DIPUU2LIFE's Posts
Nairaland Forum › DIPUU2LIFE's Profile › DIPUU2LIFE's Posts
thanks for your love ;d
|
THANKS FOR VIEWING. QUALITY IS EVERYTHING.
|
@ your service, nationwide. Quality Perfectly controlled.
|
WE ARE STRUCTURAL STEEL FABRICATORS. WE DELIVER GOOD QUALITY STEEL, FABRICATED TO SPECS AND INSTALLED PERFECTLY. OUR PRECISION IS PERFECT. WELDED, RIVETED, BOLTED CONNECTIONS, ETC. OUR FABRICATORS ARE CERTIFIED AND EXPERIENCED. CALL 08033186563 08182280861 engineerosibajo@yahoo.com
|
@ obua yes, but with an affordable fee if we are not partners on the bid. we assure you of total consideration of all costs from design to completion. we leave no stone unturned. |
SUPER QUALITY CONTROL NO ISSUES WITH STRUCTURAL CONSULTANTS AFFORDABLE OFF-SITE AND ON-SITE FABRICATIONS WELD TESTING JUST NAME IT. 08033186563 |
WE ARE STRUCTURAL STEEL FABRICATORS. WE DELIVER GOOD QUALITY STEEL, FABRICATED TO SPECS AND INSTALLED PERFECTLY. OUR PRECISION IS PERFECT. WELDED, RIVETED, BOLTED CONNECTIONS, ETC. OUR FABRICATORS ARE CERTIFIED AND EXPERIENCED. Call to get more info. 08033186563 08182280861 DWAINZ ENGINEERING SERVICES Regards Engr. Oladipupo Osinbajo. (MNSE, MNIStruct.E., MNICE, ASQ CQI, ASQ; CQI, CMQOE, CQA, SSGB., ISO 9001 Lead Auditor) Cell: +234 (0) 8033186563, +234 (0) 8182280861, +234 (0) 7046314173 Email: dipuu2life@yahoo.com engineerosibajo@yahoo.com
|
ABOVE ALL, I think this structure require a physical examination and interaction with the supervising engineer so that the quality and procedure used can be know. Thanks for your response and your attempt to understand the situation given the little information you have. I am not in charge of the building, and i can never make a mistake like this. I'm too much for it, and yes i have good structural experience. What happened there was that a group of structurally deficient white guys decided to to run a lintel across without taking proper construction joints into consideration. the actually stopped the first cast of the lintel on the side of the column. then drilled in 16mm dowel bars into the column to hold the entire span in place. the span in quite long for a 230 deep beam. it would deflect upon loading. Right now, the beams are on props that are also on the ground that has low cohesion, so there was bound to be an expected insignificant settlement. but in this case, the shrinkage and slight settlement of the props has set the failure in motion. i expect that once the lintel in de-propped, it should meet with the ground 'cus the shear at the edge would be great as the beam is not acting as a continuous beam because of the cold joints. Please note that there is no wall directly underneath that can help. there is a window spanning column to column. Though the concrete tests give not less than 30, it has nothing to do in this case my brother because apart from the shear, under load, the concrete beam would want to pull away from the column and as such the reinforcement should take over. but there are no significant reinforcement in place, remember i said the reinforcement were drilled in. To solve this a prop at the middle might work, but its been instructed to be pulled down. did you also notice that the beam above, which is meant to support the steel rafters have also been stopped at the column position. this is a treat to the beam as it would crack over time at the top were most of the moment at the support ought to be resisted by the reinforcement which cant work in composite with the concrete because of the location of the construction joint. the top reinforcement is also short. I mean these are some really mean construction people, with no regard for structural engineering principles. CASTING PLANS On the overall what is to be learn here is that a proper construction casting plan ought to be made on all structural elements that cannot be cast at once or is too long. the casting plan would show the volume of concrete involved, the surface area, lengths, widths, construction joints with distances to the supports, expansion joints etc. this would be assessed by a structural engineer and modified if necessary. casting plans are very important and follow certain aspects of relevant BS Codes. construction joints are always calculated to fall into points of contraflexure. POINTS OF CONTRAFLEXURE In a bending beam, a point is known as a point of contraflexure. it is a location at which no bending occurs. In a bending moment diagram, it is the point at which the bending moment curve intersects with the zero line. Knowing the place of the contraflexure is especially useful when designing reinforced concrete or structural steel beams. it is also useful when deciding construction joints. the same goes for slabs etc. The lengths of reinforcement specified on structural drawings are to remain until otherwise modified by a qualified structural engineer. I am sure a few of us are familiar with this principles. I only brought it into this forum so that we can share a lesson or two from this with many others out there without the understanding. I appreciate your response and it shows that you may well be the only courageous person on this forum to respond with the approach of someone fully aware of construction practice. thanks my brother. |
