Iinnov8's Posts
Nairaland Forum › Iinnov8's Profile › Iinnov8's Posts
1 2 3 4 5 6 7 8 9 10 11 12 (of 20 pages)
bonetalk:Hello bro, Thanks for the enquiry. I am not always online. The 1600w is not readily available, but i have 1 unit left. The 3000w is 103k now |
seunlayi:Lol...pleasant to hear, bro. What is the size of your pumping machine? The good thing about the inverter is, even if you overload it more the capacity, it will simply trip off on overload, and you just have to switch it off, take off the load the load and switch it back on and it will resume working as if nothing happened |
CaptainZubi:Your existing controller is NOT an MPPT controller. It is PWM, plastered with MPPT signage. So there is no basis for comparison for both of them. |
60A PowMr MPPT Solar Charge Controller Price: 91,000 firm
|
60A PowMr MPPT Solar Charge Controller Price: 97,000 firm
|
60A PowMr MPPT Solar Charge Controller Price: 97,000 firm CaptainZubi, consider this. If you are in Lagos, you can get it today
|
60A PowMr MPPT Solar Charge Controller Price: 97,000 firm
|
Drgreatone:The price would be same with the 12v and 24v variants. Currently 102k |
adrusa:At the moment, no. But it is a possible consideration for the future |
As the rains fall in torrents and your inverter stands the risk of being affected by lightening strikes, don't forget that we got you covered with our 3000w Pure Sinewave EASun inverter. Firstly, we have the parts readily available and a dedicated technician for its repairs. We have successfully fixed over 20 units with Zero returns and with the repaired inverter carrying same load it used to carry! Secondly, we have recently introduced a Swap Programme where you will get your damaged inverter swapped with a working inverter immediately. This will eliminate the downtime you would have suffer if you had to wait to get your inverter repaired. Terms and Conditions apply Below video shows the load the inverter can carry and you can follow this thread to see reviews and video testimonials from customers https://www.nairaland.com/7833852/3000w-easun-pure-sine-wave#125672064 https://www.youtube.com/watch?v=7YgbL4Lw_Bw
|
As the rains fall in torrents and your inverter stands the risk of being affected by lightening strikes, don't forget that we got you covered with our 3000w Pure Sinewave EASun inverter. Firstly, we have the parts readily available and a dedicated technician for its repairs. We have successfully fixed over 20 units with Zero returns and with the repaired inverter carrying same load it used to carry! Secondly, we have recently introduced a Swap Programme where you will get your damaged inverter swapped with a working inverter immediately. This will eliminate the downtime you would have suffer if you had to wait to get your inverter repaired. Terms and Conditions apply Below video shows the load the inverter can carry and you can follow this thread to see reviews and video testimonials from customers https://www.nairaland.com/7833852/3000w-easun-pure-sine-wave#125672064 https://www.youtube.com/watch?v=7YgbL4Lw_Bw
|
dbelovd:OK bro |
Open box, but brand new, 60A Powmr MPPT HHJ-Pro Solar Charge Controller. Price: 98,000
|
Open box, but brand new, 60A Powmr PWM solar charge controller Price: 25,000 firm
|
Anyone0455:First mistake: it is not best practice to mix up lead acid batteries of different brands or even different age together. Also, I see that you already made up your mind to get the 2.5kva inverter and/or hybrid inverter. It is good, but I must say that you are setting your up further. You need to first troubleshoot to know the health of each of your batteries, because if they are already dying, 2.5kva or hybrid inverter will not save you. Also, most 2.5kva inverters would come in 24v and you are on 12v connection. Doing a 24v connection with your 2 batteries may worsen your situation as 24v on lead acid batteries are known to experience drifting Your fastest troubleshooting/solution is to get an external charger. Come get my 20A 12v charger for 49k. I will throw in a free DC voltage meter for you. Connect the meter to each battery and charge it separately till it gets to 14.4v. Then connect each separate battery to a load that you will take note of to see how the battery voltage drops and how much backup time you will get from each battery from that load. This will help you know whether any battery is failing and how much backup time you should expect to get when you combine both again
|
Anyone0455:First off, what you have is 0.9kva or 900va inverter, not 900kva like you stated. Secondly, if your inverter batteries are draining that fast already, getting an inverter as large as 2.5kva will make it worse as the inverter will consume significant energy to power itself - it could be as much as 40w Finally, your batteries may not be bad per se. You may just have an under-charging problem. Inverters with charging function do not charge batteries optimally. Most times, they undercharge your batteries. Your lead acid batteries should bulk charge to 14.4-14.6v (full charge), then float down to 13.6v if left idle. But most inverters will charge to 13.5v, then stop charging and indicate as battery full when the battery isnt. The result is this sharp drop in voltage you currently experience and you wont get good backup time from the batteries. And if this situation continues, the batteries will begin to experience sulphation on the plates, leading to more damage. What you need is an external charge to continue charging the batteries after the inverter stops its own charging. Also use a multimeter to get the voltage readings of your batteries while at it. Meanwhile, where is your location? How many batteries do you have? And in what way are they connected - 12v or 24v? |
