Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 12:53pm On Jul 01 |
mosak: Thank you everyone, I thought about fouani also but I thought I can get another genuine distributor with lower price compared to fouani. Which location are you trying to buy the panel? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 10:53am On Jun 16 |
prince4pro2: Powmr pwm 80a and sms mppt 60a, which of them do u need Still available? I'm looking to buy the SMS. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 7:13am On Jun 04 |
Bryanluke: Do we still have any honest and trustworthy solar panel seller in Alaba or Oshodi here... who will give any wattage panel and it'll be the exact wattage.
Some sellers are not trust worthy at all Original panels available in Ilorin. |
Technology Market › Re: House Clearance Sales.. Come In Here!!!! by bkuranga(m): 12:38pm On Jun 03 |
fuckboys: Lenovo Thinkpad T430 I5 3rd gen Windows 11pro 24H2 8gb DDR3 RaM upgradable 128gb SATA SSD Ugradable Fingerprint Keyboard light Bluetooth WiFi Very clean with single vertical line on the screen, not noticeable. 3CELL battery, already weak last about 1hr30mins.
Giveaway price of 100k pere, na dash be this. Selling cos I got a mad X1 Carbon as a gift. How do I contact you? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 8:12am On May 22 |
fuckboys: nawa o ,everybody tom dick and harry sharing opinions on the Internet.
I was comfortably ironing cloths with my Philips 1000w iron on a 1.5kva 12v bread inverter.
So people with A/c will have to get a 20kva inverter then. As I see that comment of not using so and so on a 6KVA inverter, I nearly fainted. Like, do we now need 12KVA abi something bigger to use an iron? Waiting we go come need to use hot plate? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 8:56am On May 09 |
osayuwamwen: majority of inverter for marker are all almost same component just different branding and if u look at the price level they are all almost around same price too except they wan cheat u, and top tier inverter are very expensive, look am this way techo,itel,infinix vs Samsung, iPhone I know. But we shouldn't be telling people asking questions from a place of doubt to shut up and stop disturbing us here. I asked when I didn't have much idea, and even now I still ask when I need a second opinion or have no idea. The only stupid question is the one not asked. Beside, between these inverters, preference still they. I have used different ones and they have their strong point. Like Bread, I notice most of their inverters read voltage wrongly and need tweaking in the settings if installer no wan enter wahala. Luxsun, voltage reading is excellent but the noise is a bit much. And so on... If someone is asking question, it means they have doubt or no idea and we can either answer them or waka pass. Instead of telling them to stop disturbing. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 8:27am On May 09 |
fuckboys: Oga choose your best devil abeg, make una no Dey ask all these true questions for here again.
Haisic, Cworth sako luxsun anern are all the same grade of inverter. Not the top tier.
Choose any of them and rest without disturbing us here abeg. This is just wrong, bro... When you had your doubts, didn't you ask here too? Now telling someone to stop disturbing or ask questions. Uhnnnn? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 8:19am On May 09 |
osayuwamwen:
remind me of one famicare inverter I use one time that inverter they on same noise level with my big gen Tell me this is a joke abeg?  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 8:08am On May 09 |
codemaster2much: Hi everyone,I need help reviving a HenryLFE 12V 150Ah battery drained to 10.24V. The BMS is locked and the Bluetooth signal has disappeared (it won't show up on any phone/app).What we've tried:14.6V 20A LiFePO4 Charger: Won’t start; doesn't "see" the battery.Parallel Jump: Tried jumping with another battery, but the BMS won't wake up or allow the charger to take over. Help If your charger controller/hybrid inverter have lithium profile, set to lithium should be able to wake it. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 9:46am On May 06 |
osayuwamwen: I they wonder how battery take they deplete to 0% and battery won't wake, is the internal bms only for balancing ? all this cheap substandard battery, una they laugh me here when I bought humsienk 12v 314ah lifep04 battery, before I install my hybrid inverter then I was using the battery on sachet inverter were i drain the battery to as low as 10v and the bms nor they short down BMS allowing you to go that low isn't a sign of a QUALITY BMS though. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 3:55pm On May 05 |
Dabss: Thank you. Please what size cable do I need from the inverter to the battery? AI is telling me that I need a 20mm cable for a 4000w inverter. I mostly try to use 25MM as my minimum for such. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 9:40am On May 04 |
Dabss: no error code. That's weird. I'm suspecting over temperature, but if it's that. There should be a fault code. But if it's just going off, it might be a lose connection from battery to inverter. From my experience, this has happened before. Check that the cables are tightly connected. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 10:17pm On May 03 |
OgogoroFreak: qasa has infrared cooker too? I mean this ceramic hot plate.
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 4:20pm On May 03 |
justasitis: The magnetic metal underneath the induction pot is preventing the pot’s base to heat up on time hence the error 4 showing on the cooker. But the Error will disappear as soon as you increase the heat / wattage. So, to avoid this error, just use regular pots on the infrared cooker. The error is indicating an unusual slow heating. Oh, I see. Thank you. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 3:12pm On May 03 |
Dabss: Guys I changed my inverter to Lvtopsun 4000w inverter yesterday and the inverter has been randomly turning itself off and on. What could be the likely cause? Battery voltage is not low. Inverter not giving any error/fault code? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 3:10pm On May 03 |
AyobamiOluwole: Be careful of the advice you are getting and don’t fry your controller.
