Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / NewStats: 3,194,823 members, 7,956,110 topics. Date: Monday, 23 September 2024 at 02:29 AM |
Nairaland Forum / Entertainment / TV/Movies / Satellite TV Technology / Solar Energy, A Complement To FTA (2296666 Views)
UPS Back-up, Also A Complement To FTA / FTA Frequency / Cctv Installation A Complement To Fta And Solar Energy (2) (3) (4)
(1) (2) (3) ... (262) (263) (264) (265) (266) (267) (268) ... (1809) (Reply) (Go Down)
Re: Solar Energy, A Complement To FTA by pranil(m): 2:06pm On Jun 20, 2017 |
Reprobate: Can you correct B above ( 1 x12 V ) cannot be connected to 24 V inverter . In general any Lead Acid battery ( wet , AGM, GEl) likes to be used on C10 or C5 rate based on design . Any higher current drawn above C10 will result in reducing teh overall AH ( energy delivery) of the battery . So a 220 Ah battery will be able to deliver 220 AH ( 220*12V-2640 watt) if the load is 22 Amps ( 12 V x 22 amps- 264 Watts) for 10 Hours Same battery at Higher load will likely drop to 170 AH Also Keep in Mind the battery should be used only upto 50 % DOD in Home solar applications which means a 12 V 220Ah battery system should be considered In design to support a load of 264 watts only for 5 hours 4 Likes |
Re: Solar Energy, A Complement To FTA by pranil(m): 2:09pm On Jun 20, 2017 |
Thats how a battery should be sold. I am happy to buy from Smartcell everytime as he gets the technical details right and deliveries are prompt kiekie1: 5 Likes |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:00pm On Jun 20, 2017 |
kiekie1: So technically it better to discharge 50% than 30% of battery capacity @30% I will only get 165,000AH from my battery.. whereas @50% I will get 175,000AH. Abeg what's the logic here? |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:32pm On Jun 20, 2017 |
Dam5reey:No! Technically it's better @30% you get longer battery life than @50% 1 Like |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 7:56pm On Jun 20, 2017 |
Oshomo12: What's is the logic..?I get more power discharging to 50% based on life cycle.. that my point.. |
Re: Solar Energy, A Complement To FTA by Ferdiwar: 8:39pm On Jun 20, 2017 |
Dam5reey: The logic is that @ 30% you can charge and discharge it 2750 times while @ 50% you can charge and discharge it 1750 times. That means that while discharging it to 30% the battery lasts longer than when you discharge it to 50%. 1 Like |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:53pm On Jun 20, 2017 |
Ferdiwar: Thank you. More power less life span, less power taken out of the batteries more life span. Hope this is logical? |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 11:16pm On Jun 20, 2017 |
What he meant is overall at 50%, you draw out more returns on investment that at 30%. He is a very good economist however sometimes availability outweighs cost! For instance d 30% discharge plan gives more longevity before replenishment as opposed to more 'harvest' from d system. Oshomo12: 3 Likes |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:55pm On Jun 20, 2017 |
DMerciful: All this solar wahala tire me, can't we just get a perfect battery? Batteries are the most expensive part of the system. I need a battery @90% DoD and 15000 cycles! 3 Likes |
Re: Solar Energy, A Complement To FTA by eddyline(m): 2:24am On Jun 21, 2017 |
Oshomo12:can you afford such batteries? cos they are available. 1 Like |
Re: Solar Energy, A Complement To FTA by bigbrovar: 5:10am On Jun 21, 2017 |
pranil: Once again my reply to your post was eaten up my the stone age clobber Nairaland calls antispam. I got a ban for my effort. Nairaland has to be the only platform where contributors content producers get banned for posting educational stuff that drives more traffic to the site. It is a classic case of the disease that creeps in when you become a monopoly.... anyway I digress. My response has been reposted to my blog below in my signature |
Re: Solar Energy, A Complement To FTA by Saipro(m): 6:57am On Jun 21, 2017 |
pranil: I'll admit he does his homework quite well. When in doubt, he'll call people with real life application and experience to hear their views and inferences. He's good at what he does. And that's how things should be. 2 Likes |
Re: Solar Energy, A Complement To FTA by Saipro(m): 7:04am On Jun 21, 2017 |
Oshomo12: That's why RE is no joke. Takes lots of planning and serious consideration. Money doesn't always come easy but time is about the most expensive currency we humans deal in. You have to do a delicate balancing act between your needs and desires. My own recommendation: if you want more time out of your batteries, size them appropriately or get the right chemistry type. |
