PhonesRe: The Xiaomi Thread. by Feshizzy(m): 11:43pm On Jun 15, 2017
Dam5reey:
Feshizzy, I hail oo.. Which broker do you trade with?
My brother I greet you sir,
Instaforex currently!
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Feshizzy(m): 7:05am On Jun 14, 2017
pranil:
Min charge rate for lead acid is c10 which means for four sets you need min 80 amps over 12-14 hours ( assuming round trip efficiency of 75 %)

But please use quality DC isolators like schider not teh knife switches meant for AC application as they can spark and weld the contacts . Solar Depot carries them

The problem with using multiple chargers on the same battery bank will be high DC ripple leading to premature failure of batteries or inverter unless you use quality chargers like victron I would advise getting a larger inverter

The batteries are l also large with 5 KVA ( 4 KW) load also it will take almost 8-9 hours to reach 50 % DOD . If you are really consuming 4 KW continuously I would advise getting a larger inverter as most inverters are most efficient and run much cooler ( longer life) at 50 to 75 % loads

I have seen Prag 8 KVA rated at max 100 amp and new Ipower 5KVA from Zinox rated at 80 amps . ( on Grid chargers built in the inverters )
I doff my hat sir,
But with dc isolators will be mostly used when the batteries want to be charged,

My understanding of such ripples is when a circuit is having different charging source and charged at the same time!

But in this case, the isolators have separated each pack from the rest pack,

Can such ripple still occur?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Feshizzy(m): 11:47pm On Jun 13, 2017
emmaniche:
Please help house.

Can a 5Kva inverter support 16X12V/200AH batteires, how long can it take to chargethe whole batteries?
My brother even if na 200 batteries you wan add no problem,

Based on logistics,

As you see,
Most 5kva inverter na 48v meaning four batteries in series,
So e go be 16/4 which go give you four battery pack.

Meaning say you connection go be 4 x4 grin grin

My candid advise if you wan use nepa light charge them,
Na to first, you something like a knife switch wein you go fit the use separate each pack for charging and combine them all for usage,

Eh! E possible, but small work go dey am.

Now back to the matter!
Well, for the charging I would advise you get 3 48v 20/30a charger for the extra 3 packs, as the first pack would be having it's charges from the inverter directly,
Charging time with my recommendation would be 8-11 hrs all packs would be full.

This is based on the fact you intend charging with power from the grid,

But for solar setup,
I leave you in the hands of our ogas at the top! cool
Technology MarketRe: Scuit: Shop & Ship From China, USA, Dubai & UK (Express, Cargo & Shipping) by Feshizzy(m): 1:02pm On Jun 13, 2017
BizBloke:
[color=#000033]$220 per CBM, Feshizzy.

The least amount we can quote if you've got lower than that is $110 [we'll waive the Service Charge too].

Cheers![/color]
Thank you sir for your response,
I would get back to you with more item to fill the space! smiley

Regards!
Technology MarketRe: Scuit: Shop & Ship From China, USA, Dubai & UK (Express, Cargo & Shipping) by Feshizzy(m): 11:50am On Jun 13, 2017
BizBloke:
[color=#000033]Hi Feshizzy,

Thanks for the information. Nonetheless, for shipping, dimension is too vague to work with. Please get the CBM value.

Thanks.[/color]
How much do you charge per cbm?
0.1 Cbm Sir!
Thank you sir!
Technology MarketRe: Scuit: Shop & Ship From China, USA, Dubai & UK (Express, Cargo & Shipping) by Feshizzy(m): 10:38am On Jun 13, 2017
BizBloke:
[color=#000033]Hi Feshizzy,

To get an accurate rate on that, please provide the CBM value. Shipping doesn't work with kg.

Thanks.[/color]
It's just on piece,
The dimension is (29xx25.5x12)cm
Science/TechnologyRe: How To Create A Locally Made Inverter With Ease by Feshizzy(m): 9:57am On Jun 13, 2017
officialfestus:
am tired of the 3hours on 21hours off,since 2days now we are in total blackout.....thank God for my solar phone charger which i have been using to charge phone and other gadgets..but the charger is a bit slow though,and am thinking if I can connect a 12 volt 1ah car charger to it....so here's the plan ......
2x 5.2 volt 200ma solar phone charger
1 12volt 1ah car charger
cigarette lighter
2 5.2volt solar phone charger to be connected in series to make it 10.4 volt then connect the cigarette lighter to the solar phone charger, follow by the car charger.....
pls gurus in tha house will it work?
Check the voltage tolerance/variable for the charger .

