| Re: Solar Energy, A Complement To FTA by ojeysky(m): 4:47pm On Jul 20, 2020 |
pcoolioz:So long as your CC is able to stop charging when your battery is full. Normally lead acid are better charged at .1C so if your solar is charging at that rate or a little bit higher, you should be fine. |
| Re: Solar Energy, A Complement To FTA by generationz(f): 4:52pm On Jul 20, 2020 |
I don't know where else to ask so I'll put it here. Does anyone know how much Busbar is for PHCN meter? |
| Re: Solar Energy, A Complement To FTA by mctfopt: 6:47pm On Jul 20, 2020 |
dapsyra:What system voltage are you running? |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 6:58pm On Jul 20, 2020 |
dapsyra:WOw..... I'm sure the shipping was crazy right? Can i see pix of your battery bank? |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 7:01pm On Jul 20, 2020 |
mctfopt:I think he is in 48v |
| Re: Solar Energy, A Complement To FTA by mctfopt: 8:00pm On Jul 20, 2020 |
Trippledots:Cool. The LTO looks so good when connected ![]()
|
| Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:31pm On Jul 20, 2020 |
20,000 cycles!!! I am green with envy ![]() Makes PylonTech look like a joke - I remember our back end conversations back then around the Tesla PowerWall - it was you that convinced me this Lithium thingy was viable in a residential use case. I was lucky to get a few Lithium installs under my belt shortly after and no looking back since that time. One day when I grow up, I will be able to afford a premium LTO bank. Hopefully, I will still have a few internal organs left to sell in exchange. My Oga Dapsyra, well done! dapsyra: |
| Re: Solar Energy, A Complement To FTA by ojeysky(m): 8:44pm On Jul 20, 2020 |
mctfopt:O'boy see the bus bars on those cells....chai! |
| Re: Solar Energy, A Complement To FTA by mctfopt: 9:21pm On Jul 20, 2020 |
ojeysky:So you can do a 5C discharge in peace ![]() |
| Re: Solar Energy, A Complement To FTA by essegis(m): 9:30pm On Jul 20, 2020 |
dapsyra:Hmmmm. I really didn't consider LTO when setting up my systems. With this your write its something to look up and possibly consider in the nearest future. Though in my research into Lithium I no see them praising it the way you praised unending here oo. But who am I? Anyway, enjoy your batteries abeg. |
| Re: Solar Energy, A Complement To FTA by ojeysky(m): 9:45pm On Jul 20, 2020 |
mctfopt:My BMS won't even permit that. This is probably for heavy duty work/factory I don't think a household would need this much. For instance, how will one even pull 5C from a 24v inverter connected to a 200AH LTO/LFP. Most inverter will throw overload before it gets to 3C (and for 48v the Current pull will even be lower). I think it's an overkill jare |
| Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 9:55pm On Jul 20, 2020 |
And why would anyone want to do 5C discharge in any stable application? Call me old school or a scared old man but I use my own PylonTechs much like lead acid. Set 80% DoD cutoff on the inverter but rarely do more than 60-70% DoD because the bank is sized for some autonomy. Only once has the BMS ever cut off or raised an alarm in like 8 months of use and that was in the early days when I was still hunting for the right settings and sweet spot. I feel such gentle use guarantees the trouble free enjoyment of ones investment for the long term. mctfopt: |
| Re: Solar Energy, A Complement To FTA by dapsyra(m): 10:15pm On Jul 20, 2020 |
mctfopt:I run 52.8v norminal (2.4v per cell, 22s) |
| Re: Solar Energy, A Complement To FTA by dapsyra(m): 10:36pm On Jul 20, 2020 |
Trippledots:You can say that again. Shipping and Customs duty were responsible for half the cost. The battery bank is located in a very tight area of my power room, so getting good snapshots is very difficult.
