COMMUN_FAIL And BD_STATUS Alarms Reported On Main And Extended Subrack by zoeduan: 9:10am On Dec 26, 2017 |
COMMUN_FAIL and BD_STATUS alarms reported on main and extended subrack due to a locked AUX board. Issue Description: Over an Huawei OSN 3500 that have extended subrack, Alarms of BD_STATUS appear over the boards(PQ1, XCE, PIU and FAN) of the extended subrack, and COMMUN_FAIL(SXCSB, SL64,EFS0,EGS4,SLQ16) over the main. Root Cause: In cases like this, the most probable cause of this problem is the Huawei AUX board. It was necessary to check if was the AUX of the main or the Extended Subrack.The AUX board is take as the main point of failure in this case because it realizes communication between boards in the subrack. |
(1) (Reply)
Dell Latitude E6430 Review / Here Is The Truth Untold About Making Money Online / Trending / Newest Topics
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 7 |