I'm aware of most 12v system,
Has tolerance from 10.5 to 14.5v
And ac current from 180 - 265v

So my advise is to check it tolerance first for each appliance,

I have power share two 12v dc fan to a 24v supply,

To my understanding,
If your charger meet the acceptable voltage range then it should work fine,

Cheers!
Technology MarketRe: Scuit: Shop & Ship From China, USA, Dubai & UK (Express, Cargo & Shipping) by Feshizzy(m): 9:28pm On Jun 12, 2017
BizBloke:
[color=#000033]Hi Feshizzy,
Welcome to Specuit Cargo.

$112.50 plus a Service Charge of $3 via Standard Freight.

Thanks.[/color]
Thank you sir for your quick response,
How about through shipping,
That one that takes over a month?
Technology MarketRe: Scuit: Shop & Ship From China, USA, Dubai & UK (Express, Cargo & Shipping) by Feshizzy(m): 3:21pm On Jun 12, 2017
BizBloke,
If I was to import a $100 stabilizer of net weight 15kg from Alibaba,

How much would it cost me to land it to Lagos?

Waiting for your response!
Technology MarketRe: MAKE ORDER, WE SHIP 4 YOU, BUY FROM USA/CHINA ebay,amazon,$4/Ibs MAYORALL by Feshizzy(m): 3:20pm On Jun 12, 2017
Mayorall,
If I was to import a $100 stabilizer of net weight 15kg from Alibaba,

How much would it cost me to land it to Lagos?

Waiting for your response!
ComputersRe: Inverter Users : Lets Have Your Experience by Feshizzy(m): 12:53pm On Jun 12, 2017
zeestone99:
50k pure sine wave with transformer, call/whatapp 08117398294
What's the power rating on the inverter sir?
EducationRe: MY NIPOST EXPERIENCE - Nigerian Postal Service by Feshizzy(m): 11:51am On Jun 12, 2017
Can I send a stabilizer from asia through nipost?

Weighs about 15kg!

Please what are the process of acquiring such item?
Any custom duty on it and how much? Or how is is calculated?
BusinessRe: Simple Steps On How To Import From China by Feshizzy(m): 11:28am On Jun 12, 2017
Can I send a stabilizer from asia through nipost?

Weighs about 15kg!

Please what are the process of acquiring such item?
Any custom duty on it and how much? Or how is is calculated?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Feshizzy(m): 2:57pm On Jun 09, 2017
Who could help point me in the direction/video on insulating lighter load to th inverter from a distribution board DB,

I would be very grateful,
Thank you!‎
ComputersRe: Inverter Users : Lets Have Your Experience by Feshizzy(m): 2:57pm On Jun 09, 2017
Who could help point me in the direction/video on insulating lighter load to th inverter from a distribution board DB,

I would be very grateful,
Thank you!‎
Science/TechnologyRe: How To Create A Locally Made Inverter With Ease by Feshizzy(m): 2:52pm On Jun 09, 2017
Calebeslove4u:
[/color]

ok, i have this APC 650 UPS (390W), can i connect a load of 300w to it? (say 32inch tv,bulbs,and fan)
You can give it a try and tell us,
If it works, good for you,
If it doesn't, the ups would trip off,

There are sometimes I forget to turn off my electric kettle before switching on my bluegate 1.5kva ups,
What happens is that it trips off!
All I do is switch of the kettle and off and on the ups!
Science/TechnologyRe: How To Create A Locally Made Inverter With Ease by Feshizzy(m): 12:50am On Jun 09, 2017
Calebeslove4u:
[/color]


na wa o, i never use am reach one week sef, last night d thing just started blowing my bulbs one by one, i had to give it more load by putting on d tv and home theater


Ups no fit blow bulb at all,
Probably there's something wrong with your connection or the ups is very bad,
Either way,
Get a new one make you for get rest of mind!‎
Science/TechnologyRe: How To Create A Locally Made Inverter With Ease by Feshizzy(m): 12:45am On Jun 09, 2017
Calebeslove4u:
my ups is making an odd sound (like; wooooooooooooo....) and i dont understand why. it started last night. but if i add more load, say i put on my 65w fan, d sound will reduce a bit.
please gurusin d house, any one with an idea of what d problem may be?

cc: ceejay

To me the sound is normal,
It means the transformer is at work,
But if you have been using it awhile and the sound don change,
My advise is to get another ups,
And probably install a dc fan inside it to cool am,
Transformer get hot during operation,
And some ups are not properly vented or where you keep am breeze no dey blow am well.
This is why it is also advised to add a dc fan to it,
Make e dey help am cool down

