| Re: Solar Energy, A Complement To FTA by Greenodds: 8:23am On Jan 17 |
dollarnaira:Person wey name em self fuckboy, you think say e dey normal? He can quote me till eternity but I no dey waste energy on these Kain people. |
| Re: Solar Energy, A Complement To FTA by Gshems: 10:11am On Jan 17 |
Up for sale 60a powmr charge controller 80k New 12v 3000w sachet inverter 80k 12v 1600w sachet inverter 55k 12v 100a joykoo lithium battery only 26 cycles bought in December . 200k. Quote me if you are interested. Selling cos I Don port to hybrid inverter and bigger battery |
| Re: Solar Energy, A Complement To FTA by Haykay2001: 10:34am On Jan 17 |
Which brand of 24v did you pair with your battery chief? fuckboys: |
| Re: Solar Energy, A Complement To FTA by fuckboys: 11:14am On Jan 17 |
Haykay2001:I went for haisic 4.2. Wanted to go for bread but bread is 3.4 as against haisic 4.2 in same price range. |
| Re: Solar Energy, A Complement To FTA by Haykay2001: 11:16am On Jan 17 |
My 1 kobo on the above setup, DO NOT USE IT FOR YOUR AC ooo if that what you wanna settle for.. And if you rili wanna use your AC, close eyes and go for 48v system.. Budget abt 4.5M and above to enjoy your appliances. Greenodds: |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 1:06pm On Jan 17 |
osayuwamwen:Running a pump for 3hrs is no joke. That's a huge amount of energy. That is roughly 3000w surge and 2000w continuous. There is huge difference between theory and practical. Why not replace the pump if the factor is less? Spend wisely. |
| Re: Solar Energy, A Complement To FTA by CuteMaro(m): 1:55pm On Jan 17 |
Greenodds:If you have 1.5m and can step it up a little to 1.8m, then go for 24v. Haisic hybrid inverter 24v 4.2kva 350k ish 24v 7 or 8kwh frm Mrreed here 800-900k ish 4 units of 550w Jinko solar panels 400k ish Installation plus materials 150k ish |
| Re: Solar Energy, A Complement To FTA by CuteMaro(m): 1:58pm On Jan 17 |
osayuwamwen:Instead of pairing the below battery at almost 1m with less efficiency, why not go for Mrreed's 8.2kwh 24v at 900k? |
| Re: Solar Energy, A Complement To FTA by Greenodds: 2:09pm On Jan 17 |
Haykay2001:Thank you very much |
| Re: Solar Energy, A Complement To FTA by Greenodds: 2:11pm On Jan 17 |
CuteMaro:Seems this is what I'll go for. Thank you. |
| Re: Solar Energy, A Complement To FTA by osayuwamwen(m): 2:47pm On Jan 17 |
I think replacing the pump will cost more, solar pump is expensive, and to replace pump wen never spoil is like a waste of money lemme just be managing the pump with generator for now till e spoil, my area the voltage is very low that it cannot even pick a stab not to talk of pump. But two 12v 314ah lifep04 battery if enough to power power my house my load is not more than 500watt at night I want to keep my refrigerator on always? dollarnaira: |
| Re: Solar Energy, A Complement To FTA by osayuwamwen(m): 3:10pm On Jan 17 |
The money is not readily available, am buying one first and later add up another one beside 900k big to spend once, I don't tink I can spend it once on 1 battery 😅 CuteMaro: |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 3:10pm On Jan 17*. Modified: 3:56pm On Jan 17 |
osayuwamwen:I didn't mention solar pump. Replace with a lower one...if you know the depth. |
| Re: Solar Energy, A Complement To FTA by Gshems: 6:19pm On Jan 17 |
Gshems:available |
| Re: Solar Energy, A Complement To FTA by chosen124: 7:50pm On Jan 17 |
Gshems:Picture of 3000w satchet inverter |
| Re: Solar Energy, A Complement To FTA by fuckboys: 8:23pm On Jan 17 |
3000w 12v inverter?. There should be no business between 12v and anything above 2000w cos that's over 200amps damn. |
| Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 8:48pm On Jan 17 |
fuckboys:Tbf I doubt they're actually loading it with 3000w. It's just better to have a higher rated inverter, so it's less stressed. |
| Re: Solar Energy, A Complement To FTA by durodee(m): 8:49pm On Jan 17 |
