Re: Solar Energy, A Complement To FTA by ojeysky(m): 4:35am On Oct 29, 2020
Hello, has anyone used the attached diode connectors before? I want to know if it acts as current limiter if not can anyone recommend a good current limiter (preferably one that can be sourced locally)

Re: Solar Energy, A Complement To FTA by kiekie1(m): 7:18am On Oct 29, 2020
SAFETY TIP!

Tubular batteries maintenance cost is relatively high. You must buy batteries with a gallons of distilled water add cost and compare them with maintenance free battery . If you don't maintain battery on time, customer may ask refund or change under warranty time . Don't install these batteries in busy walkways area or closed non breath areas as hydrogen gas is hazardous & can cause fire .

Note: Install all flooded batteries with fireball - fire protection materials

Tubular / flooded deep cycle battery maintenance distilled water & electrolytes now available!

Distilled water 1L (12 in pack) ... 5,000
Distilled water 25L (with free gallon) ... 7,000
Electrolyte (Accurate specific gravity) ...7,000

Direct from chemical industrial plant ! Place your orders now !!


SmartcellNuggets : Once you got a solar panel on a roof, energy is free. Once we convert our entire electricity grid to green and renewable energy, cost of living goes down.

Contact,
Smartcell global services
081-350-31951
WHATSAPP::: https:///2348170385620

Re: Solar Energy, A Complement To FTA by kiekie1(m): 7:24am On Oct 29, 2020
Deka VRLA/GEl and Trojan VRLA/AGM BATTERIES!!!

DEKA 12v 210ah (VRLA GEL):
Voltage: 12V
20 HR rate : 183AH
Capacity at C/100: 210ah
Plate alloy: Lead Calcium
Container/Cover: Polypropylene
Operating Temp range: -60°C - 60°C
Vent: Self Sealing
Electrolyte: Sulfuric acid thixotropic Gel
Price:220k

TROJAN 12V 205ah (VRLA AGM):
Voltage: 12V
20 HR rate: 210ah .
Maximum Charge Current : 20% of C20
Operating Temp range: -20°C - 50°C
Material: polypropylene
Battery: VRLA/AGM/Non- Spillable/maintenance free
Price:195k

TROJAN 12V 170ah (FLOODED):
Battery Voltage: 12V
Price:118k

SmartcellNuggets: The primary means of energy generation is going to solar. It will at least be a plurality, and probably be a slight majority in the long term.  - "Elon Musk"


Contact,
Smartcell global services
081-350-31951
WHATSAPP::: https:///2348170385620

Re: Solar Energy, A Complement To FTA by Monlo(m): 8:48am On Oct 29, 2020
....

3 Likes

Re: Solar Energy, A Complement To FTA by Monlo(m): 8:55am On Oct 29, 2020
...?

2 Likes

Re: Solar Energy, A Complement To FTA by Monlo(m): 9:03am On Oct 29, 2020
More..

1 Like

Re: Solar Energy, A Complement To FTA by saint2ace(m): 10:23am On Oct 29, 2020
Monlo:
Good morning @all.
Celebrating the arrival of my newly acquired Lithium Ba3s.
Courtesy @Juo,I give him kudos for his sincerity,as I never called him in transacting this bussiness,everything was done via WhatsApp.
This goes a long way to show we still have good Nigerians doing there legitimate bussinesses online and not the opposite.Even though am still in love with my Lead acid ba3s having served me meritoriously,I will be putting them on sale......
Watch out!!!

Sun energy rules....


Congratulations bro, we go soon reach ur level....
Re: Solar Energy, A Complement To FTA by Monlo(m): 1:49pm On Oct 29, 2020
saint2ace:



Congratulations bro, we go soon reach ur level....

