Solar Energy, A Complement To FTA - Satellite TV Technology (2384) - Nairaland
Nairaland Forum › Entertainment › TV/Movies › Satellite TV Technology › Solar Energy, A Complement To FTA (3411898 Views)
1 2 3 ... 2381 2382 2383 2384 2385 2386 2387 ... 2395 Reply (Go Down)
| Re: Solar Energy, A Complement To FTA by prince4pro2: 12:03pm On Jun 07 |
bassdow:. Yah, especially Aba, markets don't open even banks, but road sellers open |
| Re: Solar Energy, A Complement To FTA by prince4pro2: 12:05pm On Jun 07 |
bassdow:Thanks boss |
| Re: Solar Energy, A Complement To FTA by chadbasin: 12:20pm On Jun 07 |
Valentinooo:This is quite amazing! Please what time was "peak sunlight"? |
| Re: Solar Energy, A Complement To FTA by oloet: 1:54pm On Jun 07 |
At what system voltage are generating this? What is the orientation of your panels? Valentinooo: |
| Re: Solar Energy, A Complement To FTA by Valentinooo: 2:10pm On Jun 07 |
chadbasin:My peak period here is between 12:30 - 1:30pm |
| Re: Solar Energy, A Complement To FTA by micxwell(m): 2:19pm On Jun 07 |
Valentinooo:This is good o 👍 |
| Re: Solar Energy, A Complement To FTA by Valentinooo: 2:19pm On Jun 07 |
oloet:At 365v. It's a shop, the roof is nearly flat. |
| Re: Solar Energy, A Complement To FTA by micxwell(m): 2:23pm On Jun 07 |
twinskenny:No installer will take up this job. |
| Re: Solar Energy, A Complement To FTA by Valentinooo: 2:50pm On Jun 07 |
Paschal007:The generation is poor. Though, power generation depends on so many factors. Panels work best on nearly flat surfaces. |
| Re: Solar Energy, A Complement To FTA by Gshems: 3:20pm On Jun 07 |
Great fuckboys: |
| Re: Solar Energy, A Complement To FTA by prince4pro2: 3:21pm On Jun 07*. Modified: 4:56pm On Jun 07 |
I don go mess up ![]() |
| Re: Solar Energy, A Complement To FTA by Ezimuoh: 3:32pm On Jun 07 |
prince4pro2:Your charge controller is supposed to have settings for system voltage, I guess its currently set at 12V, you need to change it to 24v. Share a picture of the cc |
| Re: Solar Energy, A Complement To FTA by AyarmBoye(m): 3:37pm On Jun 07 |
prince4pro2:you need to set the CC to 24v before you connect the battery to it since the battery is 24v…. |
| Re: Solar Energy, A Complement To FTA by fuckboys: 3:51pm On Jun 07 |
Paschal007:this is very poor. |
| Re: Solar Energy, A Complement To FTA by prince4pro2: 4:59pm On Jun 07 |
Ezimuoh:
|
| Re: Solar Energy, A Complement To FTA by prince4pro2: 5:00pm On Jun 07 |
AyarmBoye:On a nom it automatically detects battery voltage |
| Re: Solar Energy, A Complement To FTA by AyarmBoye(m): 5:11pm On Jun 07 |
prince4pro2:yea a good controller should |
| Re: Solar Energy, A Complement To FTA by prince4pro2: 5:18pm On Jun 07 |
AyarmBoye:Is like the communication cable I plug from my battery to it caused everything. Tuesday I go carry am go for repair alongside the sarchet inverter. Na experiment lead me to wahala . Regardless moving man keeps moving |
| Re: Solar Energy, A Complement To FTA by Ezimuoh: 6:36pm On Jun 07 |
AyarmBoye:I once had a grovolt cc that had a setting to automatically detect system voltage or set the voltage manually |
| Re: Solar Energy, A Complement To FTA by Bryanluke: 7:06pm On Jun 07 |
bassdow:ask questions chief.. I cross posted same time i posted here and also on house clearance sales so don't get me wrong. However I needed it for an airtel universal mifi that uses unlimited sim same as router ..and not all mifi works with it but mine work with it |
| Re: Solar Energy, A Complement To FTA by Segun2222: 7:06pm On Jun 07 |
hardeycute:do you still need i/p/t/v free trial |