Cheers!‎
Science/TechnologyRe: How To Create A Locally Made Inverter With Ease by Feshizzy(m): 9:07pm On Jun 03, 2017
Calebeslove4u:
i have finally completed my own set up, 100ah battery, 1.5kva ups, 40amps suoer charger...... i got 3watts energy saving bulbs here in Portharcourt, i also bought d battery here.
thanks to oga ceejay and every one that is making d thread a success
How much was the costing for this setup Sir?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Feshizzy(m):
[quote author=Barezzi post=57010847]Mr Seun. A lot still need be done to improve content creation here on Nairaland. The current setup can be very frustrating.

Use this link,
https://www.nairaland.com/fta

Use your browser to search for "mod"

Message anyone you see there,
I have also been unduly banned something too,
I do message the mod in charge of a thread and they are sure to resolve the ban in due time,

You can be banned and still be able to PM these mods

Also try oga lala and mynd44 too.

I believe they are supermods.

Cheers!
Regards!
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Feshizzy(m): 7:36am On May 29, 2017
efuro:
A re-visit of picture of ur panel and from a DIY point of review of ur installation, I believe it is sufficient enough to give u the needed energy production. what I find odd is u don't have to peel off the black back of the cable. ur cable size is very ok but why peel of the insulating back?

anyway, 40A Cc is thoughtful, the culprit is ur power bank. the PWM CC goes down to the level of ur ba3 & gradually rise or regulate the voltage/amps to ur ba3. unfortunately ur ba3 are not good thus you keep recording low figures which will grow worst till u replace dem.

with ur present state, I advice daytime workloads & nighttime for led bulbs / phone charging only.

my regards!
Thank you once again kind sir,
But I'm more concerned with the position of the panel,
If they are well optimised,
I know the banks and building are weak,
The total harvest was 24ah,
While it was generating 1.4ah
That is less than 30% of the panel rating at peak performance,
I was expecting a generation of about 4 - 5ah during peak period!
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Feshizzy(m): 9:00pm On May 28, 2017
efuro:
welcome to the forum.
on ur question, it is a pity the information u provided is still scanty. u need to do more.

eg. cable size, make of PWM, ba3 type/bank @ 12/24/48 etc, inverter type. it is a DIY setup etc etc.

how did you size ur bank & refill it up at sunrise before complaining the ba3/inverter indicating low voltage quickly.

mind you with little patience u get help soon ( b/cos u have 3 groups in the house- the DIYs like me, professionals, &marketers)

the DIYs are always ready to help base on their knowledge/limit of experience.

the professionals are simply tired of helping or are keeping certain basic info as trade secrets.

finally, marketers are there for all with after sales advises.

if you're convinced you're not getting enough from the house, pls check YouTube there u have thousands of video on various topics on solar. enter ur comments/questions, ur sure to get help.

cheers!
Thank you very much sir For your response,
What I actually need was the correct positioning for the panels,
As it is already positioned facing east as in relation with the roof,

The inverter,
Is a mercury 2.4kva inverter with two very weak 12v 100ah batteries,

And the wiring was done by one very wack techkie using about 10mm cable for about 10 yards

The solar is on the opposite on the roof of a 3 storey building while the cc is on the 2 storey of the building very close to the inverter/battery,

For the controller, it's a cheapo pwm CC of 12/24v 40ah capacity,

Thanks in advance though.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Feshizzy(m): 2:57pm On May 28, 2017
Good day everyone,

Abeg make una help me out!

We got one 250w 24v mono solar panel
With a pwm solar CC,

Because of how the roof is,
It is facing the east,

And at 2:00Pm it was producing 1.4ah when we checked the CC,

Please note the battery on the inverter was very very low,

Please any possible way to optimise more abit?

ComputersRe: Inverter Users : Lets Have Your Experience by Feshizzy(m): 5:11pm On May 20, 2017
adanny01:
Charge each battery to 100% state of charge.

Test the voltage of each one with a multimeter. At full charge, 12V battery should read 13.7Vdc.

Get a DC load or use a battery load tester. Connect one battery for a period say 30mins. Then record the final volt. And repeat process for the second battery. Compare the voltage drop for the 2 batteries.
Then what next?

