Solar Energy, A Complement To FTA - Satellite TV Technology (218) - Nairaland
Nairaland Forum › Entertainment › TV/Movies › Satellite TV Technology › Solar Energy, A Complement To FTA (3417425 Views)
1 2 3 ... 215 216 217 218 219 220 221 ... 2397 Reply (Go Down)
| Re: Solar Energy, A Complement To FTA by DMerciful(m): 9:11pm On Mar 03, 2017 |
http://encell.com/fused-iron-batteries/ http://beyondoilsolar.com/product/nickel-iron-battery-encell-usa-series/ Trippledots: |
| Re: Solar Energy, A Complement To FTA by DMerciful(m): 9:15pm On Mar 03, 2017 |
Those batteries are being forced to give their all......they are likely to fail sooner than later chris81964: |
| Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:55pm On Mar 03, 2017 |
DMerciful:Not totally maintenance free ! I admire the 80% DOD advantages and I also hope Chinese brands or imitations won't flood the open market on the short run tho ..
|
| Re: Solar Energy, A Complement To FTA by bigrovar(m): 6:51am On Mar 04, 2017 |
Saipro:If only nairaland has support for stickies.. This post should be tucked right where everyone can see them. Our Trojans spent a wee too long in the warehouse. We have no idea of how they were maintained or bulk charged (3 of mine came with swollen terminals and buckled plates).I think you are on to something there |
| Re: Solar Energy, A Complement To FTA by chris81964(m): 8:35am On Mar 04, 2017*. Modified: 11:39am On Mar 04, 2017 |
DMerciful:The experience I have is similar to the experience many off grid people have. The cure is exactly what I am doing. So if you have a different solution I would like to hear them. My batteries will soon be 3 years old (sorry for the typo) and I am having the same results now as I did at the beginning. Off grid folks get ten years from the L16 doing what I am doing. Sorry for the error |
| Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:50am On Mar 04, 2017 |
Oga Chris.....10yrs old? Twale for you....you must be doing the right thing. Pardon me, I say twale again. ![]() chris81964: |
| Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:51am On Mar 04, 2017 |
We are talking about 40yrs life span.....nothing beats that! kiekie1: |
| Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:07am On Mar 04, 2017 |
DMerciful:When yours arrive , talk from your personal usage experience .. I stated few clear points above and didnt ridicule lifespan of battery as said by its manufacturer , although any lil malicious damage-clause can affect warranty validity in Nigeria ! |
| Re: Solar Energy, A Complement To FTA by DMerciful(m): 9:19am On Mar 04, 2017 |
I did not order Nickel iron(too expensive) but LiFeO4. Check reviews online and other research.....they are almost incomparable apart from frequent watering which the latest models have addressed by installing auto watering system. Nickel iron batteries like iron Edison are mostly used by power companies! kiekie1: |
| Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:08am On Mar 04, 2017*. Modified: 11:01am On Mar 04, 2017 |
DMerciful:My dear friend I ain't arguing with you on this as theory aint practical OK !! As per longetivity, like Chris mentioned about his batteries hitting 10yrs , have u seen tubular/flooded hoppecke or IND Trojans die prematurely especially when not abused cos they ain't totally maintenance free ?? When companies in Nigeria brings in "Nickel iron & LifeP" after much experiments & abuse within , doubting Thomases will believe more in the said product k |
| Re: Solar Energy, A Complement To FTA by chris81964(m): 11:40am On Mar 04, 2017 |
DMerciful:Sorry three years. MAJOR TYPO. |
| Re: Solar Energy, A Complement To FTA by chris81964(m): 11:41am On Mar 04, 2017 |
kiekie1:No vex not 10 three years |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 2:01pm On Mar 04, 2017 |
| Re: Solar Energy, A Complement To FTA by harveyspec: 8:01pm On Mar 04, 2017 |
