Re: Solar Energy, A Complement To FTA by Elizkid: 6:43pm On Sep 08
bassdow:
yes but you didn't state location or if it's 24v system or not
12v

Lagos
Re: Solar Energy, A Complement To FTA by bassdow: 7:33pm On Sep 08
Elizkid:
12v

Lagos
Yes
There's a 1.2kva 12v available less than 100k.

There's also 12v 2.5 kva pure sineWave Inverter ( not Hybrid ) for 180k
Re: Solar Energy, A Complement To FTA by chadbasin: 10:13pm On Sep 08
Beframia:
Good evening house,
It's been almost two weeks now that I noticed that my battery charges and stops at the 3rd bar, not getting to the 4th. My inverter type is Genus Hi-Flo 4.2kVA 24V paired with a 3kwh luxwatt lithium battery, and three 685w bifacial Runergy panels.
Has anyone had a similar experience and how was it resolved?
Please how good are these Runergy panels, someone has been trying to convince me to buy them.
Anyone?
Re: Solar Energy, A Complement To FTA by Elizkid: 8:07am On Sep 09
bassdow:
Yes
There's a 1.2kva 12v available less than 100k.

There's also 12v 2.5 kva pure sineWave Inverter ( not Hybrid ) for 180k
Is the 1.2kva hybrid?


I need it
Re: Solar Energy, A Complement To FTA by bassdow: 8:48am On Sep 09
Elizkid:
Is the 1.2kva hybrid?


I need it
there is a 12v 1kva Hybrid inverter that can accept up to 2pcs of 620w solar panels and it's transformer based 15ok
Re: Solar Energy, A Complement To FTA by Elizkid: 9:04am On Sep 09
bassdow:
Yes
There's a 1.2kva 12v available less than 100k.

There's also 12v 2.5 kva pure sineWave Inverter ( not Hybrid ) for 180k
You said it’s available for less than 100k
Re: Solar Energy, A Complement To FTA by bassdow: 9:38am On Sep 09
Elizkid:
You said it’s available for less than 100k
Those 2 inverters mentioned earlier are not hybrid inverters.

You specifically asked for a hybrid one and I responded with a totally different one which is 1kva 12v hybrid transformer based inverter.
Re: Solar Energy, A Complement To FTA by rapheal5(m): 11:34am On Sep 09
bassdow:
Any brand of Solar panel work for any inverter / setUp. What matters is the Solar panel being of good quality.
Thanks
Re: Solar Energy, A Complement To FTA by Elizkid: 12:28pm On Sep 09
bassdow:
Those 2 inverters mentioned earlier are not hybrid inverters.

You specifically asked for a hybrid one and I responded with a totally different one which is 1kva 12v hybrid transformer based inverter.
Okay
Re: Solar Energy, A Complement To FTA by Blaqq2: 1:05pm On Sep 09
This is the sticker at the side


bassdow:
is there no sticker on body of this inverter ?

Una sabi buy funny things. There's advantage in not being the only one writing carryOver exam.

Also don't you have an engineer who could help you. No be everything we fit do from here.
Error 9 could mean different things so we just can't be specific blindly

Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 1:56pm On Sep 09
bassdow:
Service centers in Nigeria are mostly branded looking engineer's workShop. Except it's the more premium brands, you must pay by default and dem go still do shakara for you; unlike the Sadiq down the street.
Sadiq don suffer grin grin grin.
Sadiq go soon adopt their pattern.
Re: Solar Energy, A Complement To FTA by bassdow: 8:03pm On Sep 09
Blaqq2:
This is the sticker at the side
Are you offGrid or you use it alongside NEPA / Generator ?

You should confirm your batteries are healthy enough and not badly low.

You equally might have to confirm your solar panels are giving expected voltage and not exceeding it's max PV VOC

Equally confirm battery settings / configurations are in order.

At end of the day, few times I experienced such error with clients inverters, na faulty system hence if not any of the above. Carry go give repairer.

Me dey install tranformerLess inverters for clients, me dey use transformer based inverter personally.

Recently, someone from this thread reachout that his 5kva inverter has blown almost everyhting in the house and that especially all the light bulbs don blow finish and 1 TV don burn join and freezer dey sing as e dey work and plenty phone chargers don burn finish.

Paid him a visit and after looking around, found out 1 of the 4pcs of tubular batteries was bad. You could imagine. Rather than the thing to go off, e begin do high Voltage.

