Science/Technology / How To Reset Or Get Back The Root Password Of Huawei MA5683T? by zoeduan: 3:36am On Apr 09, 2018
How to reset or get back the root password of Huawei 5683T?

A1, you can try to Load the empty database matched the device again through DoS. After restarting the device, log in to the system by using the default root password admin (OLT) or mduadmin (MDU). This method will lead to loss of data configurations and the user needs to configure the data again.

A2,I have another way:
Modify the configuration file using the [url=http://www.thunder-link.com/support/U2000V100R006C02SPC301-Installation-Introduction_Part%201.html]U2000[/url].
On the U2000, choose Administration > NE Security Management > LCT User Management from the main menu.
On the LCT User Management tab page, select NE User and then Device Type. Select the desired device name from the Device Name column and user name from the Name column. In the displayed dialog box, choose Set Password to set the new password.
Science/Technology / How To Reset Or Get Back The Root Password Of Huawei MA5683T? by zoeduan: 4:47am On Mar 23, 2018
To reset or get back the root password of MA 5683T
A1, you can try to Load the empty database matched the device again through DoS. After restarting the device, log in to the system by using the default root password admin (OLT) or mduadmin (MDU). This method will lead to loss of data configurations and the user needs to configure the data again.

A2,I have another way:
Modify the configuration file using the [url=http://www.thunder-link.com/support/U2000V100R006C02SPC301-Installation-Introduction_Part%201.html]U2000[/url].
On the U2000, choose Administration > NE Security Management > LCT User Management from the main menu.
On the LCT User Management tab page, select NE User and then Device Type. Select the desired device name from the Device Name column and user name from the Name column. In the displayed dialog box, choose Set Password to set the new password.
Science/Technology / Information About Huawei S7700 Switches by zoeduan: 8:24am On Feb 12, 2018
The Huawei S7700 series switches (S7700 for short) are high-end smart routing switches designed for next generation enterprise networks. The S7700 design is based on Huawei's intelligent multi-layer switching technology to provide intelligent service optimization methods, such as MPLS VPN, traffic analysis, comprehensive H-QoS policies, controllable multicast, load balancing, and security, in addition to high-performance Layer 2 to Layer 4 switching services.
Science/Technology / Visibility Issue Of The RTN-910 Through Different Clouds (UBR). by zoeduan: 5:14am On Jan 03, 2018
Issue Description
In a network we have  iManager U2000 NMS & the MW NEs are RTN 900 & some of the UBR links which need to visible on the NMS. Now when we are going to visible the RTN 910 which are behind the UBR links, getting problem for the visibility.

Please find the picture, as per the actual network.

Handling Process
Since the DCC was flowing through HW-ECC protocol we could not make E and F visible. Now we give IP in A,BC,D,E,F in such a way that the IP of A becomes the gateway of B, IP of B becomes the gateway of C and so on.
Then we try to search for E and F and easily got E and F visible in NMS.
Science/Technology / COMMUN_FAIL And BD_STATUS Alarms Reported On Main And Extended Subrack by zoeduan: 9:10am On Dec 26, 2017
COMMUN_FAIL and BD_STATUS alarms reported on main and extended subrack due to a locked AUX board.
Issue Description:
Over an Huawei OSN 3500 that have extended subrack, Alarms of BD_STATUS appear over the boards(PQ1, XCE, PIU and FAN) of the extended subrack, and COMMUN_FAIL(SXCSB, SL64,EFS0,EGS4,SLQ16) over the main.
Root Cause:
In cases like this, the most probable cause of this problem is the Huawei AUX board. It was necessary to check if was the AUX of the main or the Extended Subrack.The AUX board is take as the main point of failure in this case because it realizes communication between boards in the subrack.
Science/Technology / Anomalies Occur After Main Subrack Becomes Extended Subrack by zoeduan: 7:53am On Dec 18, 2017
Issue Description
Change the running Huawei OSN 3500 from a main subrack into an extended subrack. Mount the extended subrack to a newly created Huawei OSN 3500. Query the physical slots of the extended subrack. It is found that the boards in the extended subrack fail to be displayed and that the tributary boards in the extended subrack are displayed as off-service on the T2000.

Handling Process
1.Check the connection between the main subrack and the extended subrack. It is found that the connection is normal.
2.Perform warm reset on the Huawei SCC board and the Huawei AUX boards in the main subrack and in the extended subrack. It is found that the problem persists.
3.Remove the off-service boards and then insert the boards back to force the boards to perform cold reset. Then, the boards obtain the new slot IDs. The problem is solved.
Science/Technology / EPL Service Does Not Work After Configuration by zoeduan: 9:25am On Nov 13, 2017
There are two [url=http://www.thunder-link.com/HUAWEI-OPTIX-OSN3500_p187.html?search=OSN%203500]OSN 3500[/url], we config one EPL service with exterior port attribute is Hybrid, but we can not ping successfully with no VLAN message after configuration.

The GSCC version is 5.21.31.35;
The data [url=http://www.thunder-link.com/ES1D2VS04000_p957.html?search=SERVICE%20BOARD]service board[/url] is N1PEG8;

Handling Process

1,Creat the service firstly and then change the port attribute to Hybrid secondly, the service will be ok.

2,If the problem has happened, we should change the port attribute to ACCESS and change it to Hybrid again, then the service will be ok.

3,Change the UNI port attribute from Hybrid to ACCESS for both resource node and sink node(of course it should accord with the service need).

This problem exsit for all the V2R11 versions of NG-SDH, we can upgrade to the V2R11C00SPC300 and its later versions to solve this issue ultimately.

(1) (of 1 pages)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 36
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.