Re: Solar Energy, A Complement To FTA by Saipro(m): 7:09am On Jun 21, 2017 |
bigbrovar: I learnt a few years ago to always copy my replies before posting them. Nasty surprises occur more frequently than one would expect (my first post today required 4 attempts to get it through). And it seems the site has a grudge with the Glo network. 1 Like |
Re: Solar Energy, A Complement To FTA by tivta(m): 8:12am On Jun 21, 2017 |
Oshomo12:Simpliphi has a dod of 80% with over 10000 cycles but cost about $3800 per 64amps at 48volts |
Re: Solar Energy, A Complement To FTA by Reprobate: 11:50am On Jun 21, 2017 |
pranil: sorry for the mix up, I meant a 12v inverter setup for option B |
Re: Solar Energy, A Complement To FTA by BasedOnB: 1:34pm On Jun 21, 2017 |
Hello everyone, i need some quick advice here please. I have a 800 VA sukam inverter, a 250 W panel, and a 30 amps PWM controller. My current 150 AH battery is long due for replacement, so i am thinking of replacing it with a new 200 AH. My concern is that the panel may take too long to charge the battery full, even though i don't intend to discharge it to more than 50%. Am i just better off with a smaller battery, say a 150 AH or 100 AH? I also need recommendations on reliable battery brands to buy (preferably from experience), i kinda believe the so called 'telecom' batteries are solid, even if they are more expensive. |
Re: Solar Energy, A Complement To FTA by pranil(m): 2:25pm On Jun 21, 2017 |
Reprobate: Explained nicely here - http://bobby.com.ng/2017/06/21/battery-discharging-less-can-be-more/ In general 24 V system will be more efficient and run longer |
Re: Solar Energy, A Complement To FTA by chris81964(m): 3:29pm On Jun 21, 2017 |
For folks that love monitoring. Here is a brief video with the Combox. You can do everything you can do with the SCP and more from your android tablet or laptop. https://www.youtube.com/watch?v=UXzUowIi91Y 1 Like |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 4:44pm On Jun 21, 2017 |
BasedOnB: you didn't state your load... concerning battery brand, you can go for Ritar/sukam/safepower |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:04pm On Jun 21, 2017 |
tivta: I beg no talk this battery! Na to sell my landed properties before I can afford 200ah. |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:13pm On Jun 21, 2017 |
Saipro:I totally agree with you. |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 9:33pm On Jun 21, 2017 |
BasedOnB: From experience panel array only produce 3 to 4 times it's capacity.. So your 250W will provide about 800Wh.. thats about 60AH of charge.. if you upgrade by 50AH how do you charge it? If your 150AH is serving well with the panel.. then stick with it.. since 30A PWM cannot accept a perfect additional panel.. |
Re: Solar Energy, A Complement To FTA by BasedOnB: 10:35pm On Jun 21, 2017 |
mcTrinity: Thanks. Load is about 120 W max, most times it's just about 80 W. |
Re: Solar Energy, A Complement To FTA by BasedOnB: 10:41pm On Jun 21, 2017 |
Dam5reey: The 150 AH battery is virtually dead, i have to change it. So the 30 amps controller can't charge a 200 AH battery? Thanks for the input. |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 11:10pm On Jun 21, 2017 |
BasedOnB: It can, simply add another panel.. I mean you should buy another 150AH battery if your panel charges it effectively.. |
Re: Solar Energy, A Complement To FTA by BasedOnB: 11:19pm On Jun 21, 2017 |
Dam5reey: I get your point now, can't buy an extra panel at the moment. Thanks once again. |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 1:15am On Jun 22, 2017 |
pranil: Am humbled Sir, I appreciate your patronage so far .. We are always at your service |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 1:19am On Jun 22, 2017 |
Dam5reey: You are getting it all wrong bro.. Its simplified & self explicit if you look at the number of cycles at different DOD % ! Cheers |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 1:21am On Jun 22, 2017 |
Saipro: Thanks & God bless ! |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 1:26am On Jun 22, 2017 |
LOADING.... Fairly new 12v 200a batteries , limited quantity coming soon ! watch this space .................... |
(1) (2) (3) ... (262) (263) (264) (265) (266) (267) (268) ... (1809) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 54 |