| Re: Solar Energy, A Complement To FTA by Gshems: 8:08pm On May 07 |
Omo. Na to keep money for one side in case gobe happen Darey00: |
| Re: Solar Energy, A Complement To FTA by Gshems: 8:41pm On May 07 |
@valto does anern 12v inverter has WiFi monitoring |
| Re: Solar Energy, A Complement To FTA by osayuwamwen(m): 9:24pm On May 07 |
the battery is very good sofar no issue, I have never have any case of bms tripping off, I use the battery to pump 1.5hpower submersible pump, I they use the battery cook with my induction cooker morning and evening, my deep freezer and one small table fridge is always On 24hrs bcus my wife uses them to produce ice block she sells and we on 2 small fan till day break, and from voltage calculation I will still be having 50 40 percent left in the morning b4 pv input I set my inverter charge and discharge parameters so I never experience this questions u are asking but below is the battery manual for answer to yr questions senator282:
|
| Re: Solar Energy, A Complement To FTA by hoover420: 9:27pm On May 07 |
Gshems:Yes o! |
| Re: Solar Energy, A Complement To FTA by osayuwamwen(m): 9:31pm On May 07 |
remind me of one famicare inverter I use one time that inverter they on same noise level with my big genDarey00: |
| Re: Solar Energy, A Complement To FTA by mctfopt: 9:54pm On May 07 |
sirneyo2005:It should be close to each other. The red indicates the battery with the lowest voltage. But as it stands, it's not looking good. Charge it full and observe if this continues. Is this a DIY build? I noticed the sense wire resistances are off which indicates wire length of difference sizes or contact torque of different magnitude. If all fails, consider top balancing the batteries, that is put every call in parallel and charge to 3.60 to 3.65V. |
| Re: Solar Energy, A Complement To FTA by senator282: 10:26pm On May 07 |
osayuwamwen:Alright thanks for your response,this information will be very helpful for me making my final decision. |
| Re: Solar Energy, A Complement To FTA by cutefy: 11:08pm On May 07 |
osayuwamwen:This is just perfect. What's the name of the inverter, what's its capacity and lastly what's ur panels' capacity? |
| Re: Solar Energy, A Complement To FTA by osayuwamwen(m): 2:26am On May 08 |
luxsun 4.2kw 24v inverter 7 pieces of 535watt jinko panel cutefy: |
| Re: Solar Energy, A Complement To FTA by adimx(m): 7:00am On May 08 |
osayuwamwen:Do you equally use grid to charge your batteries? |
| Re: Solar Energy, A Complement To FTA by cutefy: 7:58am On May 08 |
osayuwamwen:Ok. That explains better. I thought you're on a 12v system. |
| Re: Solar Energy, A Complement To FTA by osayuwamwen(m): 8:08am On May 08 |
no adimx: |
| Re: Solar Energy, A Complement To FTA by tziz(m): 9:09am On May 08 |
Darey00: It's always funny wen I read this kindda complaint. Is it that y'all keep ur Inverters beside u on ur bed while u sleep? Or mayb just use the tin to do pillow? I no just understand o. Cos even when my Haisic is on bulk charge and fan's blazing, once I enter my sitting room on my fan, I dnt hear it again o; and I installed it in a small corridor just next to my sitting room, no door in between. I guess its either y'all hav very sensitive ears or those Inverters actually use "OX" Industrial Fan for cooling. What occasionally troubles me (especially in the midnite) is the loud beep from the inverter when power is restored or cut. Of which I'll soon switch off one of these days. ![]() |
| Re: Solar Energy, A Complement To FTA by didymario7(m): 9:42am On May 08 |
osayuwamwen:Pls how much is this battery in the market as o today? |
| Re: Solar Energy, A Complement To FTA by Dam5reey(m): 9:42am On May 08 |
Darey00:Bolded is where issue. The inverter is working too hard and the cooling is not enough. Service center is close to non existing Na why we stick to Sako instead |
| Re: Solar Energy, A Complement To FTA by Tdoctor(m): 10:44am On May 08 |
Tdoctor:Please, anyone with info on Aiko solar panels? |
| Re: Solar Energy, A Complement To FTA by sirneyo2005: 11:18am On May 08 |
Thanks for your response it's a DIY battery pack that particular cell drain faster than others codemaster2much: |
| Re: Solar Energy, A Complement To FTA by EMuyi1(m): 11:56am On May 08 |
Thanks @all I've gotten 6mm cables, I intend to add one more 330w pannel in series, I just hope it won't destroy d 40am mppt AyobamiOluwole: |
| Re: Solar Energy, A Complement To FTA by AyobamiOluwole: 12:05pm On May 08 |
EMuyi1:Below was my first attempt to help you, but it seems you got too many info from folks here. Read it word for word and apply it. If you apply it, and there is still an issue, then there is a problem. The problem doesn’t matter with the panels you will buy (cos you’ll eventually need it).
|
| Re: Solar Energy, A Complement To FTA by adimx(m): 12:24pm On May 08 |
osayuwamwen:That's interesting. Which means you're off grid with your setup fully ba? |
| Re: Solar Energy, A Complement To FTA by fuckboys: 1:43pm On May 08 |
Darey00:LMAO ![]() |
| Re: Solar Energy, A Complement To FTA by fuckboys: 3:32pm On May 08 |
Gshems:arnern fan noise is worst than sako |
| Re: Solar Energy, A Complement To FTA by fuckboys: 4:43pm On May 08 |
tziz:chief I can't sleep in a noisy environment. My haisic inverter wanted to make me run mad before I swapped out the fans with real brushless fans. |
| Re: Solar Energy, A Complement To FTA by didymario7(m): 5:34pm On May 08 |
fuckboys:Who did the fan swapping for you? |
| Re: Solar Energy, A Complement To FTA by Compliant(m): 6:18pm On May 08 |
@valto , please what is the highest kwh 24v battery you presently have with communication ports? |
| Re: Solar Energy, A Complement To FTA by fuckboys: 6:19pm On May 08 |
didymario7:I did the operation myself, now I have peace of mind at night.
|
| Re: Solar Energy, A Complement To FTA by ajabani4allah(m): 6:55pm On May 08 |
So, I opened up this Dayo Induction cooker, I discovered that a leg of the temperature sensor under the plate is out of it's socket. I quickly fix it back and boom! it's now working perfectly
|
| Re: Solar Energy, A Complement To FTA by dollarnaira(m): 7:12pm On May 08 |
ajabani4allah:Na person like you I dey like. Open the stuff, it is not rocket science. Some of us will be thinking of returning to manufacturer. Good one bro. Another guy here too boost up his cells with the help of Penuel. Open the stuff ![]() |
| Re: Solar Energy, A Complement To FTA by Deluxe8000(m): 7:37pm On May 08 |
Please how did you get the 1000. Mine is showing 270c. ajabani4allah: |
| Re: Solar Energy, A Complement To FTA by Deluxe8000(m): 7:42pm On May 08 |
Please house is luxsun 4kva 24v inverter a good inverter
|
| Re: Solar Energy, A Complement To FTA by micxwell(m): 8:00pm On May 08 |
Deluxe8000:Try read the previous 3 pages. You'll get the information you need. |