Max solar voltage the Cc can take is 145v, hence max of 3 x400w panels in series in reality. You can decide to parallel another 3 but the harvest of that CC is capped at 1650w, hence almost 800w will be wasted. Unless you want to add another Cc, you may be limited to maximum of 4 x400w panels at 2S2P. osayuwamwen: |
| Re: Solar Energy, A Complement To FTA by shoesaffairs(f): 9:19pm On Jan 17 |
eghos12:Please where can I get this Haisic? Original one |
| Re: Solar Energy, A Complement To FTA by shoesaffairs(f): 9:37pm On Jan 17 |
Good evening. Please what total wattage of panel will be enough for a 4.2kva inverter paired with 8kwh lithium battery? What is the cost of 600watts monocrystalline panel in lagos and where can I get them? (Not bifacial please) Can this 4.2kva assembly power a surface pumping machine? (once in a while pumping. I don't know the capacity of the machine though) Can I get this 4.2kva assembly with a 1.5m budget including panel and installation in lagos? If yes, please recommend brand. Thank you for your time and response |
| Re: Solar Energy, A Complement To FTA by fuckboys: 9:38pm On Jan 17 |
HeavenlyBang:but the more you load and inverter the better it's inverting efficiency. Infact inverters are more efficient at 70% loads and above. |
| Re: Solar Energy, A Complement To FTA by micxwell(m): 10:11pm On Jan 17 |
osayuwamwen:Lol. Why not. Spend this money Gee🤣 |
| Re: Solar Energy, A Complement To FTA by eghos12(m): 10:30pm On Jan 17 |
shoesaffairs:Big solar shops has it across Lagos |
| Re: Solar Energy, A Complement To FTA by eghos12(m): 10:41pm On Jan 17 |
shoesaffairs:First question to charge 8kwh you need to fill up the 4.2kva( max PV is 5000w) inverter. Hence you need 8 pieces of 600+ panels. Second question. Mono facial panel may be hard to get this period because marketers and producers are majorly making bi facial panels. If your building walls cannot carry weight is when you should be looking for mono facial. Also bafical 600+ are sold from 120-135(founani store ) to confirm price. Third question yes as long as it is 1hp to 1.5 hp ( I can be corrected though) Fourth question 8kwh battery+ 4.2kw inverter+ 8pieces of 600+ panel and installation will be above 1.5. |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 11:57pm On Jan 17 |
osayuwamwen:A battery with Bluetooth and an app is a high priority for me. I'ld advice you do too. |
| Re: Solar Energy, A Complement To FTA by abuzz33: 2:01am On Jan 18 |
dollarnaira:1.5hp is 1,200W not 2,000W. Surge is 2-3x or 2.4-3.6KW. So your inverter must be able to handle at least 4KW just for the pump to start. Your solar production at peak sun must be at least 1.5KWh or your battery must have at least 4KWh available if you are running it for 3 hours. Unless you have a very deep borehole or a very high tank stand, like recommended best to go for a 1HP submersible pump if you want to run it with the 3.5kw inverter you mentioned. A 1 hp pump at most needs 2.2KW starting power and 745W running power. |
| Re: Solar Energy, A Complement To FTA by bassdow: 2:31am On Jan 18 |
Greenodds:no too use people nairaland display names judge dem Ooo. Some get responsible name BUT are not responsible and viceVersa. e get another wey name contain Big, come still contain Problem and ... |
| Re: Solar Energy, A Complement To FTA by bassdow: 2:32am On Jan 18 |
Trippledots:why if I may ask ? |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 5:50am On Jan 18 |
abuzz33:Is the above on paper via google or you personally run one? |
| Re: Solar Energy, A Complement To FTA by Gshems: 7:02am On Jan 18*. Modified: 10:30am On Jan 18 |
Up for sale 12v 1600w sachet inverter 55k 12v 100a joykoo lithium battery only 26 cycles bought in December . 200k. 12v 20a lithium battery charger 42k Quote me if you are interested. Selling cos I Don port to hybrid inverter and bigger battery |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 8:16am On Jan 18 |
bassdow:For monitoring of the battery level, other parameters. Some can also show remaining time to 0% soc based on running load. |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 8:17am On Jan 18 |
Gshems:Can the charger do 24v? |