There was a reason it was configured 4S2P in the first place. Connecting all in series means you’ve tripled the VOC of your panel. Therefore, you need to confirm if this tallies with what your controller can take, else, you will burn your controller. That's another point. He was asking if it's safe with the cable though. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 3:06pm On May 03 |
justasitis: I have never experienced such ever since I have been using the Fred infrared cooker for over 8 months now. It has been serving my family of five well and the cooking is great just like charcoal stove cooking but much more faster and energy efficient. However, the error could be as a result of the magnetic pot you are using on it. The infrared cooker does not require a magnetic pot to work unlike induction cooker. You should confirm this by using any regular pot on it and observe if it shows the error. You can even start by touching the Power On, then Touch BBQ - 1200W for instance, and then reduce or increase the wattage. I have just bought extra two for my clients . It's been very effective when working for me too. I was using Qasa before this, and this one is far better. Just this weird error. I will try another type of cookware. In fact, I will also buy more of this cooker in case my clients need one. Thank you. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 7:53am On May 03 |
justasitis: Fred Infrared Cooker, it costs between 40-50k depending on where you’re buying from and comes with a steel for grilling or barbecue. Thank you, I bought this. I'm getting error 4 or so sometimes. Do you know how to avoid this? I normally just increase the wattage, and it resolve that when it's very hot. But what's causing this error gangan? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 7:30pm On May 02 |
jstemmanex: Pls my current 8 pcs 250w panels are connected in 4s2p with a 6mm cable.
Can I safely connect all in series with same cable without having to upgrade to a 10mm It's even better to connect all in series than your current setup. Since you will be dealing with lesser current. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 8:24pm On Apr 22 |
justasitis: Fred Infrared Cooker, it costs between 40-50k depending on where you’re buying from and comes with a steel for grilling or barbecue. Thank you. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 6:11am On Apr 22 |
justasitis: I told you people that infrared cooler is better because it was innovated after the induction cooker but you wouldn’t listen. My infrared is better in terms of fastness and power consumption. Abeg, which infared cooker are you using? Can you help with a photo and maybe a link? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 7:17am On Apr 14 |
ajabani4allah: I am a little bit confused about this Bulk and floating voltage, is the bulk the same thing as the OVP and float OVPR on the JK BMS parameters? No, bulk voltage and float voltage is to be set on your controller. The OVP in your BMS is to protect against the cells getting overcharged. |
Technology Market › Re: House Clearance Sales.. Come In Here!!!! by bkuranga(m): 6:55am On Apr 12 |
nenergy: Danstar Dual lens Solar Wifi 4g sim CCTV camera
Solar powered and 4G sim enabled. Please don't sleep on this deal.
40k
Free delivery along these routes - ikorodu/ketu/ojota/Maryland/Ikeja/oshodi bus stops How much to send to Kwara? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 6:52am On Apr 12 |
AyarmBoye: i understand as all the loads will be using the power the solar is generating….
I’m hardly at home during rhe day so no loads …. My question is what if the battery get full before I return home I hope the charge controller can cut of the supply to avoid overcharging of the battery? And what happens to the power the panel keeps generating when the battery is fully charged? Bro, it will cut off charging. That's why it's called a charge CONTROLLER. Just like you're the CONTROLLER when driving a car and you won't let the car tumble. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 7:23am On Apr 03 |
Gshems: Something wey you Don already buy? I was about asking the same. |
Technology Market › Re: Samsung S23 Ultra by bkuranga(m): 12:42pm On Mar 02 |
Still available? |
Technology Market › Re: House Clearance Sales.. Come In Here!!!! by bkuranga(m): 9:13pm On Feb 19 |
FutureFocus: More sweet keyboards for your work stations Price for your keyboards? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 7:58pm On Feb 18 |
Tdoctor: Please, can someone explain how one of these is a PWM and the other an MPPT? I think the MPPT is just printed on a PWM inverter. The OGAs in the house will have more knowledge, though. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 10:16pm On Feb 14*. Modified: 1:03pm On Feb 15 |
capnies: The mppt pv input determines the size and connection of your panel
The max mppt pv input is 450v that means look at the Voc of your panels if it 45v it means you can't connect 10 of those panels in series, but you can connect 5 in series and then connect them in parallel 5s2p.
Your mppt is 100A If the inverter handles 48v use 48v settings and you use more panels for faster charging ⁷ For 48v you can use as much as 5800w panel provided the pv input of the setup does not get to 450v
If it is 24v then you can use like 2900w panel with total setup voltage less than 450v
If your panel is 525w you need just 6 in series for 24v and like 12 panels for 48v connected 6s2p
Congratulations Your response come be like that oga way they always type epistle and usually end up saying nothing. He uploaded the inverter specs sheet, and you are saying IF it can take 48V, and co. And you suggested 5s2p? Make he add amp together again when specs sheet say 18A maximum PV input? Spec sheet is clearly saying 24V and 18A max input, boss. You miss am? |
Technology Market › Re: House Clearance Sales.. Come In Here!!!! by bkuranga(m): 2:58pm On Jan 29 |
Omayie: Gbagada estate Are you a business starter or already existing? Already. |
Technology Market › Re: House Clearance Sales.. Come In Here!!!! by bkuranga(m): 10:20pm On Jan 28 |
Omayie: Flairing Tool Solar and charge controller 200Ah battery Supermarket shelves And more. How much is the shelves and location? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by bkuranga(m): 10:38pm On Jan 26 |
Ferdiwar: It balls down to your space as both are of different capacity (1hp vs 1.5hp).
I currently have the older version from your picture of the 1hp thermocool and it's been great in terms of performance and efficiency (between 270w to 490w on the lowest Gen mode). I've not used LG AC so I can't speak to its efficiency. Thank you, I will go with the Thermocool then. |