Thanks boss...
Nothing as sweet as free Sun energy...
Re: Solar Energy, A Complement To FTA by JUO(m): 2:15pm On Oct 29, 2020
Flex max Fangpusun
80A-12-60v=150k
60A-12-60v=125k
080-987-337-09
Re: Solar Energy, A Complement To FTA by JUO(m): 2:16pm On Oct 29, 2020
Monlo:
Good morning @all.
Celebrating the arrival of my newly acquired Lithium Ba3s.
Courtesy @Juo,I give him kudos for his sincerity,as I never called him in transacting this bussiness,everything was done via WhatsApp.
This goes a long way to show we still have good Nigerians doing there legitimate bussinesses online and not the opposite.Even though am still in love with my Lead acid ba3s having served me meritoriously,I will be putting them on sale......
Watch out!!!

Sun energy rules....
thanks for the patronage
Re: Solar Energy, A Complement To FTA by mank1234(m): 2:20pm On Oct 29, 2020
ojeysky:
Hello, has anyone used the attached diode connectors before? I want to know if it acts as current limiter if not can anyone recommend a good current limiter (preferably one that can be sourced locally)

It's not a current limiter. Allows current through only one direction. It's used to ensure that no reverse current flow through a string of solar panels.

Especially useful if you're using more than two strings, as shade in one string can result in excessive reverse current through the shaded string causing damage to that string.

2 Likes

Re: Solar Energy, A Complement To FTA by eleojo23: 2:28pm On Oct 29, 2020
Monlo:
Good morning @all.
Celebrating the arrival of my newly acquired Lithium Ba3s.
Courtesy @Juo,I give him kudos for his sincerity,as I never called him in transacting this bussiness,everything was done via WhatsApp.
This goes a long way to show we still have good Nigerians doing there legitimate bussinesses online and not the opposite.Even though am still in love with my Lead acid ba3s having served me meritoriously,I will be putting them on sale......
Watch out!!!

Sun energy rules....

Nice! What was the cost of getting these?
Re: Solar Energy, A Complement To FTA by DUNKA(m): 2:31pm On Oct 29, 2020
JUO:
thanks for the patronage
what are the specs of the batteries supplied?
Re: Solar Energy, A Complement To FTA by ojeysky(m): 3:40pm On Oct 29, 2020
mank1234:


It's not a current limiter. Allows current through only one direction. It's used to ensure that no reverse current flow through a string of solar panels.

Especially useful if you're using more than two strings, as shade in one string can result in excessive reverse current through the shaded string causing damage to that string.

Thanks, this is similar to what I read online as well, so if a current above its rating reaches it does that blow it up or is the higher current allowed to pass through?
Do you have any recommendation of a PV current limiter?
Re: Solar Energy, A Complement To FTA by mank1234(m): 3:47pm On Oct 29, 2020
ojeysky:


Thanks, this is similar to what I read online as well, so if a current above its rating reaches it does that blow it up or is the higher current allowed to pass through?
Do you have any recommendation of a PV current limiter?

If it passes current above it rating, it will eventually get damaged (through thermsl runaway). It's not meant to be a current limiter.

No, I don't know of a PV current limiter other than the functionality charge controllers provide
Re: Solar Energy, A Complement To FTA by JUO(m): 3:51pm On Oct 29, 2020
DUNKA:
what are the specs of the batteries supplied?
100ah/12v lithium battery available
Maximum charge current 50A
Maximum discharge current 50A
Maximum charge voltage 14.8v
low voltage disconnect 10v
Series connection: yes
Parallel connection: yes
over 3000 on cycle at 80% DOD
Weight 13kg
Battery has 100A bms but I choose to state 50A
Capacity is 108ah but again I choose to state 100ah

Re: Solar Energy, A Complement To FTA by JUO(m): 3:55pm On Oct 29, 2020
eleojo23:


Nice! What was the cost of getting these?
price is 170k for one, discount for 2 and above

1 Like

Re: Solar Energy, A Complement To FTA by JUO(m): 3:57pm On Oct 29, 2020
JUO:
5kwh/51.2v at a giveaway
100A charge and discharge continous
650k

1 Share

Re: Solar Energy, A Complement To FTA by ojeysky(m): 3:59pm On Oct 29, 2020
mank1234:


If it passes current above it rating, it will eventually get damaged (through thermsl runaway). It's not meant to be a current limiter.