please if an inverter is rated 1700va, 1190W with a crest factor of 1:5 what does it mean? cc: chris81964 DMerciful bigrovar |
| Re: Solar Energy, A Complement To FTA by DUNKA(m): 6:08am On Mar 05, 2017 |
chris81964:Oga Chris Goodmorning watched your YouTube videos and needed clarification on the issue if Generator set when offgrid. If one has sufficient panels will one still need a gen set? Abi had large array so why would he still a genset since he is in imploring and sunlight is not a problem? It seems the Trojans are not what they used to be or we have a specific problem with those been supplied. Have you been able to recover the faulty cell you tried rejuvenating? Is the US battery in your bank ever had the same issue that you are experiencing with the Trojans ? Thanks for your response. |
| Re: Solar Energy, A Complement To FTA by abunafiu(m): 8:08am On Mar 05, 2017 |
DUNKA:You have a point. |
| Re: Solar Energy, A Complement To FTA by DMerciful(m): 9:45am On Mar 05, 2017 |
I don't have appreciable knowledge on crest factor..sorry harveyspec: |
| Re: Solar Energy, A Complement To FTA by bigrovar(m): 11:28am On Mar 05, 2017 |
harveyspec:1700va and 1190w just means the inverter has a power factor of about 0.7 (The difference between VA and W is represented by power factor. VA is used with AC appliance were sometimes volt and amps go out of phase this is caused by how AC appliance load shifts the phase of the current compared to the phase of the voltage. The closer the power factor of a device is to 1 the more efficient that device is at power consumption. hence 0.9 PF is better than 0.8. You can get the PF of a device by dividing w by va in your case 1190 / 1700. Crest factor is another term for surge capability of an inverter. 1.5 means the inverter can surge up to 5 times its rated power. In this case your inverter is 1190w (its rated power) but it can surge up to 1190 x 5. Inverter makers often exaggerate their crest factor. even if an inverter can do 5 times its rated power (highly improbable) it often can only do this for about a second which might not be enough to start devices where such power is needed. Crest factor allows an inverter or generator to start devices which requires 3 to 5 times their running power when starting (usually not more than 3 secords) |
| Re: Solar Energy, A Complement To FTA by abunafiu(m): 1:39pm On Mar 05, 2017 |
bigrovar:I hereby award you a PhD. On behalf of all senior members in the house, congratulations. |
| Re: Solar Energy, A Complement To FTA by dapsyra(m): 3:59pm On Mar 05, 2017 |
bigrovar:The Crest factor of a sinusoidal current waveform is 1.414. An Inverter with crest factor of 1.5 cannot handle 5 times its rated power. It can only handle 1.06 (1.5/1.414) times its rated power for a very short period specified by the manufacturer in the datasheet. |
| Re: Solar Energy, A Complement To FTA by chris81964(m): 4:42pm On Mar 05, 2017 |
harveyspec:Crest factor of 1.5 is the amount by which it can surge. 1190 x 1.5. |
| Re: Solar Energy, A Complement To FTA by chris81964(m): 4:49pm On Mar 05, 2017 |
DUNKA:Good day. In the United States where I live they recommend that you have a generator when you are off grid. If you maintain a normal life style there are times in the year where the sun is not sufficient. For me November to February and again during the rainy season. You will break out the generator once every two weeks. The cell has started to come back. I will or have upload video two and then do video three. The US Battery is different from the Trojan. I got it 18 months ago. It uses much less water and I don't seem to experience the same problems. But then the Trojans where more abused too. |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 6:54pm On Mar 05, 2017 |
chris81964:is dat marketing job still available on your posted topics? |
