Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / NewStats: 3,153,060 members, 7,818,177 topics. Date: Sunday, 05 May 2024 at 09:30 AM |
Nairaland Forum / Nairaland / General / Properties / EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? (30129 Views)
ELECTRICAL(CONDUIT&FITTINGS),CCTV, AUDIO SYSTEM, VIDEO DOORBELL & ELECTRIC FENCE / Electrical Piping Both Surface And Conduit / Marlians Not Allowed In My House, Landlord Issues Warning To Tenants - More (2) (3) (4)
(1) (2) (3) (4) (5) (Reply) (Go Down)
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by zeyt: 7:49pm On Aug 15, 2023 |
The team suspected that you tapped wire from inside the building before it comes out of the building. Simply put the team is suspicious of meter bypass in the premises which is serious offence under the company law. 4 Likes 1 Share |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by saintneo(m): 7:49pm On Aug 15, 2023 |
There is a possibility that a bypass of the prepaid meter could be hidden within the concrete. Nevertheless, I am surprised that a prepaid meter is installed inside the house. It makes no sense to have a PPM inside because it can be tampered. Regarding the conductors, if they are actually conduit, the it can simply be pulled out without damaging the building. 13 Likes 3 Shares |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by kenchop: 7:50pm On Aug 15, 2023 |
SUE THEM TO COURT. THEY CANNOT DEMAND YOU DAMAGE YOUR STRUCTURE WITHOUT GOOD REASON AND ALSO WHO BARES THE COST. NIGERIANS ARE TOO TOLERANT THATS WHY NONSENSE KEEPS HAPPENING. 1 Like |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Jsucre(m): 7:50pm On Aug 15, 2023 |
Oga bring out the wire, or else I go cut your light via nairaland. |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by egbedox: 7:50pm On Aug 15, 2023 |
MilesLamar: You have just said the obvious. Some customers divert loads before it gets to meter. What they are asking for in essence is to see how your wires coming from pole entered the meter. 4 Likes |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by TarantinoEl: 7:50pm On Aug 15, 2023 |
Na so the thing go ! |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by jojothaiv(m): 7:51pm On Aug 15, 2023 |
slowice:π³π¬ |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Starboytwo(m): 7:51pm On Aug 15, 2023 |
DenreleDave:itβs our way. 1 Like 1 Share |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by akpumping7720(m): 7:51pm On Aug 15, 2023 |
Them dey fear bypassing of wires. |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Fixed: 7:52pm On Aug 15, 2023 |
Because you can easily tap light for free from the part where the wires are hidden. That is what is called bypassing of meter. 1 Like 1 Share |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by BoldBrainz(m): 7:54pm On Aug 15, 2023 |
Visit their nearest service center and get proper details. And you don't need to tamper with the structural integrity of your home to extricate conduit wires. Things like this are part of the essence of a man-hole in the house. 1 Like |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Torpman(m): 7:55pm On Aug 15, 2023 |
I work with EKEDC as an enumerator, the reason why you were given that disconnection order is because of the common practices of some customers bypassing their meter through those medium. It's very easy for a customer to tap from the wires in the condict without anyone knowing 4 Likes 1 Share |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by nextstep(m): 7:57pm On Aug 15, 2023 |
The wiring should not have been conduited right into the building. You typically would have junction box outside the wall, and the mains lines would go into that junction box or meter. This ensures that all the electricity to the building can be disconnected from one place (either for billing or for fire/electrical safety). As it is, there is no (visual) guarantee that the mains wires are not split in a way that bypasses the meter or mains switch. Again, you want an easily-verifiable way to show that the house is not energized. Advice would be to do what NEPA has asked: cut the mains, reroute first to a meter, then connect from meter back into the conduit. But I'm sure since I'm talking to a fellow Nigerian blessed with oversabi and shortcut, a few 10k will settle the matter with NEPA and the problem will not be fixed - just ignored... for now. 6 Likes |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by eneyoduke(m): 7:58pm On Aug 15, 2023 |
It's part of measure to reduce energy theft, A service wire passing through a wall before entering the prepaid meter shown that alot of things are happening behind the scenes, in order to avoid disconnection you have to do the right thing immediately to avoid sanctions. A cable passing through a building wall before reaching the the electricity meter is a form of Energy theft due to a lot of experience. 4 Likes |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Chetas81(m): 8:01pm On Aug 15, 2023 |