Guys, is any of us who is an installer around this location. I need the person for a prospective installation The Lord's Chosen Church, Rukpokwu Town, PH, off International Airport Road |
Omoapena:Your comment, which I emboldened, is very funny. It is easy to see why you are easily picked as an object of ridicule here. I understand English, bros, and I speak out of direct experience and as a direct user, so I have earned the right for you to listen to me in matters relating to CNG usage - CNG is NOT easy or cheap to convert. Only Nipco provides a subsidised conversion rate. The last time i checked, it will cost you nearly 1m to convert a 5cylinder vehicle, with months of painful delays and back and forths. Then it will cost you an extra 300 - 500k to do the conversion in other centres. How many people can easily dole out that sum? - Rate of gas consumption is dependent on the number of cylinder your vehicle has (just like fuel) and the pressure of the dispensing Point at the time. The more cylinders you have and if the pressure is low at the time you bought the gas, then you will find yourself going to thr gas station more often. - The moment you port to gas, mechanics will be scared of touching your vehicle because of all the connections and contraptions of the gas kit at your engine area and boot. And if your vehicle has an issue, you will keep wondering whether it is the gas installation or something else that is the source of the problem. Of course, your first port of call will be the engineers who did the installation, but they will simply tell you to bring it for re-calibration, and they will plug in their laptop to re-calibrate, then refer you to your mechanic, who will then refer you back to them and you will keep going back and forth - Parts availability is inconsequential here. You will always depend on the conversion centre for any gas-related parts |
Omoapena:I have been using CNG since last November and I can categorically tell you that all 4 points you mentioned in your post are wrong. I am still observing the thing and I will provide a detailed expose on my experience in 2 months time. |
jonescosmos:100meters in a roll |
Dam5reey1:Resident Chief Whip of the thread and Lover of violence... ...I greet you. Thanks for your patronage of my cables. Much appreciated.The sharp practices in cable sales from most sellers inspired my introduction of these cables. It is bad enough that we are buying 6mm2 cables for 4k per meter that is not measured correctly. It is even more terrible that people are sold 4-5mm2 as 6mm2. Innocent buyers make double loss One of my major emphasis to suppliers during my sourcing was the assurance of full and complete 6mm2 of 84 strands, and I got loads of samples to confirm so before deciding. I believe in giving customers the full value of what they pay for. They deserve it. The extra value I provide will then inform their decision of whether to buy from me or the next person. |
Dam5reey1:Hahahahaha...you sef see am...lol |
jonescosmos:Ah! My oga, we still dey do in meters and rolls for now o...lol...but soon, very soon... ![]() |
Allem:My chairman! Thanks baba... ![]() |
Penuelseun:Thanks boss. Much appreciated |
ManAdii:Waybill can be done [Quote] Genuine 6mm2 (10AWG) 2-in-one solar cable with free pair of 30A 1500V MC4 connector Price: 3,750 per genuine meter - TUV-approved real 6mm2 containing exactly 84 (counted) strands of tinned copper. Tinned copper does not rust, turn green or cut off over time due to adverse weather conditions - Two-layered (black and red) cable sheaths that is thick and treated with irradiation to ensure it doesn't crack, giving you at least 25years of usage - Cables can be split easily along its spine for more application, manipulation and manoeuvring - Cables will come in genuine measurement of meters. There are numerical markings after each meter measurement, and cables will be cut just in front of this numerical marking to give an exact measurement for each meter - Minimum order quantity is 15 meters and you will get a free gift of 1500v 30A MC4 connector for every 15 meters you buy Call/Whatsapp: 091-6043-7395 https://www.youtube.com/watch?v=73cZR6BdCmM?feature=shared[/quote] |
FashionCapital:I love that you did your price survey. My price is over 100naira cheaper than Jumia's. But it is beyond the price Jumia will not provide you with after sales support or remote assistance during installation. Someone bought a controller from me on Friday. He called yesterday morning and complained that the controller wasn't coming on after connecting the battery. We immediately switched to Whatsapp video call, did some remote troubleshooting and discovered that the voltage of his battery was 9.2v or so, which was too low to get the controller started. I advised him to charge up his battery up to 10.5v and update me. He did and sent me the attached screenshot confirming that controller is now working. You won't get such support from Jumia. Also, if you have any issue 7days after purchase from Jumia, you are completely on your own. As to your questions, yes it is new and supports voltage range from 12v to 48v. This is the first controller model from Powmr and it has seen series of software updates. There are other more expensive models, but this one still gets the job done and is ideal for people on a budget
|
60A PowMr MPPT Solar Charge Controller Price: 91,500
|
seunlayi:Much appreciation for the patronage, boss. Bless us with videos and pics too... ![]() |
60A PowMr MPPT Solar Charge Controller Price: 91,500
|
60A PowMr MPPT Solar Charge Controller Price: 91,500
|
. Behold, it worked, I checked the inverter, no sign of danger, I pumped water sufficient for the night with my 24v Easun inverter.