₦airaland Forum

Welcome, Guest: RegisterLoginWith GoogleTrendingRecentNew

Stats: 3,331,208 members, 8,449,161 topics. Date: Tuesday, 21 July 2026 at 11:39 AM

Toggle theme

DAVEZONIGLTD's Posts

Nairaland ForumDAVEZONIGLTD's ProfileDAVEZONIGLTD's Posts

1 2 3 4 5 6 7 8 ... 26 27 28 29 30 31 (of 31 pages)

EducationRe: Admissions At King's University Edmonton Canada by DAVEZONIGLTD: 11:53pm On Jan 02, 2014
Any engineering course at king university? When its best time to apply for my son? Dnlbuss@gmail.com
PoliticsRe: Jonathan's Message to Nigerians on New Year & New Century Of Amalgamation by DAVEZONIGLTD: 7:37pm On Dec 31, 2013
yussuff: Mr failure. We'll love to hear more of your promises in 2014. More committee's. More privatisation. More banning. Happy new year to you sir.
so you want to hear from mr failure? As for me and my home, we shall always hear from MR SUCCESS.
AutosRe: Borehole And Soil Investigation Drilling Rig for Sale by DAVEZONIGLTD(op): 9:53pm On Dec 30, 2013
Keep call coming and happy new year.
PropertiesRe: Call us for your Pile Load Test & PIT. (pic) by DAVEZONIGLTD(op): 9:45pm On Dec 30, 2013
Happy new year.
AutosBorehole And Soil Investigation Drilling Rig for Sale by DAVEZONIGLTD(op):
Do you need Borehole and Soil investigation drilling rigs?

We have direct supply from our Italy office.

Contact us today for good price quote.

Info@davezonigltd.com
info@projectdrill.it.
+2348034261643

CelebritiesRe: Mercy Johnson Donates Items To Widows In Uromi, Edo State (photos) by DAVEZONIGLTD: 5:26am On Dec 30, 2013
blaqoracle: 5000 widows is both unimaginable and bogus. you mean there are 5000 widows in local gov areas were the eligibl e votes where not up to 50000 people.do the rest calculation no your own.
the bags of rice viewing there not up to 100, maybe Op means 50bags. 5000 bags of rice with other item mentioned will gulp 75million Naira.
PropertiesRe: Call us for your Pile Load Test & PIT. (pic) by DAVEZONIGLTD(op): 10:36pm On Dec 26, 2013
wishes all our numerous customers Merry Xmas and prosperous year 2014.
Nairaland AdsRe: Discussion Of Nairaland's New Targeted Ads by DAVEZONIGLTD: 10:00pm On Dec 26, 2013
@ Oga Seun. Thank you for crediting my account, but am still waiting for my add to be live on property section. NOTE! dont mind mind if it will appear few hours in a day. thank
Nairaland AdsRe: Discussion Of Nairaland's New Targeted Ads by DAVEZONIGLTD: 12:26pm On Dec 26, 2013
Seun: Sir, please follow the regular procedure.for notifying us about payments.
Scan copy of the teller to you since yesterday but up till now no update on my account and my add is still pendinghuhhuhhuhhuhhuhhuhhuhhuhhuhhuh??
PropertiesRe: Call us for your Pile Load Test & PIT. (pic) by DAVEZONIGLTD(op): 12:39pm On Dec 25, 2013
Contact us today for all your: Soil Investigation, Piling Foundation, Shoreline Protection, General Marine Constructions, Jetty Construction and Pile Load Test.

www.davezonigltd.com
+2348034261643
PropertiesCall us for your Pile Load Test & PIT. (pic) by DAVEZONIGLTD(op):
METHOD STATEMENT FOR THE
PERFORMANCE OF COMPRESSIVE PILE LOAD TEST
(Kentledge Method)















By: Davezo Nigeria Limited
www.davezonigltd.com


TABLE OF CONTENTS


1.0 INTRODUCTION

2.0 PREPARATION

3.0 EQUIPMENT

4.0 ARRANGEMENT

5.0 METHOD OF LOADING

6.0 GENERAL SAFETY PRECAUTIONS

7.0 MEASUREMENT OF PILE MOVEMENT

8.0 PRESENTATION OF RESULTS


ATTACHMENT



1.0 INTRODUCTION
This Method Statement gives a brief description of the procedure for executing a pile load test under a static axial compressive load generated by a kentledge (dead weight) for working piles. In the alternative, pile reaction system could also be applied on request.

