Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 2:58pm On Feb 07, 2018 |
On a cloudy day
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 2:56pm On Feb 07, 2018 |
The finished product
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 2:53pm On Feb 07, 2018 |
Since i changed inverters, the MSW inverter has been lying idle.
one day, I was bored and decided to add the inverter too . .
so i can now switch between 12V modified sine 800va and 24v pure sin3 2000Watts inverter at my will. . .
the battery can serve as both 24V and 12V at the same time..
don't ask how i did it, I nearly burnt the whole house.
before i finally did it;thanks to some resistors.
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 2:49pm On Feb 07, 2018 |
More pics coming, stay tuned
Meanwhile, I had added more panels on the roof;but don't have a picture this time of them. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 2:48pm On Feb 07, 2018 |
The the battery box . . . i constructed myself 100% Contains 4 batteries and has another floor that can take another 4 can be stacked on each other or put sideways . Battery box is ventilated at the top and rear hydrogen gas escape during charging Can be modified to add a padlock; lol 
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 2:44pm On Feb 07, 2018 |
...
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 2:42pm On Feb 07, 2018 |
Oops; i forgot the MPPT Epever 40A addition to replace the pwm cc
you can spot the small black dc fan; to cool it down . .
#nothing_left_to_chance
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 2:40pm On Feb 07, 2018 |
Then came the battery bank; 2 banks in 1; deceitfully connected via black-hat methods.
Along came the Pure Sine wave 2000Watts 24V inverter; as quiet as graveyard.
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 2:34pm On Feb 07, 2018 |
Then came the timer switch for deep freezer
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 2:09pm On Feb 07, 2018*. Modified: 2:35pm On Feb 07, 2018 |
Started out like this ...  Installed by my good friend . . everything else, i did on my own 600W poly panels; 1 x 100Ah battery; 30A pwm cc; 1kVA (more of 800VA) modified sinewave inverter the inverter hums for Africa .. people thought I had a transformer in my house lol
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 1:48pm On Feb 07, 2018 |
Eye candy . . 100% DIY coming soon |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 1:42pm On Feb 07, 2018 |
viperVIP: is there any installer here who is close to Iwo, Osun State?? cc zeestone99 he can go anywhere if the price is right |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 1:41pm On Feb 07, 2018 |
post above: budget 2M lol |
Car Talk › Re: QUIZ!!! For The Week by makavele: 12:37pm On Feb 07, 2018 |
Number 2 counting from the left . . seems to be leaking !
i guess bad o-rings
engine will be flooded |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 9:02pm On Feb 06, 2018 |
mank1234: Question for honourable lithium users: Assuming one already has Morningstar MPPT charge controller and he or she decides to incorporate lithium battery, how will the charge controller charge the lithium battery since it doesn't not have settings for it? Does lithium also use three stage charging algorithm? How do you incorporate with existing infrastructure? You can always create a new charging profile for each individual battery type. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 3:40am On Feb 06, 2018 |
efuro: DIY stuff not a rule
I currently have SLA batteries and GEL batteries joined as one bank (both lead acid anyway). I set my absorption at 14v and floating to 13.6v. I can't equalize gel batteries @ 30v so I had to extend my absorption to 4hrs which works fine after testing 2hrs.
My overnight load is 140-200w and still have 65-70% in my batteries by morning. I run 24hrs TVs, DStv+strong+startimes nite or day. Freezer+fridge off 4pm to 9am. Finally, I get about 5-6hrs of grid a day which is irrelevant if it comes during the day. How is your microtek serving you ? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 12:39am On Feb 06, 2018 |
mank1234: Which of flames, Myhome, yachi, sunshine is more reputable brand? Gimme flames anytime anyday ! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 1:22am On Feb 05, 2018 |
Ijeoma660: Yeah.
6nos. 2S3P. Seriously considering going back to 6P. So the system voltage operates at 35- 41v which makes it even cooler.
The more heat it dissipates from the cooling fins the more losses and faster degrading of electronic components. 6 Parallels? Way too much current = worse losses |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 1:22am On Feb 05, 2018 |
a series of DIYs coming up soon . . . |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 11:59pm On Feb 04, 2018 |
SolnergyPower: @Makavele, your comment below to DMerciful was rude. Please apologize to him. He does not deserve your insult. DMerciful , I am sorry & I take back the insult. |
Autos › Re: Camry facelift Upgrade To The New Lit Lexus face� by makavele: 1:52am On Feb 04, 2018 |
Rice |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 1:20am On Feb 04, 2018 |
Call/watapp 08117398294 or email Info@monzpowersolutions.com
You can also like our page on facebook.com/monzpowersolutions for beautiful installation pictures. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 1:20am On Feb 04, 2018 |
Inverters Felicity 3.5kva/24v( 35amps charging current) - 165k 5kva/48v ( 30amps charging current) - 185k 7.5kva 48v (40amps charging current) - 340k 10kva 48v- 395k |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 1:19am On Feb 04, 2018 |
Other products in stock includes luminous, genus, monbat, toplight etc |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 1:19am On Feb 04, 2018 |
Batteries (200ah) Quanta - 130k Long - 115k Other products in stock includes luminous, genus, monbat, toplight etc |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 1:18am On Feb 04, 2018 |
DMerciful: Told you this guy from romancelander is trying to be popular.... You can all see he is trying to mess up this thread.... Ignore this guy and he falls into oblivion Will you keep kwayet ? |
|
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 11:22pm On Feb 03, 2018 |
You can also like our page on facebook.com/monzpowersolutions for beautiful installation pictures. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 11:21pm On Feb 03, 2018 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by makavele: 11:20pm On Feb 03, 2018 |
You can also like our page on facebook.com/monzpowersolutions for beautiful installation pictures. |