| Re: Solar Energy, A Complement To FTA by bassdow: 7:55pm On Jun 07 |
Valentinooo:At such voltage, ensure whoEver is handling your project doesn't do anyHow work Ooo. DC is more wicked that AC |
| Re: Solar Energy, A Complement To FTA by bassdow: 7:56pm On Jun 07*. Modified: 8:18pm On Jun 07 |
micxwell:TRUST me there are. People dey. Probably One just getting started or whatEver. Issue is should things go wrong, said client would never mention how much they paid |
| Re: Solar Energy, A Complement To FTA by bassdow: 7:58pm On Jun 07*. Modified: 8:18pm On Jun 07 |
Valentinooo:and cooler environment. unFortunately, lots of roofs are becoming Sloppy Walls nowAdays |
| Re: Solar Energy, A Complement To FTA by bassdow: 8:04pm On Jun 07 |
prince4pro2:Hopefully, my response to you yesterday evening / this morning wasn't brief enough for you to not miss the highlighted area below
|
| Re: Solar Energy, A Complement To FTA by cutefy: 8:07pm On Jun 07 |
prince4pro2:I just saw your post. Sorry this is coming late. There's one thing about stand-alone inverters, they need to be connected directly to the battery terminal. The charge controller should also be connected separately and directly to the battery terminals, (except you're using hybrid inverter where just one wire to the battery serves as both charge input and discharge output). When you do this, the CC will detect the potential difference between the terminals of the battery and prepare for charging. The inverter does not have such potential difference across it's terminals. Now you've learnt your lesson, don't repeat same mistake. |
| Re: Solar Energy, A Complement To FTA by bassdow: 8:07pm On Jun 07 |
bassdow:BUT the charge controller mostly are built to protect themselves to an extent so all should be fine. Just select the appropriate battery voltage and all should be fine. Also and very important (especially for low quality charge controllers), ensure to connect the battery first, before the solar panel(s) Another thing is, you sure issue ain't from the way you tapped from the battery ? Could you try powering OFF the inverter first and see if the charge controller at least works well with the new battery |
| Re: Solar Energy, A Complement To FTA by bassdow: 8:10pm On Jun 07 |
[quote author=prince4pro2 post=139644870][/quote]though haven't used this product for any client BUT it looks like it should autoSelect battery voltage. Are you sure you connected the battery cable to the right terminal and right polarity ? Certain mistakes are easy to make aTimes |
| Re: Solar Energy, A Complement To FTA by bassdow: 8:13pm On Jun 07 |
prince4pro2:what communication cable ? Doubt that charge controller is meant to communicate anyThing. Na to just connect battery and solar panels. try connecting again, they show us image of the error you getting and terminals. |
| Re: Solar Energy, A Complement To FTA by solasola(m): 8:42pm On Jun 07 |
60k can't do my feeding sef twinskenny: |
| Re: Solar Energy, A Complement To FTA by Feleezy(m): 9:24pm On Jun 07 |
a bungalow is sandwished between two 4 storey buildings at the side. The roof barely sees two hour sunlight. how do one work around that. |
| Re: Solar Energy, A Complement To FTA by prince4pro2: 10:00pm On Jun 07 |
bassdow:Exactly that cc isn't meant to communicate. |
UPS Back-up, Also A Complement To FTA • FTA Frequency • Cctv Installation A Complement To Fta And Solar Energy • 2 • 3 • 4
Free To Air Satellite Tv General Thread
Viewing this topic: dollarnaira(m), Prince3030
I don go mess up
. Regardless moving man keeps moving