Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by Muyi002(m): 10:07am On Sep 13, 2020 |
Oga Topsy23, Well done. Please I need your enlightenment on the requirements as it relates to wire cables for a 4 bedroom apartment and the kind of DB to use. Please assist with the requirement. My plan is attached. I dont mind if you can add the current prices of the wires
|
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 12:12pm On Sep 13, 2020 |
Muyi002: Ok. Do you plan to ins inverter or solar so that I will factor it to the quote. And also number of AC and water heater . Thanks |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by Muyi002(m): 1:09pm On Sep 13, 2020 |
topsy23: Please I am not intending to do inverter or Solar. Water heater - 2 Proposed A/C is 1 You can put the addition wires for inverter separately. You never can tell what the future holds. |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 1:50pm On Sep 14, 2020 |
Muyi002: Thanks for visiting this thread |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by Muyi002(m): 2:51pm On Sep 14, 2020 |
topsy23: Thank you more. |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 9:27am On Oct 03, 2020 |
Muyi002: You are welcome |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 10:44am On Oct 04, 2020 |
Good morning |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 3:55pm On Oct 07, 2020 |
We are second to none when it comes to neat and well arranged pipe installation
|
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 11:38pm On Oct 09, 2020 |
Happy customers week |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by Nobody: 12:50am On Oct 10, 2020 |
COMFORTER CLEANING SERVICES WE CAN MAKE YOUR HOME OR OFFICE SPARKLING CLEAN... Comforter Cleaning Service is a Cleaning Company that has provided first class cleaning services within and outside Lagos. Our services include Pre & Post Construction Cleaning, Rug Washing, Janitorial Cleaning Fumigation, Service Floor Restoration and Polishing Service Facility Management Service Carpet Cleaning services And Facilities Management Services including Repairs Gardening Painting etc. Our watch words are Professionalism, Integrity, and dexterity.
|
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 10:04pm On Oct 10, 2020 |
Check out our final sub-circuit termination You will only get neat and best from us 1 Like
|
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by rajput4real93: 7:19am On Oct 12, 2020 |
Good morning oga topsy. Please can an electrical appliance with 220-230V work in Nigeria? |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 8:43am On Oct 12, 2020 |
rajput4real93: Yes sir it will work perfectly. Our voltage is between 220-240V. and our frequency is 50Hz |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by rajput4real93: 9:16am On Oct 12, 2020 |
topsy23:Thanks very much sir. |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 10:01am On Oct 12, 2020 |
rajput4real93:You are welcome boss |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 4:17pm On Oct 15, 2020 |
Recently terminated DB
|
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 2:20am On Oct 17, 2020 |
Nice weekend ahead |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 9:29pm On Oct 17, 2020 |
Call us today |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 12:15am On Oct 22, 2020 |
Thanks for your calls |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by sewenswepzy(m): 12:04pm On Oct 22, 2020 |
Can someome give an estimate of wiring this property..like quantity of wires and estimated price of wires that will be needed. U can drop a contact number too. Thanks.
|
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 1:16pm On Oct 22, 2020 |
sewenswepzy: It will be a bit difficult to determine/generate the quantity of cable needed for this building without the floor plan. Send us a floor plan to get the estimated quantities and cost. You can as well go through our thread for more information. Cables https://www.nairaland.com/2326721/nigerchin-kabelmetal-coleman-cables/23 |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 9:12pm On Oct 25, 2020 |
Let's handle your Electrical, Plumbing and AC |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by Cadamatics: 12:12am On Nov 01, 2020 |
Hello topsy23, I'm at MEP stage of a family build and my electrician is recommending a mixture of 1.0mm2 and 1.5mm2 cable for lights. No problem for 1.5mm2 but unsure about 1.0mm2. My question is: is he right and do you use 1.0mm2 for lights on domestic building? His reason is that modern electric light bulbs are becoming more energy-efficient (aka LED) and hence low power consumption. Grateful for your advice. Thanks ~Cadamatics |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 10:16am On Nov 01, 2020 |
Cadamatics: Happy Sunday Sir, 1mm can be use only if the number light will not exceed the amperage rating of the 1mm. The reasons for 1.5mm is to have rest of mind when the installation is completed and handover to the client . The IEE regulations says 1.mm is for lighting, 2.5mm for sockets, 4mm is for AC and water heater and 6mm for cooker unit. The current rating of 1mm must not exceed 14A while on 1.5mm 19A. If the 1mm is Nigeria cable he can go ahead. Most of the imported cables are not up to the size written on the body. Am available more clarification. Thanks 2 Likes 1 Share |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by Cadamatics: 8:25pm On Nov 01, 2020 |
topsy23: Thank you for your quick response - really appreciate it. He's recommending Cometstar cables, which I understand are Nigerian made cables. |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 5:57am On Nov 02, 2020 |
Cadamatics: Cometstar, Coleman, nigerchin and kabelmetal are all Nigeria cables Call us today 1 Like |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 9:01am On Nov 02, 2020 |
Cadamatics: You can as well check our thread on cables: https://www.nairaland.com/2326721/nigerchin-kabelmetal-coleman-cables/26 |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 12:55pm On Nov 04, 2020 |
Nice day ahead |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 9:22am On Nov 07, 2020 |
Call us today |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by akinola98: 9:32pm On Nov 07, 2020 |
topsy23: I really like ur works Always neatly arranged I have bookmarked u for my next project soon in Jesus name Keep on the good works 1 Like |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23: 8:38am On Nov 08, 2020 |
akinola98: Thank you sir, I really appreciate your comment We believe in standard operating procedure and and we do things right .. Thank you once again sir |
Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by Omonjoe(m): 3:27pm On Nov 08, 2020 |
@topsy23, check your email |
(1) (2) (3) ... (25) (26) (27) (28) (29) (30) (31) ... (45) (Reply)
₦500 Million Lagos House Causes A Stir Online / Apartment For Rent Lagos Nigeria - Flats For Rent Lagos / Ask All Your Questions On Building Foundations/structural Issues -expert
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 29 |