Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 5:55pm On May 17, 2025
Don't Buy Lead acid in 2025 abeg..
We just replaced a Lead acid with this

It only managed 52,369AH, approximately 261 Cycles less than 2 years e don degrade to 10% capacity cheesy cheesy

Now we have installed 3.6kwh with 1.5kva Hybrid

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 5:51pm On May 17, 2025
bbally:
Hello, what is your review on this firman / itel inverters on inductive loads and surge startup of AC compressor.

Do you have any recommendations on a 4kw/5kw hybrid inverter on 24volts?
You can buy the transformer based. If the Major Load are inductive ones.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 7:03pm On May 16, 2025
BIY installation completed

We are still delivering as at the same time.

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 6:23pm On May 16, 2025
mctfopt:
$71 then. ₦ was so cool then. Oh well.


Before that bought two Fangpusun in 2016. Still kicking today.
That was nice ..the price didn't change much self..
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 11:00am On May 16, 2025
mctfopt:
I have a MakeSkyBlue type of this SCC. That thing refused to die. 2018 and still kicking.
They were not meant to die actually..
You can check the USD you got it then you will know it was not Cheap.
Most want cheaper and last long products now.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 10:22am On May 16, 2025
KudozInteriors:
After this, what next sir?
We will know when you Open
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 10:14am On May 16, 2025
KudozInteriors:
The distributor just said another thing; that he cannot even expose the PRO again and protect us. That after the business is done, we will go home and leave him with the PRO to deal with.
He is complaining that we are involving more people in the case and that it’s pissing him off.

My ogas, please help me.🙏🏼

What do I do now?
Open the batteries, and what is what is inside..
The batteries has been compromised, there is no warranty seal again.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:31pm On May 15, 2025
toscotech:
Do you have growatt inverter 6kva if yes how much
E no dey, we have Deye 6kw 1M sweet device.

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:19pm On May 15, 2025
Juror:
is that a 14kWh battery on the bike ?!
The Guy rugged am oo 14.3KWh Deriy

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 6:17pm On May 15, 2025
Oshomo12:
If I may ask, What exactly do you need? Just list them out: 1, 2, 3....etc
I wish he will collate all the response and post as a Book. At the end of the Research. The book will be best selling for beginners.

He has kuku blocked me grin
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 5:46pm On May 15, 2025
Out for delivery

12V 100AH Taico - 220k
12V 100A LVTOPSUN - 230k

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 12:58pm On May 15, 2025
AndroBlaze:
I said I wasn't going to put mouth in this again, but your wife is wrong.

The installer was part of it, there is no doubt, unless he is truly an electrician and an illiterate, that's the only way you can exclude him.

They likely just removed the cells in the Sukhig battery you rejected and transplanted them into the Sako casing, which is why that battery will even struggle to do the 2.5kw for 100amps sef!!

Please, like I said, make sure the lessons you learn from this experience exceeds the money you've temporarily lost ooo.
They have packed Fufu and Concrete inside the Sako lipsrsealed
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 5:14pm On May 14, 2025
Oem18:
Why?? If you cannot satisfy his quest for knowledge step aside. You yourself did not become knowledgeable overnight.

The research he has made so far on this thread has been quite captivating and will help future newbies.
Research?
The new block feature make sense Sha.. grin
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:32pm On May 13, 2025
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:31pm On May 13, 2025
racerve:
The Pylontech allows for a higher depth of discharge (95%) vs the Deye (80%). On paper at least.

But either option should be fine.
This state is wrong perception, there is nothing like Allow or Disallow.

You can use all LFP from 3.65 to 2.5V. no manufacturer is capping you until you buy a cell that doesn't have full capacity. All LFP have 100% usable capacity.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:28pm On May 13, 2025
ask4bk:
Does a 48v 5kwh exist? How do you join 16 cells to make just as little as 5kwh? Maybe around 100ah sha. That will be rare to find though.
there are 100ah cells, even 86AH, 50AH, 25, 5AH self
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:27pm On May 13, 2025
fuckboys:
chief please what inverter is this that you used for the capacity testing of the 12v cworth battery?
Sako 12V 2kva
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 1:45pm On May 13, 2025
Mrreed:
When you search his moniker, you will see why he shouldn't be taken seriously.
You grab grin
Me self forgot
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:22pm On May 12, 2025
fuckboys:
So after the advice I got from my bosses here, I decided to change my breaker and I saw this.

I've installed a new Schneider 63a breaker, let's see how it goes tomorrow.