No, I don't know of a PV current limiter other than the functionality charge controllers provide

Thanks

1 Like 1 Share

Re: Solar Energy, A Complement To FTA by adrusa: 5:31pm On Oct 29, 2020
kiekie1:
SAFETY TIP!

Tubular batteries maintenance cost is relatively high. You must buy batteries with a gallons of distilled water add cost and compare them with maintenance free battery . If you don't maintain battery on time, customer may ask refund or change under warranty time . Don't install these batteries in busy walkways area or closed non breath areas as hydrogen gas is hazardous & can cause fire .

Note: Install all flooded batteries with fireball - fire protection materials

Tubular / flooded deep cycle battery maintenance distilled water & electrolytes now available!

Distilled water 1L (12 in pack) ... 5,000
Distilled water 25L (with free gallon) ... 7,000
Electrolyte (Accurate specific gravity) ...7,000

Direct from chemical industrial plant ! Place your orders now !!


SmartcellNuggets : Once you got a solar panel on a roof, energy is free. Once we convert our entire electricity grid to green and renewable energy, cost of living goes down.

Contact,
Smartcell global services
081-350-31951
WHATSAPP::: https:///2348170385620

I have used my borehole water for my Trojan batteries in the last 6 years. It has served me well. A colleague was paying for distilled water for another type of Trojan, the whole set up last about a year and a half. Luck, I guess. This is not a technical advise on flooded batteries. Follow the instructions of your manufacturer unless you hope to accept personal responsibility for any untowards outcome.

3 Likes

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 8:21pm On Oct 29, 2020
3kva 24v hybrid MUST inverter available, #180,000. Call/WhatsApp us on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 8:22pm On Oct 29, 2020
5kva 48v hybrid MUST inverter now available, #280,000. Call/WhatsApp us on 08168986461

1 Share

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 8:24pm On Oct 29, 2020
200Ah 12v zedix battery now available, #80,000. Call/WhatsApp us on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 8:25pm On Oct 29, 2020
200Ah 12v Ss power battery now available, #90,000. Call/WhatsApp us on 08168986461

Re: Solar Energy, A Complement To FTA by contease(m): 9:51pm On Oct 29, 2020
Goodevening everyone.

I just might need some assistance here please.

I have a system of (Modified Sine wave Inverter) 24v 2.4kva running for only a few days and counting.

Today I realised a strange occurrence, let's say just one for now. For sometime now I have been on a particular FM radio station and only this afternoon I tried to tune to another then realised all my radio stations were gone. Just coincidentally as grid went off, I realised my stations returned inbetween and went dead again on restoration of power (grid went off only a few min).

Went to the inverter and unplugged from grid to feed from batteries and my radio stations returned, please any idea/experience/solution to this?

Just for the info too, I use an external automatic charger of 12Amp to support my inverter of 15amp to 20amp with both connected to grid then battery for a faster charge. I also realised that with the inverter connected to grid and the fm tuned to a known station, the sound system gives some noise without audio then with the charger connected to grid too the sound system gives even more noise still without audio. With both charger and inverter disconnected from grid, sound system works as expected.


I have gone through the link below with no solution :

https://www.solar-electric.com/learning-center/reducing-electromagnetic-interference-pv-systems.html/
Re: Solar Energy, A Complement To FTA by Penuelseun(m): 11:42pm On Oct 29, 2020
contease:
Goodevening everyone.

I just might need some assistance here please.

I have a system of (Modified Sine wave Inverter) 24v 2.4kva running for only a few days and counting.

Today I realised a strange occurrence, let's say just one for now. For sometime now I have been on a particular FM radio station and only this afternoon I tried to tune to another then realised all my radio stations were gone. Just coincidentally as grid went off, I realised my stations returned inbetween and went dead again on restoration of power (grid went off only a few min).

Went to the inverter and unplugged from grid to feed from batteries and my radio stations returned, please any idea/experience/solution to this?