A load test is executed on piles for the purpose of verifying its statistically computed Safe Working Load (S.W.L.).

The pile load tests shall be carried out in accordance with specification contained in either of the following procedures:

a) ASTM D1143-81 “Standard Test Method for Piles Under Static Axial Compressive Load”
b) BS 8004 “Code of Practice for Foundations”

The maximum vertical load to be applied on the test pile shall be 1.5 times the estimated Safe Working Load (S.W.L.). 1.5 x SWL

As a general rule, the kentledge weight provided shall be at least 10% greater than the desired maximum load.


2.0 PREPARATION
The top section of the test pile shall be above the existing ground level at a required height while the top surface must be a perfectly horizontal support face.

3.0 EQUIPMENT
Equipment required for a compressive pile load test generally include the following:

S/no. Description Qty. (nos.)
1 Test Beam (Primary) 1
2 Test Beam (Secondary) 14
3 Bearing Plate 3
4 Hydraulic Jack of appropriate capacity 1
5 Oil Manometer of suitable capacity 1
6 Steel Reference Beam 2
7 Dial Gauge capable of measuring movements within an accuracy of 0.01mm 2
8 Glass Plate 2
9 Kentledge of appropriate quantity (Precast concrete piles of various lengths)


4.0 ARRANGEMENT
Arrangement of the load test equipment for the kentledge method shall be as follows:

a) Two equi-distant support lines (between 2 to 4m) are established from the test pile position.
b) A steel plate of adequate thickness shall be placed centrally on the pile top and the hydraulic jack placed on the steel plate afterwards.
c) A set of bearing plates shall be placed on the hydraulic jack.
d) The primary beam shall then be placed over the hydraulic jack with a steel plate in between them.
e) The primary beam shall be placed parallel to the established supports.
f) To ensure that there is a clearance between the primary beam and the jack, temporary supports shall be provided for the primary beam. As a minimum, the beam bottom level shall be at the same level as the top of the established primary beam supports, which should not be more than 50mm above the top of the plate on the hydraulic jack.
g) The secondary beams shall then be placed over the established secondary beam supports.
h) Afterwards, the precast concrete piles shall be symmetrically arranged to span across the secondary beams.
i) The reference beams, each with one end set in concrete and the other free shall be placed about 500mm from both sides of the pile cap. The free end is to allow movement of the beam as its length changes with temperature variation.
j) The dial gauges (minimum of two numbers) shall be fastened to the reference beams. The dial gauge needle shall be made to rest on the flat glass plates, which are glued to the steel plate placed on top of the test pile head.

A schematic presentation of the above arrangement is presented in the attachment (drawings Plates 01).

Note
Where two or more jacks are used, their piston shall be of the same diameter and they shall be connected to a single pressure gauge and pump by means of a manifold. For the purpose of this project a single jack will be utilised, which shall be connected to a single pressure gauge and pumped by means of a manifold.


5.0 METHOD OF LOADING
The Maintained Load Method shall be adopted for the pile load test. The maximum load to be applied on a working pile for this method shall not exceed 1.5 x S.W.L

The load shall be applied in increments of 25% of the design load. Each load increment shall be maintained until the rate of settlement is not greater than 0.25mm/hour or until 1 hours have elapsed, whichever occurs first.

The maximum load shall be maintained on the pile for 12 hours except in the event that the average rate of settlement is not greater than 0.25mm/hour.
Unloading of pile shall be done in decrements of 25% of the maximum load.

