Solar Energy, A Complement To FTA - Satellite TV Technology (2257) - Nairaland
Nairaland Forum › Entertainment › TV/Movies › Satellite TV Technology › Solar Energy, A Complement To FTA (3414342 Views)
1 2 3 ... 2254 2255 2256 2257 2258 2259 2260 ... 2397 Reply (Go Down)
| Re: Solar Energy, A Complement To FTA by Drgreatone: 8:45am On Feb 03 |
Abeg show us workings. Lets see ur power house sir 😁😁 KA24DETT: |
| Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 9:13am On Feb 03 |
Meklex:I have a 195L Hisense freezer that draws 800w startup for a few seconds and then drops to ~110w. It's on for 7h30m daily (9-16:30) and averages 790wh across that period. |
| Re: Solar Energy, A Complement To FTA by Unfaized: 9:42am On Feb 03 |
sofdoc1:It's ok since you've done your research & are satisfied. It was just a piece of advice. |
| Re: Solar Energy, A Complement To FTA by RickyM(m): 9:43am On Feb 03 |
bassdow:Thanks but these are of no help as I’m using a 24V system not 12V and these are modified sine wave which means they can’t power even an inverter freezer that consume less than 90W so they won’t work for what I need. |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 9:46am On Feb 03 |
Meklex:Aeon 100L 89w |
| Re: Solar Energy, A Complement To FTA by capnies: 10:33am On Feb 03 |
I fuckboys:JUMIA KONGA KARA ETC |
| Re: Solar Energy, A Complement To FTA by capnies: 12:18pm On Feb 03 |
@Valto, mrreed Please do you have JBD smart BMS 8s 100A with communication port CAN UART etc |
| Re: Solar Energy, A Complement To FTA by Drgreatone: 1:48pm On Feb 03 |
Satchet inverter that some of us have bin using way longer than 6mths. Get original and the pure sine wave forms and u wud be fine. Odimbannamdi and Valto sell such here oweniwe: |
| Re: Solar Energy, A Complement To FTA by Drgreatone: 1:57pm On Feb 03 |
fuckboys:Order 6mm cable and the mc4 from Odimbannamdi and crimp urself. Doubt u wud see a readymade one online |
| Re: Solar Energy, A Complement To FTA by capnies: 2:01pm On Feb 03 |
Drgreatone:ODIMBANNAMDI THIS NAME IS STRANGE HERE WHERE'S HIS |
| Re: Solar Energy, A Complement To FTA by lekanherr: 5:43pm On Feb 03 |
capnies:He is also known as Iinnov8. Mind you it is iinnov8 |
| Re: Solar Energy, A Complement To FTA by fuckboys: 5:53pm On Feb 03 |
Abeg I fit use this connector join 2 solar cables?, I no get tools to crimp mc4 connectors abeg.
|
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 6:31pm On Feb 03 |
fuckboys:No o. Remove the metal part of the mc4 and crimp with a plier at least it is far better than the above. Soldering it is the BEST. AND PLEASE DON'T USE THE ABOVE it is strictly for ac connection. It will melt. |
| Re: Solar Energy, A Complement To FTA by fuckboys: 7:06pm On Feb 03 |
dollarnaira:I don connect am self come down from the roof. Which kind wahala be this now. |
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 7:15pm On Feb 03 |
fuckboys:Why u no wait for response before you climb up? Pele |
| Re: Solar Energy, A Complement To FTA by Fakeisfake: 7:41pm On Feb 03 |
fuckboys:Even if you Wan use this type, use the industrial one but the problem be say after some months, u must go back and re tighten the screws. So better to use the right connectors or solder like say u dey manufacture lead. Waste lead on the joints as already adviced that's if you fit draw power to the roof to power the soldering iron... Lol. Original lead though! |
| Re: Solar Energy, A Complement To FTA by fuckboys: 7:44pm On Feb 03 |
dollarnaira:I will leave it for a week and see how it goes. My landlord don tire for my matter. everyday I dey climb roof. Ai said it will work but will corrode over time and that is the only issue I see there, I didn’t tape it just left it exposed like that. If it can handle ac current of 230v, I don’t see reason why it won’t handle dc current of 160+V under 10amps. |
| Re: Solar Energy, A Complement To FTA by fuckboys: 7:46pm On Feb 03 |
Fakeisfake:well I don’t see reason why I need to retighten those screws over time cos there’s absolutely no tension on those wires. They just lay flat on the roof surface. The only thing I’m scared of is corrosion over time. I didn’t tape it or anything, just left it bare like that after attaching the wires |
| Re: Solar Energy, A Complement To FTA by Edrizz(m): 7:56pm On Feb 03 |
fuckboys:For rust to occur, all trio of water, sun n air must be available, I would suggest u tape it all round to prevent rusting of the screws |
| Re: Solar Energy, A Complement To FTA by Fakeisfake: 8:07pm On Feb 03 |
Edrizz:If it's the industrial type, it comes with galvanized or brazz metal cube and screw inside the plastic so rust will be a long time issue. To reduce the rust rate, yes tape it. You should get it same place you got this. But the screw will slack over time dew to heat expansion and reduction from current flow in the cable.