| Re: Solar Energy, A Complement To FTA by bigrovar(m): 7:00pm On Mar 05, 2017 |
chris81964: dapsyra:sorry I meant 5:1 (as stated by OP) and not 1.5. 5:1 means ratio of 5 to 1. some inverter makers use 3:1, 5:1 to represent that surge factor (probably because its more user friendly) despite I doubt any inverter can do 5 times its rated output power. |
| Re: Solar Energy, A Complement To FTA by DUNKA(m): 8:07pm On Mar 05, 2017 |
chris81964:thanks for the clarification |
| Re: Solar Energy, A Complement To FTA by harveyspec: 9:31pm On Mar 05, 2017 |
bigrovar:Pls what I wrote was 1:5 not 1.5 the inverter spec sheet says it's crest factor is 1:5 (1.7kva, 1190w) my main concern is whether this inverter can power a fridge of 120w. the manual says it's not for heavy appliances & fridge was listed as one of such appliances meanwhile some folks says it can power fridges & even freezers CC chris81964 dapsyra |
| Re: Solar Energy, A Complement To FTA by dapsyra(m): 10:43pm On Mar 05, 2017 |
harveyspec:Crest Factor can be stated in decimal (x.y) or ratio (x:y). The minimum permissible crest factor is 1.0 or 1:1 which is the crest factor of DC current. The crest factor for pure AC current is 1.414 or 1.414:1 To determine the surge handling capability of an Inverter, you have to divide the stated Crest factor by 1.414 In your case, the Inverter Crest factor is stated as 5:1, so it can handle surge up to 3.5 (5/1.414) times it's capacity. The Inverter is rated 1190W, so the maximum surge it can handle is 4,165W (1190x3.5) for a very short time that would be stated in the datasheet. Your fridge is rated 120W, but the startup surge can be 3 times higher than the rated power. So, we expect a power surge of 360W. This is well within the capability of the Inverter. My conclusion: Based on the data you provided in this thread, the Inverter can power your fridge comfortably. |
| Re: Solar Energy, A Complement To FTA by bobojoshua(m): 12:14am On Mar 06, 2017 |
Saipro: |
| Re: Solar Energy, A Complement To FTA by harveyspec: 5:31am On Mar 06, 2017 |
dapsyra:thanks man, your explanation is crystal clear but it appears my elementary maths is rusty, why is everyone assuming 5:1 is same as 1:5? I thought 1:5=0.2 5:1=5 Is it that the manual made a mistake or I'm the one getting it all wrong Again the manual says 1:5 pls does your above explanation still hold? |
| Re: Solar Energy, A Complement To FTA by dapsyra(m): 8:19am On Mar 06, 2017*. Modified: 8:59am On Mar 06, 2017 |
harveyspec:Like I said earlier, the minimum permissible crest factor is 1.0 or 1:1 which is the crest factor of DC current. Crest factor cannot be lower than 1. The manual erred by stating it as 1:5. There are two ways we can try to interpret that error: 1. Take it that the manual meant 1.5. In this case, the surge factor will be 1.06 (1.5/1.414) ==> Cannot handle high surges 2. Take it that the manual meant 5:1. In this case, the surge factor will be 3.5 (5/1.414) ==> Can handle high surges Considering that it is also stated in the manual that the Inverter is not for heavy appliances, I will choose interpretation 1 above. Irrespective of whichever interpretation you choose, a 1190W Inverter will power a 120W fridge comfortably. |
| Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:09am On Mar 06, 2017*. Modified: 7:45pm On Mar 06, 2017 |
JUST OFFLOADED Yachi / YahSun Solar P-POLY,M-MONO 80w-P-25k 100w-P-30k 140w-M-42k 150w-P-43k 150w-M-45k 200w-M-60K 260w-M-75k 310w-M-85k Stocks fast running low,call & place your order today WhatsApp: O8I35O3I95I SMARTCELL GLOBAL SERVICES
|
| Re: Solar Energy, A Complement To FTA by efuro(m): 9:21am On Mar 06, 2017 |
kiekie1:Thumbs up 4 Oga Kiekie1 ![]() timely info is important keep it up! |
UPS Back-up, Also A Complement To FTA • FTA Frequency • Cctv Installation A Complement To Fta And Solar Energy • 2 • 3 • 4
Free To Air Satellite Tv General Thread