In light of that sef, would suggest we start preaching using Voltage protectors (not stablizer) by default so that anytime these transformerLess inverters wan craze, at least dem go leave appliances alone.
Re: Solar Energy, A Complement To FTA by mctfopt: 10:47pm On Sep 09
Beframia:
Good evening house,
It's been almost two weeks now that I noticed that my battery charges and stops at the 3rd bar, not getting to the 4th. My inverter type is Genus Hi-Flo 4.2kVA 24V paired with a 3kwh luxwatt lithium battery, and three 685w bifacial Runergy panels.
Has anyone had a similar experience and how was it resolved?
Was it getting to the 4th bar before this? Or was it forever on this 3rd bar.
Re: Solar Energy, A Complement To FTA by Beframia: 7:22pm On Sep 10
So far so good.

chadbasin:
Please how good are these Runergy panels, someone has been trying to convince me to buy them.
Anyone?
Re: Solar Energy, A Complement To FTA by Beframia: 7:37pm On Sep 10
This fixed the problem. I had already configured the battery type to FeL. All I did was just to change the bulk charge voltage from 28 to 28.4v, floating charge voltage from 27 to 28v, discharge cut off from 22 to 22.4v (as specified in the battery's manual), and restarted the setup. The 4th bar was not only restored but fully charged before 12pm.
Thanks.

bassdow:
To accurately debug this ya matter, one needs be physically present BUT we could try.

Check to ensure the battery settings are properly configured. That's certainly where the issue is coming from. If the current config has voltage less than the battery's full charge, then the inverter certainly would stop charging the moment it gets there thinking it's full.

Also be sure this issue isn't a One time thing.

Ensure batteryType is Lithium or Li

or if using custom settings (mostly called USER), then set things manually

Bulk / absorptionVoltage: 28.4v

Float chargeVoltage: 26.8v to 27.0v

Low DC cut off voltage: 23.5v
Re: Solar Energy, A Complement To FTA by Beframia: 7:53pm On Sep 10
It was getting to the 4th bar before now....but this has been fixed by changing some of the battery settings on the inverter.

mctfopt:
Was it getting to the 4th bar before this? Or was it forever on this 3rd bar.
Re: Solar Energy, A Complement To FTA by chadbasin: 8:22pm On Sep 10
Beframia:
So far so good.
Can it be compared with Longi, Jinko?
Re: Solar Energy, A Complement To FTA by bassdow: 12:46am On Sep 11
Beframia:
This fixed the problem. I had already configured the battery type to FeL. All I did was just to change the bulk charge voltage from 28 to 28.4v, floating charge voltage from 27 to 28v, discharge cut off from 22 to 22.4v (as specified in the battery's manual), and restarted the setup. The 4th bar was not only restored but fully charged before 12pm.
Thanks.
Glad to be of help
Re: Solar Energy, A Complement To FTA by bassdow: 12:47am On Sep 11
Beframia:
So far so good.
This your kinda response eh
Re: Solar Energy, A Complement To FTA by Beframia: 4:37am On Sep 11
I've never used any of those but the dealer confirmed to me that it's a good brand. I settled for it after a mere physical assessment of the panels, they looked sturdy - although not the standard test for quality but I couldn't wait for when next he would have jinko in stock.

chadbasin:
Can it be compared with Longi, Jinko?
Re: Solar Energy, A Complement To FTA by bassdow: 7:29am On Sep 11
Beframia:
I've never used any of those but the dealer confirmed to me that it's a good brand. I settled for it after a mere physical assessment of the panels, they looked sturdy - although not the standard test for quality but I couldn't wait for when next he would have jinko in stock.
That brand is a good brand. Jinko and Longi ain't the only tier 1 brands. na some of us in here paint them that way. That said, would still go with either jingKo or Longi if the 3 are available and I have to choose
Re: Solar Energy, A Complement To FTA by bkuranga(m): 12:46am On Sep 12
codemaster2much:
I need 1 to 1.5 KVA pure sine wave 12v inverter for a project, please anyone that has can mention me
thanks
New?
Re: Solar Energy, A Complement To FTA by bkuranga(m): 12:48am On Sep 12
chadbasin:
Please how good are these Runergy panels, someone has been trying to convince me to buy them.
Anyone?
It's good, I do buy from Bread Trenergy.
The performance has been great.

Let's see if someone here don use it before too.
Re: Solar Energy, A Complement To FTA by seunlayi(m): 5:51am On Sep 12
Anybody has this sryne Bluetooth dongle. I need it

Re: Solar Energy, A Complement To FTA by codemaster2much: 11:40am On Sep 12
Used
bkuranga:
New?
Re: Solar Energy, A Complement To FTA by EndiaSami: 5:55pm On Sep 12
Beframia:
So far so good.
Greetings

Please what's the price like. Or dealer contact will be appreciated

Thank you
Re: Solar Energy, A Complement To FTA by bkuranga(m): 9:25am On Sep 13
codemaster2much:
Used
I no get.
Re: Solar Energy, A Complement To FTA by Beframia: 12:42pm On Sep 13
135k for 685w. Bought in Kaduna.

EndiaSami:
Greetings

Please what's the price like. Or dealer contact will be appreciated

Thank you
Re: Solar Energy, A Complement To FTA by codemaster2much: 1:09pm On Sep 13
Awesome