Decking Design, Please Comment On Possible Solution by csiworksnig(f): 8:14am On Aug 06, 2016
Hi nairalanders, I saw this decking design somewhere in Lagos.. I think the is not right, there was no structural design for the decking though.. The decking is 12m x 12m and ideas told they use 2tons of 16mm, 3tons of 12mmm and half ton of 10mm for that size of decking. Is that not too much for this decking design i don't understand.. I can't see any load bearing beams.. My honourable engs,arcs builders and house owners in the forum, Please add your comments to this post

Re: Decking Design, Please Comment On Possible Solution by VictorRomanov: 2:13pm On Nov 22, 2016
I can see steel members for beams. I can't tell the span of each slab nor the length of the beam from the picture. However from the picture i think they re in order. My only concern are the stirrup/links on the beams, they look too spaced apart. If is it not more than 300mm c/c, then they re in order.

16mm for the beams. 12mm for the main rebars for the slab, while 10 for distribution bars for the slab.

BTW I am a structural engineer.
Re: Decking Design, Please Comment On Possible Solution by csiworksnig(f): 6:31pm On Nov 22, 2016
VictorRomanov:
I can see steel members for beams. I can't tell the span of each slab nor the length of the beam from the picture. However from the picture i think they re in order. My only concern are the stirrup/links on the beams, they look too spaced apart. If is it not more than 300mm c/c, then they re in order.

16mm for the beams. 12mm for the main rebars for the slab, while 10 for distribution bars for the slab.

BTW I am a structural engineer.

Thanks sir..

Problem solved
Re: Decking Design, Please Comment On Possible Solution by VictorRomanov: 6:35pm On Nov 22, 2016
csiworksnig:


Thanks sir..

Problem solved

U re welcome.

(1) (Reply)

What Does Your Dream House Look Like? / Sold out. / *requirements For Layout Approval In Lagos State

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 9
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.