A promise of 30% return on investment in not impossible in Nigeria. But you have refused to release my post and deprived nairalanders the opportunity to achieve their primary aim on this site. I am a civil engineer and fully into construction practice. i have never been a fraud and will never be. i have been registered for quite some time and have contributed mostly on engineering issues under the property section. i am here in money, to introduce my project and bring it to clients outside the construction industry. Please my post is very possible. the actual ROI on my projects have been close to 200% p.a. By introducing it to the public at 30% is actually far towards the safe side. Please allow my posts. It happened again yesterday and i have since sent a mail. i expected you to have released it. i have not heard from you Return my posting rights please. I believe you have my email and you can also connect me on 08033186563 Thanks. |
![]() ![]() Engineers? Architects? Builder? Whats the reason for the crack at the column points, with the props are still in place Reinforcement? Concrete? Workmanship? What? Note: to see the pictures better, hold down control and scroll mouse. engineer.dipo@yahoo.com 08033186563
|
HOPE YOU EAR MAKING GOOD USE OF MY ADVICES. @SEGUN, Still expecting the soft copy of your soil test. Piles are designed, shape and dimensions of pile caps are not just assumed. a stitch in time saves nine. the free advice i gave you extends to a free design of your foundation. |
This is totally free. No hidden charges. Call me before making civil engineering decisions. lets discuss it, to reduce possible errors. I am qualified and experienced enough to handle your seemingly difficult civil engineering, construction, issues. Conceptions, Analysis, Designs, Construction, Supervisions, Inspections, QA/QC. Name it. I'll point you in the right direction. A trial will convince you. engineer.dipo@yahoo.com 08033186563 |
You know?, the best way to sell a product is to also have it appeal to us visually. Interested. Would like to see a picture of this. Please send to my box if you have it. dipuu2life@yahoo.com |
i am in desperate need of a list of construction companies in Nigeria, what exactly they do, emails, websites, the size of contracts they can handle, etc. it would be a life saver to get this list. my life depends on it. SOS. 08033186563, dipuu2life@yahoo.com |
Calibrate your diesel/petrol tanks precisely, accurately, & at an affordable price. It will then be easy for you to determine the actual quantity of diesel/petrol supplied to your tanks. You will be surprised at how much you are being cheated. Avoid arguments with diesel suppliers and facility managers. Determine the quantity you use on a daily basis. You will get your calibration charts and the installation is fast and simple. . Included here are pictures of a particular case of a typical tank for a company being regularly cheated of about 300litres per supply. 08033186563 You'll see in this picture the finger of the boy at the actual location of 2000litres of diesel and an already marked red 2000 litre mark being used by suppliers. the entire tank is less than 4000 litres, so if its to be filled according to the suppliers quantity, they would have filled it as a 7000 litres tank. there have been cases of; 900litres tank being supplied as 1,000litres 2,000litres tank being supplied as 4,000litres 5,000litres tank being supplied as 10,000litres 16,0000litres tank being supplied to about 3/4 as 20,000litres lets do you an independent inspection and calibration. its much easier and offers you peace of mind. D'wainz Engineering Services 08033186563 feel free.
|
I NEED TO LAUNCH A BEACH PARTY WEBSITE. I NEED SOMEONE TO HELP ME WITH THE DESIGN AND HOSTING. SEND ME YOUR COSTS AND PROPOSAL TO dipuu2life@yahoo.com +2348033186563 |
I NEED TO HIRE A BUS THIS WEEKEND. HOW MUCH 08033186563 from lagos to ogun state on saturday 23 October. get in touch asap with vehicle, price and picture if possible. dipuu2life@yahoo.com 0803 318 6563 |
want you to design it toward one that i have seen online. you have not answered my question of price and duration |
i want to design a website for a construction company. how much. i have all the information and picture necessary for the job. i need you to get this information online for me on a good web theme. advice me? thanks. dipuu2life@yahoo.com 080=33186563 081=82280861 |
i need to learn revit, especially revit structures for engineering design purposes. please contact me if you are able to teach me or have any information about the training. thanks. dipuu2life@yahoo.com 080=33186563 |
Would like to purchase a portacabin for use as temporary site accommodation. This should have in it toilet and bath and be at least 8ft wide. Call me about any information. New or used. 08182280861 08033186563 |
Would like to purchase a portacabin for use as temporary site accommodation. This should have in it toilet and bath and be at least 8ft wide. Call me about any information. New or used. 08182280861 08033186563 |
Would like to purchase a portacabin for use as temporary site accommodation. This should have in it toilet and bath and be at least 8ft wide. Call me about any information. New or used. 08182280861 08033186563 |
Thanks naiajacutee for your suggestion. Was in contact with the guy, but no responses yet. Don’t want to look too desperate with him. Would appreciate any other info. Thanks. Still looking. dipuu2life@yahoo.com |
Would like to purchase a portacabin for use temporary site accomodation. this should have in it toitel and bath and be at least 8ft wide. call me about any information. new or used. 08182280861 |
ha!!! no geologists in the house? |
SOIL TEST NEEDED FOR A RESIDENTIAL BUILDING IN ANTHONY VILLAGE, way into the sherlaton hotel side of anthony village. If you can do this, please contact me with details of rates, duration, etc asap for at least 2 penets and 1 bore hole. dipuu2life@yahoo.com 08033186563. |