You forgot to mention recording voltage after 3 hours state of rest of charge/discharge also!
ComputersRe: Inverter Users : Lets Have Your Experience by Feshizzy(m): 12:46am On May 19, 2017
tziz:
Wow!
So wat if i individually use n discharge the batts den connect in parallel and start a fresh charge? I dnt wanna short-circuit dem cos dt mite cos a problm.
Get something similar to a charge over switch to alternative the battery and use one at a time,
That way, you discharge them and recharge them separately,
Like I said before,
The capacity/resistance of the batteries now differs!
And can't be used together,
As it would shorten both batteries life!

Note that:
When changing/switching batteries always have your inver switched off! No sudden/sharp movement in dc side,
It can be expensive wink


Attached is sample of such changeover

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Feshizzy(m): 4:31pm On May 18, 2017
Barezzi:
Buy a small DB and move such opportunist loads to it. Size it so your timer can carry the loads. Use an Automatic transfer switch to seamlessly alternate between PHCH and your inverter. See attached.
Thumbs up mate!
This is the best way to go about it,
Very smart!
ComputersRe: Inverter Users : Lets Have Your Experience by Feshizzy(m): 11:35am On May 18, 2017
tziz:
So iam getting a 2nd pre-owned 200Ah Batt, the first one is very good, it read 13.5V on my multimeter, must i get an identical reading on the 2nd batt? I Mean to prevent bottlenecking d 1st one. Since they hav to be equalized. Plus, if say the 1st has 50% charge power and the 2nd one has 100% charge power, is it ok to go ahead n connect dem 2geda?in parrallel..
It would be nice if you could build a circuit to hand both separately,
By using on battery at a time and also charging one battery at a time,

The reason is that,
Your first battery would have less capacity than your second.

For the analysis we would use the water can experiment,
For example,
At charging,
you have a big can and small can,
When you pour water into them at same rate the smaller one get filled, while the big one get partly filled,
Since they are both connected together,
At idle mode when not in use,
The big one would try to equate the small one by forcing more water into the small one making it to overflow or energy loss.
At discharging time,
When you pour out both at same rate, its obvious the small one would finish first,
But it doesn't end there,
The big one begins to supply/charge the small one and supplying power at same time.

In conclusion,
You would be killing the bigger battery during discharge, and killing smaller battery during recharge,

This is just my view though!
I stand corrected in this though grin grin

Cheers!
ComputersRe: Inverter Users : Lets Have Your Experience by Feshizzy(m): 1:09am On May 18, 2017
adanny01:
Lets be very practical and go back to basics.

From physics, the relevant formula to this matter is
Power (P) = Current (I) x Volt (V)
P=IV

The man has 2 x 100AH = 200AH on a 24V inverter connected in series.

Remember that connection in series, voltage increases nd current remains same.

Power =24V x 100AH = 2400Wh

This battery has the capacity to store 2.4kWh of energy. A charger must be able to produce this energy for the battery to store.

So what charger does he have? He has a 20A charger. This means the charger will be able to provide

P = 24 x 20 = 480w

It means that what ever his source is, whether NEPA or generator the charger will be drawing not more than 480watts per second and depositing in the battery.

The math continues
2400Whr /480W = 5hrs

The battery will be full in 5hrs.

It means that any source of AC supply, the charger gets to draw 480W.

In your case, you didnt mention the current for the luminous but i assume its 20A.

Power will be 24 x 20= 480w same as above. Your generator which is actually a 2000w generator (generators of 2500-2900va are 2kw while 3000-3700va are 2.1-2.3kw) will carry this load with ease. Like i noted in my last post, this will depend on other loads on the generator and additionally the state of your generator. Also, this power 480w is 24% of the capacity of the generator.

For the Mustpower which you said 48v x 30A=1440w. This is 72% of the capacity your generator, that is excluding any other load you might have connected to the home. This is not even taking into consideration the serviceability state of your generator to carry such a heavy load.

With this, i dont expect your 2.5kva generator to struggle to power that mustpower inverter especially if connected through your home with other loads and losses.
Wise speaking Mate,
I was about to explain same thing too,
But you took the letters right of my keypad, grin

I support all that you have said completely you said my mind,

Just to top it up a little if you don't mind, cheesy

Oga @earthrealm,
You have also spoken very well,
I actually like your view for being more practical,
But our calculations also are based on real life too.

Point to note,
When converting from kva to kw, a 0.8 power factor is noted,
And also when dealing with current we also work with efficiency due to heat/loss and length of cable which is varies to from 0.6 to 0.9

For your small Gen,
Of 2500va can actually produce,
2500 x 0.8 = 2000watt of power,
And let assume actually efficiency of the gen is 95% or 0.95
Which brings us to 2000 x 0.95 = 1900watts,

For your 4kva 48v mustpower inverter with 4 x 200ah batts.

