Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 3:08pm On Feb 23, 2022 |
Tip 15: Common Problems and Solutions
Genset runs for 2 to 3hrs and goes off. After cooling, it could run same time duration before shutting down like there is no oil. When this occurs,
*Replace used lubricant oil with a better quality one. *Clean the engine block to eliminate waxed soot. |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 6:49pm On Feb 05, 2022*. Modified: 7:23pm On Feb 20, 2022 |
Tip 14: Common Problems and Solutions
Hard Starting after a complete dry out of fuel.
This challenge occurs occasionally when your genset goes off by itself after consuming its tank fuel. After refilling the tank with fuel, you notice the genset cannot startup as usual. In this instance;
* Change or clean the spark plug, put some fuel droplets into the spark plug hole. * Fit in the spark plug back and start the gen again. * Service your carburettor if the above options fail to start the gen. |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 10:01pm On Feb 01, 2022 |
Naijablackboy: Please do you have any small tiger generator for sale? A friend needs it in Epe, Lagos state. Brand New : ₦45k Used: ₦26k |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 11:31am On Jan 19, 2022 |
Generaloluseye: Good morning Engineer. I have a laundry business and I need to buy a generator that can power a 2200watts Iron and a fan. What KVA will be appropriate? And what brand of generator is the best. N.B I intend using it with AC 1.5hp later Estimate: Iron = 2200w Fan = 150w AC = 1.5hp *1.8*745 ~ 2000w Total: 4350w ~ 5.5Kva |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 12:34pm On Jan 18, 2022 |
InfinixMine: Good morning,
Engineers please where can I get this fuel valve?
Kindly assist. Thank you Ladipo Oyingbo Owode Odu ade (Orile) |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 10:56am On Jan 18, 2022 |
Tip 13: Common Problems and Solutions
Lubricants Use *A wide variety of lubricant oils can be used to run the genset. However, ensure you use 2cups of oil per 4liters fuel measure. *Using used oil is not bad but increases the times you service the genset. *Never try to manage and run on less oil as this will cause damage to the engine. |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 5:32pm On Jan 14, 2022 |
Tip 12: Common Problems and Solutions
Engine Sitting /Damper legs * To have long lasting damper legs, after installing, fill empty space with a soft material e.g nylon or foam. This ensures the damper stays firm during workings of the generator. |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 5:27pm On Jan 14, 2022 |
Harpheez50: Hi, I use elepaq key starter and I feel it consumes too much of fuel that 5 liters lasts for less than 5 hours. Is this normal or there’s something i need to fix? Adjust the engine firing screw to reduce engine speed to acceptable level. |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 11:35pm On Jan 13, 2022 |
samutd4u: Please my generator elepaq contact 3.5kva is making noise as if there’s no fuel inside and sometimes the bulb 6w started blinking please what can I do *Service or replace your carburettor. *Check if fuel mixed with water in tank. Drain tank and replace fuel if suspect. *Ensure your fuel line is not restricted by any blockage. |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 3:04pm On Jan 13, 2022*. Modified: 11:29pm On Jan 13, 2022 |
Flash sale!! Used 5.6kva thermocool generator @ 160k. Generator is in good condition. Client is relocating and wants to dispose. 080-64- 172-810
|
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 2:50pm On Jan 13, 2022 |
joncan12: Hi pls am having big issue with my sumec 1800 gen,I have used it for about 3 years now,it shorts oil so bad,make bad noise ,so my engineer told me to change the piston, connecting rods,clown chaft,,but after changing all this still the gen continued short oil,giving me serious hard to start I don't know wat to do again pls advice Dispose genset and get a new one. |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 10:50pm On Jan 12, 2022 |
andrewbaba44: Strong enough for pumping machine right ? What is the power rating of the pump ? |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 10:20pm On Jan 12, 2022 |
KillIgbohoN0W: Wow. I don learn something.
Which is more economical to use please in terms of fuel consumption? Diesel generator is usually more economical when you compare same capacity with a petrol option. |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 10:18pm On Jan 12, 2022 |
andrewbaba44: Please bro’s ,what’s the KVA of this gen ? 4KW*1.25 = 5KVA |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 1:34am On Jan 12, 2022*. Modified: 1:44pm On Jan 12, 2022 |
Babajideteeboy: Good morning all, please I need an engineer to help out. I do laundry, I need to purchase a generator that can carry 2 industrial iron, TV, 2air conditionals, 2fans and a freezer. My question now is: 1. Is there any generator that can power these efficiently that uses petrol? 2. Better still will you recommend a diesel generator? 3. What kva will power these efficiently? Thanks as I look forward to your counsel. Estimate: 2 Industrial irons = 2*2000W = 4000W 2 Airconditions = 2*1200W = 2400W 2 Fans = 2*100W = 200W 1 Freezer = 1*1500W = 1500W Total: *8100W* = 10KVA 10KVA Diesel Genset will just be adequate |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 5:18pm On Jan 11, 2022*. Modified: 8:08am On Jan 14, 2022 |
africo13610: I need a neatly used Tiger Generator.......Lagos only ₦23,000 each 080-64-172-810
|
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 1:50pm On Jan 11, 2022 |
africo13610: I need a neatly used Tiger Generator.......Lagos only Currently available for ₦22k. Cheaper options have pending repair issues. |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 10:38pm On Jan 10, 2022*. Modified: 7:33pm On Apr 10, 2022 |
Tip 11: Common Problems and Solutions