Just for the info too, I use an external automatic charger of 12Amp to support my inverter of 15amp to 20amp with both connected to grid then battery for a faster charge. I also realised that with the inverter connected to grid and the fm tuned to a known station, the sound system gives some noise without audio then with the charger connected to grid too the sound system gives even more noise still without audio. With both charger and inverter disconnected from grid, sound system works as expected.


I have gone through the link below with no solution :

https://www.solar-electric.com/learning-center/reducing-electromagnetic-interference-pv-systems.html/
How is the earthing in your house?

2 Likes

Re: Solar Energy, A Complement To FTA by eleojo23: 11:49pm On Oct 29, 2020
contease:
Goodevening everyone.

I just might need some assistance here please.

I have a system of (Modified Sine wave Inverter) 24v 2.4kva running for only a few days and counting.

Today I realised a strange occurrence, let's say just one for now. For sometime now I have been on a particular FM radio station and only this afternoon I tried to tune to another then realised all my radio stations were gone. Just coincidentally as grid went off, I realised my stations returned inbetween and went dead again on restoration of power (grid went off only a few min).

Went to the inverter and unplugged from grid to feed from batteries and my radio stations returned, please any idea/experience/solution to this?

Just for the info too, I use an external automatic charger of 12Amp to support my inverter of 15amp to 20amp with both connected to grid then battery for a faster charge. I also realised that with the inverter connected to grid and the fm tuned to a known station, the sound system gives some noise without audio then with the charger connected to grid too the sound system gives even more noise still without audio. With both charger and inverter disconnected from grid, sound system works as expected.


I have gone through the link below with no solution :

https://www.solar-electric.com/learning-center/reducing-electromagnetic-interference-pv-systems.html/


It's definitely interference from the inverter and charger. I think your inverter being modified sine wave is also a big factor. I experienced this with only my external charger, my inverter is pure sine wave.

Is the inverter and external charger close to your TV? If yes, try relocating them far from the TV and sound system, that should reduce the interference.

2 Likes

Re: Solar Energy, A Complement To FTA by contease(m): 11:59pm On Oct 29, 2020
Penuelseun:
How is the earthing in your house?

Thank you for your time.

I think so far, the earthing system is good. All "negatives" including that of the inverter AC output "negative" are looped together. I hope this answers the "how" sir.

Before now. Have never had any issue, shock or noise of any form.
Re: Solar Energy, A Complement To FTA by contease(m): 12:05am On Oct 30, 2020
eleojo23:



It's definitely interference from the inverter and charger. I think your inverter being modified sine wave is also a big factor. I experienced this with only my external charger, my inverter is pure sine wave.

Is the inverter and external charger close to your TV? If yes, try relocating them far from the TV and sound system, that should reduce the interference.

Many Thanks for your time.

Been researching too and all I see affirms the cause to be the modified sine wave inverter actually. Though I just realised too that without the external charger connected to power, I get a few more fm stations than when it's connected. Infact I get only 1 fm station.

Also just realised that my single rechargeable bulbs too either dont charge or just don't stay ON when I intentionally turn off all power including inverter... Lol... Not important/needed anymore though grin

Both the inverter system and sound system are in the extreme of an "L" location of two separate rooms apart (just to describe).
Re: Solar Energy, A Complement To FTA by Penuelseun(m): 5:34am On Oct 30, 2020
contease:


Thank you for your time.

I think so far, the earthing system is good. All "negatives" including that of the inverter AC output "negative" are looped together. I hope this answers the "how" sir.

Before now. Have never had any issue, shock or noise of any form.
does your inverter support such, I mean neutral looping, why don't you try disconnecting the loop, so the output stands as a standalone, then see if such happens again
Re: Solar Energy, A Complement To FTA by earthrealm(m): 7:22am On Oct 30, 2020
ojeysky:
Hello, has anyone used the attached diode connectors before? I want to know if it acts as current limiter if not can anyone recommend a good current limiter (preferably one that can be sourced locally)

doesnt seem to hv that capability, a current limiter should have some inbuilt electronics...no sign of that in that connector IMHO

(1) (2) (3) ... (881) (882) (883) (884) (885) (886) (887) ... (1667) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: 1 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 54
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.