverter is quite rugged from my experience. |
| Re: Solar Energy, A Complement To FTA by Paschal007: 8:42am On Aug 11, 2025 |
Mrreed:I have a 24v system with 2 tubular batteries and I want to upgrade to lithium. My installer is recommending Taico 5kwh but... Anyways, is my 3kva felicity inverter compatible with this 7.1kwh and can they communicate or will the settings be done manually? Thank you |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 8:48am On Aug 11, 2025 |
FEGEITOK:For those going for cells, please read the documents well. I've noticed that sellers or manufacturers often quote cycles based on a specific SoH. For instance cell A can be 8000 cycles @70% SoH, while cell B is 6000 cycles @80% SoH. This doesn't inherently mean cell A has more cycles than cell B, nudging you to think cell A is better than B. It's all marketing gimmicks |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 9:09am On Aug 11, 2025 |
Trippledots:Baba try they communicate ooo .Most of your expressions are too formal. SoH Inherently Nudging A simple term communicates better. |
| Re: Solar Energy, A Complement To FTA by Fremlin: 9:13am On Aug 11, 2025 |
[quote author=Allem post=136414741][/quote]Omo... Thanks chief, Guess I will have to look for another |
| Re: Solar Energy, A Complement To FTA by RickyM(m): 10:12am On Aug 11, 2025 |
Trippledots:At the end of the day if all other factors are constant and total energy output over the cell’s lifespan is put into consideration…Cell with 8000 cycles @ 70% State Of Health total energy output during its lifespan is more than cell with 6000 cycles @ 80% State Of Health. |
| Re: Solar Energy, A Complement To FTA by SaintUlot: 11:23am On Aug 11, 2025 |
SaintUlot:Optimise your solar installation, substitute buying fuel with your solar installation. |
| Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 11:26am On Aug 11, 2025 |
15kwh 48v felicity lithium battery available.
|
| Re: Solar Energy, A Complement To FTA by Mrreed(m): 11:48am On Aug 11, 2025 |
You only have to change your bulk and float to 28v on your inverter and you are good to go. Paschal007: |
UPS Back-up, Also A Complement To FTA • FTA Frequency • Cctv Installation A Complement To Fta And Solar Energy • 2 • 3 • 4
Free To Air Satellite Tv General Thread
Viewing this topic: 1 guest(s)

there are stronger brands like DEYE..