Leaking Fuel Tank: * Identify point of leakage * Drain the tank of fuel completely and allow to dry out. * Scrape around and on the leakage point. * Apply 4mins glue to the scraped area and on the leak point. * Allow to dry before refueling tank. * If leakage persists then weld leak point. However if leaks occur from multiple points, then it's advisable to replace tank. |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 10:23pm On Jan 10, 2022 |
johnfem321: Hello house.. what is the main difference between this two thermocool gen and which one is more fuel efficient ? Both are fuel efficient at point of purchase. Efficiency drops as depreciation of the engine occur over time when being used. |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 5:12pm On Jan 10, 2022 |
Psalmpy: Just TV set 43 inch and fan, I don't know if it can power a small table fridge The generator will power above loads comfortably. |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 4:42pm On Jan 10, 2022 |
Dollywood: My generator is puffing out dust smokes which stains the wall black and I can't figure out what could be the cause? I was thinking maybe it was shortage of oil. Please a very fast reply will much appreciated. Seems your exhaust is leaking. Repair by welding opening or replace with new exhaust. |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 9:15pm On Jan 09, 2022 |
WarriAproko: What causes Gen voltage to drop from 230 to 228 with no load. Product is heir thermocool optimun blue. 3.7kva Your generator's AVR regulates the output voltage continuously within designed limits. 228VAC and even 220VAC output without load is fine. |
Technology Market › Re: Professor On Any Type Of Generator. by RepairZone: 10:17pm On Jan 08, 2022 |
boik: Please my generator key has refused to start the generator. This is the first time I'm seeing this since I bought it in 2020. When I turn the key it doesn't even make any sound. Please what could be the issue and what can be done? Replace the rechargeable battery. |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 9:00am On Jan 08, 2022 |
Tip 10: Common Problems and Solutions
Best way to switch off genset. *First disconnect load from main change over switch, *Lock the fuel tank *Off the start switch *Move caburator lever arm to close position |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 6:56pm On Jan 07, 2022*. Modified: 6:02pm On Apr 16, 2022 |
Tip 9: Common Problems and Solutions
Irregular noise while genset is running *Low oil / fuel ratio in fuel tank. Put more oil. *Bearing or its sitting damaged. Check and correct, repair or replace. *Worn armature coil cover. Pad with metal or rubber washer. Better still replace. * Check and adjust cooling fan position on shaft if necessary to prevent it touching the coil cover case. |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 7:45pm On Jan 06, 2022*. Modified: 7:06pm On Apr 09, 2022 |
Please revisit Tip 2 on calibration of gen on load. Your startup load should be two ceiling fans or similar inductive load. Most homes have a stabilizer and so this can be used in place of a multimeter to monitor and set the desired firing speed of the generator. *Make sure no bulbs are on until this setting activity is completed. *Repeat for every service or new genset commissioning. *Used good Tiger genset is currently available for ₦22k. Cheaper options have pending repair issues. *New Tiger gen cost ₦40k to ₦50k depending on the brand. incogni2o: What of more common problems
Blowing all your electrical appliances. A few of my appliances damaged in last 3 years.
Home theater 3 to 4 Rechargeable fans Uncountable number of bulbs Uncountable number of phone chargers Laptop chargers. Servicing and changing part multiple times.

I still try to convince myself it saves me money though.
Funny enough, someone came in my compound and stole it some days ago. I don't know if I should get another cos I am always consious of savings.
Anyways, if you have a good one to sell, mention me.
Or maybe try to diagnose my problem with this Gen.
By the way I have a bigger gen |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 4:09pm On Jan 06, 2022*. Modified: 10:33pm On Feb 04, 2022 |
Tip 8: Common Problems and Solutions
Gen refuse to start or hard starting experienced whilst normal pulley start rope pressure appears normal. *Check if fuel is in the tank. *Confirm spark plug and caburator are fine. *Check or replace ignition coil unit. *Adjust main engine throttle screw so that it drags the spring loaded inlet valve of carburettor to be in shut position before startup. *Replace leaking and worn engine oil seals to improve suction pressure into engine block. |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 7:44pm On Jan 04, 2022*. Modified: 7:04pm On Apr 09, 2022 |
Tip 7: Common Problems and Solutions
Gen refuses to start easily and low pressure felt from the pulley start rope. *Confirm spark plug and carburator are fine. *Dismantle genset and replace worn engine oil seal. When this is replaced, it prevents leakage and ensures that the right pressure builds up for combustion in the engine block. |
Technology Market › Re: Please Help Fridge Not Cooling by RepairZone: 12:00am On Jan 04, 2022 |
Your cooling circulation fan is probably stuck or faulty. Get a refrigeration technician to check it out and replace if bad. |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 7:13pm On Jan 03, 2022 |
Tip 6: Common Problems and Solutions
Genset runs abnormally, high, low, etc *Service genset *Clean, service or replace caburator *Clean or change spark plug. |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 11:28am On Jan 03, 2022 |
Tip 5: Common Problems and Solutions
Genset runs for 20-30mins and shuts off. *Add more oil to genset * Replace Piston and Rings. * Replace Engine block (optional) if inner lining is rough and no longer smooth. * Ensure engine cooling rubber is in place to avoid overheating of engine block. |
Technology Market › Re: ABC Of Tiger Generator ( I Pass My Neighbour) by RepairZone(op): 7:56am On Jan 03, 2022*. Modified: 9:03am On Jan 08, 2022 |
Tip 4: Common Problems & Solutions
Genset running but no output power: *Check your power plug and cable for open point or breaks. *Check and replace the genset overload switch if faulty. *Replace the capacitor. |