|
| Re: Solar Energy, A Complement To FTA by capnies: 11:43pm On Feb 03 |
Why this massive reduction in prices of cworth batteries. Are they good lifepo4 batteries or deep cycle batteries. Please who has used cworth 12v 100A battery |
| Re: Solar Energy, A Complement To FTA by capnies: 12:37am On Feb 04*. Modified: 7:49am On Feb 04 |
@Valto Why don't you use gotion batteries in you DIY packs |
| Re: Solar Energy, A Complement To FTA by capnies: 12:38am On Feb 04 |
Where can I get good fuses for 24v system atleast 32v to 70v rating |
| Re: Solar Energy, A Complement To FTA by Betnomore: 7:37am On Feb 04 |
I currently use four 300w mono crystalline panels, a 30amps pwm charge controller, a 1.6kva luminous inverter and 2 tubular batteries. Issues I'm facing is that days when we don't have light, I noticed that it does not charge well because most times I use NEPA light to charge the inverter and barely notice that charging from the solar panels itself is not optimal. I was told to change the controller to an mppt charge controller to get better charging speeds. The issue right now is I'm moving to another apartment and won't be able to use NEPA to charge the setup. What is the best upgrade I can give my current setup besides changing the batteries. I'm open to changing the panels and even getting a hybrid inverter. All input will be highly appreciated. I just need my current setup to charge well with solar as I won't be using NEPA to charge the batteries again |
| Re: Solar Energy, A Complement To FTA by favouredbymercy: 8:00am On Feb 04 |
Betnomore:1. What voltage is your system? 2. What is the highest amount are you will to spend on the upgrade for panels and inverter? |
| Re: Solar Energy, A Complement To FTA by Betnomore: 8:04am On Feb 04 |
24v system I'm willing to get bi-facial jinko panels and also hybrid inverter. I can still do like 700k I need a setup that will charge my battery well and also supply light during the day well without consuming much of my battery. Only things connected to my setup are light bulbs, 3 ceiling fans and 2 standing fans, 2 TV, one game console favouredbymercy: |
| Re: Solar Energy, A Complement To FTA by favouredbymercy: 8:11am On Feb 04 |
Betnomore:Contact @ Dam5reey to get the Haisic 24v Hybrid Inverter, then try add small thing so the remaining cash can get you 4 panels (remember to connect all panels in series this time, not the way it was on the pwm). With these you are good to go. Then later ehen the funds are available, you can then upgrade your battery to lithium. |
| Re: Solar Energy, A Complement To FTA by Betnomore: 8:15am On Feb 04 |
The current setup is also connected in series. My issue now is that if I get a mppt charge controller, will it significantly improve charging speeds or I should just change panels and go for hybrid inverter. If using mppt charge controller will significantly improve my charging speeds, I see no reason to change panels and inverter. favouredbymercy: |
| Re: Solar Energy, A Complement To FTA by favouredbymercy: 9:36am On Feb 04 |
Betnomore:You have a PWM and connected your panels in series? . Na you do am yourself or na installer do am? Or you dont know what series and parallel means |
| Re: Solar Energy, A Complement To FTA by Betnomore: 10:15am On Feb 04 |
Na installer do am and he connected it in series. Please check my signature and send me a message on Whatsapp so you can enlightened me better as I can't seem to find your number on your profile. Thanks favouredbymercy: |
| Re: Solar Energy, A Complement To FTA by Drgreatone: 11:24am On Feb 04 |
Solar alone wont be enough to adequately charge ur batery cos of its chemistry. Reason u didnt notice like u said was because u had NEPA. Tubular batteries take longer to charge so the daily 3-4hrs of peak sun might not suffice. MPPT would have to be a high voltage one which is rare and expensive compared to just getting an hybrid. The common blue powmr needs a max VOC of 105v for 24v battery which u may overshoot with ur 4 panels as one doesn't know their VOC Betnomore: |
UPS Back-up, Also A Complement To FTA • FTA Frequency • Cctv Installation A Complement To Fta And Solar Energy • 2 • 3 • 4
Free To Air Satellite Tv General Thread
Viewing this topic: OgogoroFreak(m), capnies, HawkTuahGirl and 6 guest(s)
. Na you do am yourself or na installer do am? Or you dont know what series and parallel means