|
| Re: Solar Energy, A Complement To FTA by dapsyra(m): 10:41pm On Jul 20, 2020 |
mctfopt:I have the pouch cells. They are 55Ah, 2.4v nominal each. Those cylindrical cells are about 10Ah |
| Re: Solar Energy, A Complement To FTA by dapsyra(m): 10:48pm On Jul 20, 2020 |
NiyiOmoIyunade:Niyi, those PylonTech batteries are quite good. I took a brief look at them back then before settling for the LTO cells. I had a client that ordered large quantity of LTO cells (>120kwh). I seized the opportunity of the bulk purchase to grab some cells for myself at a very affordable price. |
| Re: Solar Energy, A Complement To FTA by dapsyra(m): 11:00pm On Jul 20, 2020 |
essegis:One man's food is another man's poison. All the "PRO" points I listed cannot be faulted in any objective review. The only complaint I have seen about them that I did not list in my "CONs" list is the claim that their cycle efficiency is lower that other Lithium flavours. My personal experience with LTO is contrary to that claim maybe because I am not running them at 10C. For home solar storage, nobody need 10C. At 10C, the battery bank will be depleted in 6minutes! That will be a very poor design |
| Re: Solar Energy, A Complement To FTA by mctfopt: 5:19am On Jul 21, 2020 |
NiyiOmoIyunade:For peeps that love to walk on the wild side, that 5C is a prerequisite for having system such as these. ![]() |
| Re: Solar Energy, A Complement To FTA by mctfopt: 5:23am On Jul 21, 2020 |
dapsyra:I think the cycle efficiency is the major edge that lipo has over LTO. But all in all we cannot have it all. You win some you lose some. LTO is super cool battery. And anyone doing more than 1C in any of these batteries in a constant basis must really have a very deep pockets ![]() |
| Re: Solar Energy, A Complement To FTA by ceaser: 5:46am On Jul 21, 2020 |
mctfopt:Okay. I guess I'll try that out with the MakeSkyBlue I have around here. |
| Re: Solar Energy, A Complement To FTA by essegis(m): 7:15am On Jul 21, 2020 |
dapsyra:Yeah, I went searching last night after the post and saw the cycle efficiency default. Abeg that one no be big issue joo. Over size the bank if that's the case. Is it working? E dey bring light? E no dey die? Na wetin we dey find be that. Enjoy bro, you've given me something to think about again and I love it. |
| Re: Solar Energy, A Complement To FTA by ojeysky(m): 7:21am On Jul 21, 2020 |
dapsyra:I saw you mentioned you have 300AH of the LTO do you even do 300AH instantaneous on it? For a large bank that is 200AH and above, I still wonder why a household will need to do more than 1C. Wetin we dey power sef....na factory |
| Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:50am On Jul 21, 2020*. Modified: 3:46pm On Jul 21, 2020 |
NOW AVAILABLE FOR ORDER! Brand New Foresolar 250a 12v Battery ..... 110,000 Weight: 70kg Warranty: One year standard warranty ! Contact for enquiry & orders, Smartcell global services Call:: 081-350-31951 WHATSAPP::: https:///2348170385620
|
| Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:33am On Jul 21, 2020 |
generationz:It depends on amps needed ! Ranges from 15k upwards .. It can also be improvised ! Cheers |
| Re: Solar Energy, A Complement To FTA by dapsyra(m): 11:26am On Jul 21, 2020 |
essegis:From my personal experience running LTO batteries at very low "C" rates, the cycle efficiency is about 99.9%. For comparison, the cycle efficiency of Lead Acid battery is about 70% My bank is 700Ah and the highest instantaneous load it has ever seen is 100Ah. That is 0.14C on a battery that is capable of 10C |
| Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 12:05pm On Jul 21, 2020 |
Cost to capacity ratio was one of the biggest hurdles to me going Lithium. People could not understand why I felt I needed a 48v 800Ah Lithium bank - whenever I told friends and professionals that my measured overnight consumption could be up to 15kwh they would say impossible. And this was not counting evening use o. See below graphic at 11:25pm. 41kwh consumed before midnight on a day that solar generated 47kwh. 35% of 40kwh battery already consumed as well. dapsyra:
|
| Re: Solar Energy, A Complement To FTA by dapsyra(m): 12:29pm On Jul 21, 2020 |
NiyiOmoIyunade:Your battery bank should be designed for your need not what someone else think. I am 100% off-grid and my system is designed to meet my needs with enough redundancy to cater for 2 days of bad weather. |
| Re: Solar Energy, A Complement To FTA by ojeysky(m): 12:51pm On Jul 21, 2020 |
dapsyra:Oh this is even massive than I thought (think I saw 300AH in one of your post). You made my point about C rates, what's the essence of a high C rate then.... paying for high C rate in such scenario will be unnecessary |
| Re: Solar Energy, A Complement To FTA by essegis(m): 1:13pm On Jul 21, 2020 |
NiyiOmoIyunade:Man, the consumption here is off the chart. Probably you put everything into one system. Remember that my design? Once I did all the plus and minus and balanced it as I can the battery never leaves float oo, & na ordinary 15kwh. To the extent my CC no dey gree overwork the panels to charge am. Thats why I no dey post solar panel draw like Ojeysky here oo dey shout panel power. Me sef is shaming of my system ![]() |
| Re: Solar Energy, A Complement To FTA by generationz(f): 1:16pm On Jul 21, 2020 |
kiekie1:How do we calculate the also needed? |