Obviously this is a fake dc breaker, I hope this si what has been causing all my charging issues.
I don tell you from get go. Change the breaker.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:20pm On May 12, 2025
Drama everywhere grin
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 7:02pm On May 12, 2025
KudozInteriors:
Please I don’t understand this sir.
Was it installed yourself or an installer assisted? didnt your installer show you these capacity page and how you can check SOC on the screen
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 6:38pm On May 12, 2025
KudozInteriors:
After the first time that the battery was dying fast, I had to click on the buttons on the battery and saw 100ah. Didn’t know what it meant but I knew that the sticker said 200ah. I snapped it and sent to my installer and the vendor. They said it means nothing and that it’s just the charging current but I just knew that the thing was dying fast while carrying my appliances. It’s actually possible that they did not send this to the factory and they kept me in the dark for 2 weeks.

I’ve been good to this guy. Why would he do this to me?
I’ve called him though and he said he’s coming to my house tomorrow.
Still not adding up discharge that batteries to 21V till it shut down then charge again.
That is not a Li-wall.. but Li-Sun.

I got it for someone and it's 25.6V 200AH Li-Sun

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 6:30pm On May 12, 2025
Mavor:
I'm thinking they cost that much because they are higher voltage rated and LiFePo4. I am strongly leaning higher voltage cos they require lower current to operate which means less heat and no fans needed so no battery noise. Your LVTOPSUN is 24V abi?
You mean 48V is High voltage and 24V is low voltage.. you may be right but..

In this context Low Voltage (12V~60V)
While High Voltage System(150V to 800V)
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 4:01pm On May 12, 2025
Mavor:
Experts in the house (HeavenlyBang, Dam5reey1, etc), please help me make a choice between these two batteries. Want to help my sis for a one-bed apt setup - https://sygniteng.com/product/growatt-hope-4-8l-c1-lithium-ion-battery/ or https://sygniteng.com/product/megatank-gl48100-lithium-ion-battery/

Never heard about Megatank before. Thanks in advance.
I wont recommend any of them, they are overrated..

1.8M for 4.8KWH.
When the LVTOPSUN I am using is 2.2M for 15kwh.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 10:18am On May 12, 2025
KudozInteriors:
Oh my God😳😳😳

What have I gotten myself into?
Your load is obviously consuming the batteries. Post screenshots of the percentage on the batteries and voltage also the current when you are discharging and Charging.

You dont need to be looking at 1 bar 2 bars or 6 bars.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 10:13am On May 12, 2025
HeavenlyBang:
70w fan + 45w = 115w
From 10pm to 8am = 10 hours = 1150wh


Assuming three phones charging at 30w for three hours = 270wh

Total is 1420wh

Even considering inverting losses, total DC usage shouldn't be more than 1600wh, and yet he's losing ~2500wh.

I think the discrepancy is enough to chalk it up to a bad battery.
So the house was in Black out..
His needs to pay attention to details.
This batteries in questions is not anyhow batteries, it has communication as well as Screens that shows Current consumption but he decided to use Bars when BMS shows SOC in it's screen.
He should show what the Batteries current displays and at what percentages.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:05am On May 12, 2025
HeavenlyBang:
SAKO is garbage, no one recommends it here anymore for a reason. Send that battery back and get your money back.
You for at least add small technicals small.
I was planning to make videos about importance of efficiency in our inverters.

Reason why I attached an External Shunt permanently to my Batteries..

His is using an Inverter that consume 45w and plus other loads.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 9:02pm On May 11, 2025
fuckboys:
Please who sells the original of this here?
That's so fake,
I use 63A TOMZN and it's well built..
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 9:00pm On May 11, 2025
fuckboys:
Dam5reey1

Twice I’ve tried quoting you I chop ban, what’s going on? huh

SMS has a 12 2kva inverter with max pv 400v and 80a mppt cc
Eheh.. I don't know why oo.

Last time I used that inverter the user complained about interference. So I cancelled it from my recommendation.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 6:34pm On May 11, 2025
fuckboys:
what really baffles me is the controller goes as high as 800 plus watts on a 12v system.

I saw 800w watts today before it tripped off.
More reason why you will only find 1000w on 12V Hybrid with 60A CC.

You have oversized the PV to X2 of the rated capacity at 12V

The battery just there to receive whatever comes from PV and CC.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 4:17pm On May 11, 2025
fuckboys:
I'm not sure but i went through the manual of the inverter, it doesn't support more than 200ah battery,

It has just charging profiler of 50ah,100ah and 200ah support.

But my new battery is 280ah. I guess that's why it's not charging, I'm not sure sha.
What was the size of the old Batteries and if it's Lithium ion phosphate batteries..

It may be that your old batteries is not taking as much current as this new one.

I charged that batteries at 60A without issues.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 3:42pm On May 11, 2025
jonescosmos:
One of the reasons I stayed stuck with Deye.
Very interesting something ooo grin
4800W + 4800W confirmed. Cause I saw 4800w briefly on a single String.