Re: Solar Energy, A Complement To FTA by pranil(m): 4:34pm On Aug 05, 2016 |
Barezzi: The setup looks enviable. Few thoughts 1. The battery is too small for 4.6 KVA load unless that is your peak load for bedroom /lights - 400 AH is hardly 10 KWH at 50 % DOD at 3 KW it is not even 3 hours of runtime in the night . I have exat seame battery size and I can run 800 watts for one whole night ( which includes 300-500 Watt of bedroom AC) 2. You might want to consider running the inverter in hybrid solar mode during daytime to maximize that 6 KWp Solar panels solar production . In that case I suggest to use changeover along with DOD cut off to keep non essential loads connected to grid if available on days when solar production is not enough otheriwse one angr better half 3. You might consider reducing the solar panel size and investing that amount in energy efficiency ( long term effects will be similar) specially as NEPA bill also comes down. Solar prices will always drop for next few years and you can always add more 1.5 KW diakin or LG AC is around 200,000 NGN but can run on as low as 300-600 WATT. LED bulbs ( i found the Yellights and Philips both reliable )- The yeelights are specially good at less than 20 USD in addition allow dimming and color change from you rsmartphone - http://www.gearbest.com/smart-lighting/pp_361555.html
|
Re: Solar Energy, A Complement To FTA by Barezzi(m): 5:57pm On Aug 05, 2016 |
pranil:To clarify, my house will be divided into 4: Panel #1 will carry ALL the light points in the house and circuitry in the Master bedroom. (~400watts @ night with aircon , 100watts without) Panel #2 will carry the kitchen, wholehouse fans, and Main lounge (~400watts @ night) This panel will drop off once the battery SOC gets to 70% due to grid failure or cloudy days. Both panels above will not exceed 4.6kva. Panel #3 will carry 13A sockets in the rest of the house and 15A sockets in the laundry room/water pump. This panel will get bi-directional feed from the inverter during the day. Panel #4 will carry the remaining 15A loads in the house, and will be supplied directly from PHCN. I plan to concatenate panels 1 to 3 in a single 3-phase panel, while panel 4 will be stand alone. I also plan to upgrade me banks to at least 500Ah. My goal is to keep nighttime backup load demand to 500w. I've got me sights on LG inverter aircon pranil: See comments above pranil: I love automation and control, and i'm looking at integrating the above using zwave via homeseer hs3. Keep it coming bro... 1 Like |
Re: Solar Energy, A Complement To FTA by abunafiu(m): 10:22pm On Aug 05, 2016 |
interested in home automation too. any practical experience to learn from here?. Its been a while since I discussed my personal home set up. I recently hit 3kw pv strength. my 2 yrs old trojans still firing like new. I have switched charge controllers from morning star to FM80 and now midnite classic. I now live off grid and hardly drain my bank below 49.5v(with load) by 6.30am when I wake up. I now switxh off my 4kw mustpower(1.5 years old) inverter off when leaving home for work. once I return home ,I go tru d logged data. my batts reaches absorption usually by 1pm. 3 Likes |
Re: Solar Energy, A Complement To FTA by Barezzi(m): 12:13am On Aug 06, 2016 |
abunafiu:Going off grid sounds intriguing, but alas! it's not for the faint of heart |
Re: Solar Energy, A Complement To FTA by pranil(m): 12:30am On Aug 07, 2016 |
abunafiu: I Have personally tried following air conditioner controllers for automation and love the ambilight followed by broadlink followed by Tado - too lazy to put links but google it they are easily found. On the lights I primary use philips hue with logitech harmony and amazon alexa works wonderfull. Personally I found zwave too much headache. My samsung smartthings is far from smart and constantly looses connectivity with my projector screen controller and it's own socket too many variables in Zwave and not consistent echo system I found the broadlink platform quite good specially their power socket which keeps a history of the power use and current use for any appliance. Very Good to monitor fridge and AC http://www.aliexpress.com/item/Broadlink-SP2-EU-Smart-Home-Wireless-Remote-Control-Electrical-Smart-Plugs-Sockets-By-app-control-switch/32655943437.html I also use the battery monitor to check on battery from bedroom - found good to be 40-60 metrs in open adn 10-20 meters through one wall http://www.aliexpress.com/item/NEW-MHF-120S-Wireless-DC-Voltmeter-Ammeter-Power-Meter-0-120V-100A-Shunt-MHF120100S/32611336909.html 2 Likes |
Re: Solar Energy, A Complement To FTA by samnaija: 12:22am On Aug 08, 2016 |