Fraudulent citizen inside Nigeria decided not to change π¦ |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by otoworostephen(m): 8:02pm On Aug 15, 2023 |
They're very right on this and it is not applicable to only EKDC but all meter users anywhere... The fear is that meter can easily be bypassed. Meanwhile, what dey don't know is that professional Electricians like myself can successfully bypass the meter be it outside or inside... Contact me for your general electrical works and meter installation otoworostephen@gmail.com Meanwhile, same people when nor dey pay nepa bill dey talk here dey insult me. When Nepa show you Shege you go understand this country.. my last bill for my house in Edo state was 40k all in the name of estimated billing, for house when I no stay pass 5days before I lock everywhere return to Lagos... Una go explain tire, no evidence... |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Babamide(m): 8:03pm On Aug 15, 2023 |
Electricity distribution company no get sense. Meters on the pole are in use for this kind of conduit wiring. Simple ask that your meter be changed to a Pole meter to avoid stress if you don't have anything to hide 6 Likes |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Z43cvahi: 8:04pm On Aug 15, 2023 |
Scam this white heads, Pray! Bomb! Keep Bombing, Cashout!, Repeat the process!!, Thank me later & I got you.. Dollar is hitting 1k soon... Remember that Tinubu didn't promise you nothing, he only said "IT IS HIS TURN"
|
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Ofemini(m): 8:05pm On Aug 15, 2023 |
[quote author=ai9090 post=125135142]Yes it doesn't I want to sell my LG Side By Side GC-B207WVQ Refrigerator[/quote Pic, condition and location |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Bbbwings: 8:06pm On Aug 15, 2023 |
molas02: |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by breezeng: 8:07pm On Aug 15, 2023 |
Probably you have bypassed the meter. You just need to run a surface cable that everyone can see from energy source to your meter. You don't need to brake the wall. Just run new cable and disconnect the conduit line.That is the way you can convince them. You have to follow the rule, else you will be disconnect ed or even surchaged if you are not careful. 1 Like |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by TheMaharajah: 8:07pm On Aug 15, 2023 |
No need to break anything. Cut the wire from the entrance of the conduit and the exit outside the conduit pullout the hidden wires and rejoin the visible exposed wires. There you have it. |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by nextstep(m): 8:09pm On Aug 15, 2023 |
otoworostephen: Wait, what? Did you really mean to type bypass? In a thread against bypass? My country people sef... 5 Likes 1 Share |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by mokset123: 8:11pm On Aug 15, 2023 |
It's their new policy got same from BEDC about a year plus ago and I complied. I also know someone from AEDC zone who got same too. This is to forestall meter bypass |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by immortalmortal: 8:12pm On Aug 15, 2023 |
Bring out the wires from conduit |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by ai9090: 8:16pm On Aug 15, 2023 |
[quote author=Ofemini post=125135466][/quote] Can you message me on Whatsapp.. 0 8 1 4 9 2 0 4 4 2 1 |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by baconline(m): 8:18pm On Aug 15, 2023 |
Conduct wiring should only be done after the meter not b4,I support thos 100 percent 1 Like |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Nasir123(m): 8:18pm On Aug 15, 2023 |
You do not need to brake the wall. If the wire is stuck then you have to cut it and add another cable to run it in surface to the DB. I believe the reason for d order is for them to be able to view the directions of the cables that supplies the building. |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by slimmoney(m): 8:21pm On Aug 15, 2023 |
Service wire is not supposed to be conduit. 1 Like |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by Kabba1977(m): 8:21pm On Aug 15, 2023 |
I beg if you can beat them woto woto |
Re: EKEDC Issued A Warning To Bring Out Wires From Conduit - Any Advice? by President2001(m): 8:22pm On Aug 15, 2023 |
Is because of tampering |
Cocoa House : Tropical Africa's First Skyscraper / PHOTOS: Gov. Ganduje Sells 2 Bedroom Houses For N2.7 Million In Kano / Bitter Experience Of A Landlord Whose Tenants Refused To Pay 3 Yrs Rent Or Quit
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 30 |