Noting also, charging voltage is 14v x 2 =56v
And current is 30a
Would give a sum of 56v x 30a = 1680watts

Do note that dc-ac or ac-dc there is always energy/heat loss and not always 100% efficient because the internal component like the transformer and it's cohort sef go receive share for the power,
Thank you for correcting me on this part!

Thereby noting that your efficiency is atleast at 90% or 0.90
Would bring us to 1680w ÷ 0.9 = 1867w
The extra watt to this is known as payment for energy conversation or owo ile. grin

Now for your generator to last you without stressing it,
You need your load to be at 80% load
1900w x 0.8 = 1520w

Meaning that your Generator can carry 1520w load without going into overloading.

Now your inverter requires a starting power of 1867w and your generator can effectively provide 1520w of power without tripping off,

Now you see why your generator is coughing!

For your 24v 1500kva luminous inverter with 2 x 200ah batts.
Divide your bigger inverter load by 2 = 933.5w

Oga architectdre,
Thanks to earthrealm and adanny01,
A conclusion has been reached that small generator can't power your inverter effectively at all at all.

I was wrong for neglecting power factor and efficiency!

Kudos to earthrealm for practical insight!
Science/TechnologyRe: How To Create A Locally Made Inverter With Ease by Feshizzy(m): 1:53pm On May 17, 2017
Donald3d:
army arena was the same place i bougt it,it worked perfectly while it did.Have an idea of the rough estimate of repair cost?
I don't really know bro,
But have you checked it for blown fuse?
There's quite a number of people here with blown sueor charger,
Hopefully they come out soon to tell us how they fixed theirs.

Regards!
ComputersRe: Inverter Users : Lets Have Your Experience by Feshizzy(m): 12:36pm On May 17, 2017
adanny01:
I will just add that he should note that this is just power needed to charge batteries exluding power need by any appliance connected to the inverter especially if the load will be on inverter mains bypass.

It means, that a tv, home theatre, lights or fan load during charging goes directly to the generator by mains bypass design.

Say LED tv 60w, home theatre 30w, lights 3 x 20w, fan 60w, laptop 60w in total 270w. Whether these loads are on the inverter or the entire house mains, they fall back as load to the gen if the gen powers the entire house.

Generator required must be above 560w + 270w =830w. This will be beyond "i pass my neighbor" generator. I would suggest 1500w as minimum.
True,
You are right,
1500w is cool,
My suggestion goes mainly if he already has a small generator,
But if he intends to buy any, he should good for generator with a minimum of 1500w power not peak power rating oo! grin

As for the load,
I already stated it in my post, thank you very much for further clarification!

Which is quite fair, so long you only use the generator with just lighting bulb and no much load during the period of charging the battery.

Just to be safe,
Anything abit bigger than a small tiger generator should be fine.


Cheers Mate!
BusinessRe: Forex Project $50 - $1000!!! Join Me For Live Trading Here! Free $50 Account! by Feshizzy(m): 1:28am On May 17, 2017
[quote author=danberg post=56587480][/quote]GoodLuck with your project!
If you could do this,
Then you sure have mastered this trade.

But really,
What's your forecast of this wonderful dream,
As they say "a goal is a dream with a deadline"

Cheers Mate
ComputersRe: Inverter Users : Lets Have Your Experience by Feshizzy(m):
architectdre:
I have a 2.4kva mercury inverter with 2 200amps batteries that ive been using for about a year now...im thinking of buying a generator to charge the batteries as the power supply is now worse. pls what size of generator will charge the batteries efficiently without damage?
Just think about it,
You have 200ah battery connected in series would give you 24v x 200ah = 4800Wh

But note that most inverter recommended charge settings shouldn't exceed 10% to 13% of the battery capacity meaning your 200ah would need at most 20a draw during charging,

So maximum charging current would be:
24v x 20a =480W

Meaning your inverter requires 480W of power to charge it batteries,

Smallest tiger generator is 800W

Meaning you would be using 480/800 x100 = 60% gen power

Which is quite fair, so long you only use the generator with just lighting bulb and no much load during the period of charging the battery.

Just to be safe,
Anything abit bigger than a small tiger generator should be fine.

Cheers!


Edit:
I just remembered that charging voltage is always higher than 12v, around a maximum of 14v x 2 = 28v
So considering maximum factor of 28v during charging would be 28v x 20a = 560W

I would leave you to do the remaining maths! grin grin