guys i need your advice. i want to attach an external smart charger to my bank 48v 200ah. what my supplier brought was a rectifer. he claims telcoms use it for their batteries. (48v50amps). is this a smart charger . i dont want something to damage my bank for nothing. |
Re: Solar Energy, A Complement To FTA by pranil(m): 10:12am On Aug 08, 2016 |
samnaija: 200 Ah requires max 20 to 25 Amps C10 rate batteries. Anything more and you will damage the battries unless the charger can adjust current and monitor temperature . If you are willing to order from Aliexpress I can send you link for a very good charger . or altrenatively look on this website and find a way to order http://www.meanwell.com/product/inverter/inverter01.html I found it very difficult to locate a good charger at that capacities as normally it is integrated in inverters 2 Likes |
Re: Solar Energy, A Complement To FTA by Braaad: 11:40am On Aug 08, 2016 |
Please house, where can I get this toroidal transformer? anbody with information should contact me on 08138168936(whatsapp only) ASAP. I would appreciate higher capacities too up to 10kva. thanks
|
Re: Solar Energy, A Complement To FTA by bigrovar(m): 1:20pm On Aug 08, 2016 |
pranil:am interested in this product, can it be used to set timer.. like auto turn off a device after a set time or threshold (say after consuming 500wh)? |
Re: Solar Energy, A Complement To FTA by Im2Busy2Bother: 3:46pm On Aug 08, 2016 |
pranil: Interested in the aliexpress link. Thanks |
Re: Solar Energy, A Complement To FTA by samnaija: 5:48pm On Aug 08, 2016 |
pranil:thnks will look it up. but i still dont know about the rectifer is it a smart charger. |
Re: Solar Energy, A Complement To FTA by DUNKA(m): 5:24pm On Aug 09, 2016 |
Gennextech:good day please what is the current price of these panels? |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 9:10am On Aug 10, 2016 |
bigrovar:for those interested in the device, it does have timer function but it can not be timed by watt threshold (unless one has access to the SDK and modify some parameters.) |
Re: Solar Energy, A Complement To FTA by abbyguy: 4:03pm On Aug 11, 2016 |
Brand new Fiamm monolite AGM batteries for sale(12v, 160ah). These batteries are very strong and can stand the 200ah brand of Chinese and Indian batteries. limited stock available. (20pcs) Price is 85,000naira. For enquiries call- 07032743485 or whatsapp 07032743485
|
Re: Solar Energy, A Complement To FTA by nisol: 2:18am On Aug 12, 2016 |
Braaad: Check any electronics spares market ( Oshodi/alaba if you are in Lagos). I also learnt that Binatone stabilizers use toroidal transformers. Prag stabilizers also use toroidal transformers. you can stack smaller torids to get 10KVA (any particular project in mind?) |
Re: Solar Energy, A Complement To FTA by Wazari: 6:09am On Aug 12, 2016 |
Hello Everyone, I am one of the silent majority that has been reading but not commenting for a long time. This thread has been very informative and helpful to me. I just acquired some quanta 12V 200Ah AGM batteries and I'm not sure of the correct bulk and float voltages. Quanta manuals and website strongly advice 13.8V bulk and 13.5V float (discouraging even a 1% increase) but all other online resources I have found recommend approx. 14.4V bulk and 13.8 -13.4V float. Personally I think the manufacturers recommendation is on the low side, probably more suited to float usage and would not lead to a fully charged battery under cyclic usage. I have the batteries set at 14.4V and 13.6V but I'm concerned about over charging the batteries. What do you guys think? |
Re: Solar Energy, A Complement To FTA by Obimind1: 8:00am On Aug 12, 2016 |
Trippledots:I think u're correct. Most of us in the middle belt area enjoy good sunshine everyday and my pwm 30amp charge controller is doing quite well. Pix of my set up may be posted later. 1 Like |
Re: Solar Energy, A Complement To FTA by chris81964(m): 11:25am On Aug 12, 2016 |
Trippledots: That you have enjoyed success does not make you right. Revisit number 1 and 3 5 Likes |
Re: Solar Energy, A Complement To FTA by abunafiu(m): 1:35pm On Aug 12, 2016 |
obimind: ure welcome sir. so how has it been. |
Re: Solar Energy, A Complement To FTA by mcci: 2:10pm On Aug 12, 2016 |
Thanks to all contributors on this forum. The solar energy revolution is spreading fast. I'm also enjoying it's immense benefit. |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:17pm On Aug 12, 2016 |
You're being nice. The guy is a super learner chris81964: 2 Likes |
Re: Solar Energy, A Complement To FTA by anidat77(m): 10:25pm On Aug 12, 2016 |
My people,I just received this panel I ordered through konga. It looks really strange without the cell terminals in front of the cells. I don't even want to test it yet. Please can anyone tell me this is not a fake. Nairalanders what do you guys think.
