| Re: Solar Energy, A Complement To FTA by fuckboys: 8:53pm On Jan 23 |
idsolar:okay thanks, I'll look around for a good deal on it |
| Re: Solar Energy, A Complement To FTA by bassdow: 9:26pm On Jan 23 |
adimx:those specs are for Toys. I don tell you before make you abort. Few others don tell you same. I know say even you sef no get confidence hence reason you come dey |
| Re: Solar Energy, A Complement To FTA by oluchibabe: 9:56pm On Jan 23 |
AyobamiOluwole: Obnoxious2001:Guys, Thanks for your response. Total PV installed xapacity is 8,750W Yes, Inverter overload error. But my thinking is that a 3000W Cooker or 1.5Hp pump should not overload a 5Kva inverter or run down battery of my size immediately or trigger two units of 200A BMS cut-off? Do l need to increase inverter size or add another to it? Inverter has been shutting down for sometime now, even when weather was good. What is the best way for me to fund out what my inverter generates, l dont have those equipment like NCV Meter |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 10:26pm On Jan 23 |
oluchibabe:Check inverter and battery terminals. |
| Re: Solar Energy, A Complement To FTA by AyobamiOluwole: 1:08am On Jan 24 |
oluchibabe:The problem here is that you are running more load than what your inverter can take or carry. This is something I pointed out to you b4 now. Also, that your inverter is rated 5Kva doesn’t mean it’s actually 5Kva. When you factor in Power factor and Efficiency, its real usable power rating could be 3.5Kva to maybe 4Kva. I don’t think you’ll be cooking for 24hours using a 3Kva Cooker or pumping water for 24hours using 1.5hp, but anytime you intend to do that, turn off your other heavy appliances in the house. Then if you don’t want to go through that stress of always running to turn off your other appliance every now and then during such heavy usage, then go for a higher rated inverter that can chest everything at once. |
| Re: Solar Energy, A Complement To FTA by Mrreed(m): 6:15am On Jan 24 |
08131199386 johnchins: |
| Re: Solar Energy, A Complement To FTA by Mrreed(m): 6:16am On Jan 24 |
870k shoesaffairs: |
| Re: Solar Energy, A Complement To FTA by oloet: 6:57am On Jan 24 |
fuckboys:that nice |
| Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 8:13am On Jan 24 |
oluchibabe:1. Take a picture of the inverter specs label for us 2. Take a screenshot of your battery cell voltages for us 3. Take screenshots/pictures of both your battery and inverter undervoltage settings This isn't a PV issue. A 26kwh battery and your inverter are enough to handle those loads without PV at all. Your inverter is either overrated, or your undervoltage points are much higher than necessary, or you have bad cells in your battery. |
| Re: Solar Energy, A Complement To FTA by Machiny: 10:31am On Jan 24 |
oluchibabe:I had similar experience at a time, if heavy load is powered power goes off. Was told to open my battery and check each of the cell if the nuts are tight, behold one of them was loosed. Since your ba3 us a DIY you can check if any of the screws are loosed |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 11:16am On Jan 24 |
Machiny:Wahala Terminals. But can he open it up to check? |
| Re: Solar Energy, A Complement To FTA by Ferdiwar: 11:34am On Jan 24 |
First of all let's start with the basics. 1. What's the make of your inverter? 2. What is the total wattage of your loan on the inverter before the sumo or cooler was turned on? 3. Does the inverter go off only when the stated 2 load are powered on? 4. What is the size of your cables from the battery to the inverter and from the inverter to your house control switch? I also use a 5kw inverter and sometimes run the inverter to over 4.5kw with no issues even at night when it's fully running on the battery. oluchibabe: |
| Re: Solar Energy, A Complement To FTA by sofdoc1: 1:09pm On Jan 24 |
omotoda:Thanks for the reply. But I don't want to get a local battery. Do you know of any imported 10kwh battery priced at 1.7 mil |
| Re: Solar Energy, A Complement To FTA by RickyM(m): 1:14pm On Jan 24 |
Edrizz:The current limiter you’re referring to, I hope it’s not AVR? Because it’s efficiency is nothing to write home about, even when I’m consuming 200W+ from my inverter the AVR I have still shows 0.0 on the current side and that’s definitely wrong for a 200W+ load. But if there are other ones please let me know |
| Re: Solar Energy, A Complement To FTA by RickyM(m): 1:16pm On Jan 24 |
ajabani4allah:I’ve searched but all I’m seeing is AVR |
| Re: Solar Energy, A Complement To FTA by RickyM(m): 1:17pm On Jan 24 |
Trippledots:It requires a WiFi to limit the load or for initial set up? |
| Re: Solar Energy, A Complement To FTA by RickyM(m): 1:17pm On Jan 24 |
Obnoxious2001:200w load each to three different rooms |
| Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 1:58pm On Jan 24 |
sofdoc1:Deriy has a new 10kwh model that's under 1.5m. |
| Re: Solar Energy, A Complement To FTA by Machiny: 2:28pm On Jan 24 |
dollarnaira:it's not the cell he is opening but the box housing the cells, and the nuts used in tighting the bus bar to the battery. |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 3:14pm On Jan 24 |
Machiny:I know bro. Some do not own a screw driver sef not to talk of this. |
| Re: Solar Energy, A Complement To FTA by jikaseo(m): 3:36pm On Jan 24 |
Please are the batteries still available and where’s your location pls? Haykay2001: |
| Re: Solar Energy, A Complement To FTA by jikaseo(m): 3:38pm On Jan 24 |
07034819782 Mandate1: |
| Re: Solar Energy, A Complement To FTA by jikaseo(m): 3:42pm On Jan 24 |
Abeg which brand of battery is at that price? I’m looking to get one. mctfopt: |
| Re: Solar Energy, A Complement To FTA by adimx(m): 3:49pm On Jan 24 |
mctfopt:How many kw of this soft starter will be able to handle 1hp pumping machine on 3kw 12v inverter setup with 3.6kwh LFP battery?
|
| Re: Solar Energy, A Complement To FTA by jikaseo(m): 3:54pm On Jan 24 |
How much sir? justcallmenuel: |
| Re: Solar Energy, A Complement To FTA by jikaseo(m): 4:08pm On Jan 24 |
How much is the 10.2kwh? justcallmenuel: |
| Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 4:08pm On Jan 24 |
oluchibabe:The 5kva inverter has no allowance for surge and other peripheral appliances that's are running. If the load ia reduced does it work well |
| Re: Solar Energy, A Complement To FTA by adimx(m): 4:37pm On Jan 24 |
sofdoc1:Deriy 14kwh LFP is within same amount and from capacity test done by Solaris surge, the battery is complete. |
| Re: Solar Energy, A Complement To FTA by osayuwamwen(m): 4:52pm On Jan 24 |
Has anyone use this inverter brand I heard it can work with or without a battery, and can it power a 1.5hpower submersible pump effectively? How durable is it?
|