|
Re: Solar Energy, A Complement To FTA by Monlo(m): 10:25am On Aug 13, 2016 |
anidat77: Guess,am seeing such for the first time!I can see the cell terminals on the edge of the panel running parallel to it,and it is even mono.I bliv you could have bought from our sellers here or visit the local market.Eventhough all my solar installation constituent were ordered by me overseas,atleast the panels were bought here in Naija.Incase of next time beware.Over to sellers for more.Enjoying my solar installation for 7months now.One love,green all the way. |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 11:51am On Aug 13, 2016 |
Monlo: #word.. Cheers ! |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:02pm On Aug 13, 2016 |
Must Power Star Light inverters 1kva-12v=80k 1.5kva-12v=95k 3kva(2000w)-12v=100,000 3kva(2000w)-24v=130,000 4kva(3000w)-24v=145,000 5kva(4000w)-24/48=200,000 6kva(5000w)-24/48= 230,000 7.5kva(6000w)-24/48= Hybrid inverters with inbuilt PWM controllers 7.5kva-48v=290,000 5kva-48v=250,000 4kva-24v=220,000 3kva-24v=190,000 Hybrid Inverter with inbuilt MPPT control 12KW-48v=870,000 Luminuos zelio 1.5kva with LCD display .....@65k EP Solar 12/24/36/48v 60a mppt(i tracer) solar charge controller @ 140k EP Solar 12/24v 40a MPPT(a series ep ever) solar charge controller @ 65k Fangpuson MPPT 80a solar charge controller .....@ 180k Trojan 12v 205a USA batteries @ 118k...(limited quantity in stock) Quanta Amaron 12v 200a vrla battery @ 110k MY HOME poly crystalline solar panels ; 150w poly panels........@40k 250w poly panels.......@70k "limited stock" 300w poly panels........@75k "limited stock" FLAMES 130w mono panels ......@ 40k CSUN 200w mono panels ........@57k With 35k , I can offer you the most important pro solar roof mounts including ; 2 qty solar mount rail "4200mm" , 4 qty rack end clamp, 6 qty mid clamp, 6 qty L feet with rubber & special screw.... Same goes to angle positioning solar kits; - Adjustable front leg - Adjustable rear leg - Rail splice kit - Grounding lug *AUTHORISED DEALER PRAGMATIC TECHNOLOGIES* All our prag / cyberpower products comes with reliable warranty *AUTHORIZED DEALER INDIAN INVERTERS / BATTERIES ... GENUS , LUMINUOS , EPSILON PRODUCTS* All our products come with 1 year Warranty *AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS* All our products come with 1 year Warranty For best affordable prices,proforma invoices valid for just 1 week, contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !! |
Re: Solar Energy, A Complement To FTA by Trippledots(m): 1:00pm On Aug 13, 2016 |
chris81964: uhm....are numbers 1 & 3 tourist sites? if u have other view or opinion. say it. |
Re: Solar Energy, A Complement To FTA by anochuks08(m): 2:01pm On Aug 13, 2016 |
Trippledots:Pointing to ur No 3, the difference in Voltage will be converted to current via an Mppt Controller. The more the difference, the greater the harvest, provided Mppt is in play. To No 1, I may be wrong and stand to be corrected, but I think distance matters between the charge controller and battery bank. it is advised to maintain the shortest distance possible from charge controller to your battery bank to improve efficiency. 4 Likes 2 Shares |
Re: Solar Energy, A Complement To FTA by Monlo(m): 5:32pm On Aug 13, 2016 |
anochuks08: True talk,my 40A Epsolar MPPt Solar charge controller is a testimony to this fact.Ever since i started using it,no regrets,enjoyment all the way.I have since abandoned my 30A PMW Solar charge controller.The Modus Operandi of MPPT CC still baffles me till date,seems sometimes to defy the laws of energy conversion,with amazing energy output.Green all the way,One love. 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 6:06pm On Aug 13, 2016 |
Monlo: They are more efficient dear.. Under proper charging algorithm settings , your ep ever 40a works well on flooded battery's cos it has ability to equalize too.. You can also Contact me for optional MT50 remote (black color) @ just 16k for user defined settings .. Thanks
|
Re: Solar Energy, A Complement To FTA by iLoveTheSun(m): 1:20pm On Aug 14, 2016 |
@anidat77 Can you please upload a picture of the name/type plate please?! Your module is made of back contact cells, those are manufactured by Sunpower et al. They have one of the highest efficiency in the market, because there are no frontside bars. There are small holes that lead the front to the backside. I have a solar installation with Sunpower modules as well. Each module (1,65 x 1,05m) is 310 Watts(peak)! The open-current voltage is higher than other solar modules. So, you need to get the right solar charger. sunny regards, |
Re: Solar Energy, A Complement To FTA by iLoveTheSun(m): 1:26pm On Aug 14, 2016 |
Oh, the solar boat and the solar plane Impulse 1 & 2 are made of those high-efficiency back contact cells from Sunpower. (>21%) By the way, the preceding company (the original technology) of Sunpower was a solar cell manufacturer for satellites. The founders started Sunpower and went public on NASDAQ. In the meanwhile the French Oil company TOTAL took a big share of Sunpower. Because Sunpower/Total is active as Independent Energy Provider, building their own solar parks, it is hard to get their solar modules. BenQ Taiwan has signed a contract to build solar modules with Sunpower cells. Those are the most expensive ones. - like a Mercedes. |
(1) (2) (3) ... (156) (157) (158) (159) (160) (161) (162) ... (1752) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: fyinka47(m), EduTechTainMent, Edrizz(m) and 3 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 80 |