The following loading and unloading phases shall be adopted for the load test:

Design Load % Minimum load holding time
First Cycle
0% S.W.L. 10 minutes
25%S.W.L. 30 minutes or 0.25mm/hour
Loading 50% S.W.L. 30 minutes or 0.25mm/hour
75% S.W.L. 30 minutes or 0.25mm/hour
100% S.W.L. 6 hours or 0.25mm/hour
75% S.W.L. 10 minutes or 0.25mm/hour
Unloading 50% S.W.L. 10 minutes or 0.25mm/hour
25% S.W.L. 10 minutes or 0.25mm/hour
0% S.W.L. 30 minutes or 0.25mm/hour
Second Cycle
100% S.W.L. 60 minutes or 0.25mm/hour
Loading 125% S.W.L. 60 minutes or 0.25mm/hour
150% S.W.L. 12 hours or 0.25mm/hour
125% S.W.L. 10 minutes or 0.25mm/hour
100% S.W.L. 10 minutes or 0.25mm/hour
75% S.W.L. 10 minutes or 0.25mm/hour
Unloading 50% S.W.L. 10 minutes or 0.25mm/hour
25% S.W.L. 10 minutes or 0.25mm/hour
0% S.W.L. 30 minutes or 0.25mm/hour


6.0 GENERAL SAFETY PRECAUTIONS
General safety precautions to be adhered to in the testing of a pile under axial load are as follows:

a] All tests should be carried out only under the direction of an experienced and competent engineer conversant with the test equipment and test procedure. All personnel operating the test equipment shall be trained in their use.
b] The kentledge foundation and that for any cribwork, beams or other supporting structure, should be constructed in such a manner that there will not be differential settlement, bending or deflection of an amount that constitutes a hazard to safety or impairs the efficiency of the operation. The kentledge shall be adequately bonded, tied or otherwise held together to prevent it from falling apart or becoming unstable as a result of deflection of the supports.
c] Care should be taken to ensure that when the hydraulic jack and load-measuring device are mounted on the pile head, the whole load would be stable up to the maximum load to be applied.
d] The dial gauges should be situated in a position that will enable test personnel read them clear of the kentledge.
e] The hydraulic jack, pump, hoses, pipes, couplings and other apparatus to be operated under hydraulic pressure should be capable of withstanding a test pressure of at least 1½ times the maximum working pressure of the pile without leaking.
f] The maximum test load or test pressure to which the pile is being subjected to (expressed as a reading on the gauge in use) should be displayed and all operators shall be aware of this limit.


7.0 MEASUREMENT OF PILE MOVEMENT
Before and after the application of each stage of loading and unloading, readings shall be taken at two opposite sides of pile cap by means of the dial gauges.

Where the rate of settlement does not show any appreciable difference in two consecutive readings, the reading shall be taken at a reasonable interval or when next stage of loading or unloading is performed.


8.0 PRESENTATION OF RESULTS
On completion of stages of loading and unloading, a fully detailed set of recorded data shall be submitted to the Project Engineer.

The recorded data shall show, as appropriate to the pile type and method of testing, the following information:
• Contract identification
• Site location
• Main contractor’s name
• Client
• Control Staff (Contractor’s / Client’s Representatives)
• Date of pile installation and concreting
• Type, size and length of pile (as pitched and as driven)
• Reinforcement details
• Date of pile load test
• Pile identification number
• Photographic record of the tests

The test results shall be presented in tabular and graphical form with load plotted against settlement.

AutosRe: 2010 ACURA MDX TECHNOLOGY ( Chevron & Inspired Autos AGAIN ) by DAVEZONIGLTD: 10:44pm On Dec 24, 2013
Need price quote for Gx470 lexus 2006/07 model. Thank
Nairaland AdsRe: Discussion Of Nairaland's New Targeted Ads by DAVEZONIGLTD: 7:10pm On Dec 24, 2013
Seun: Sir, please be patient with us: all the slots in the property section have been occupied, but you are second in line to get new slots when they are available. If two advertisers vacate their slots in that section this weekend, your pending placement will become active. Our system is strictly "first come first served". The only thing we can do in a situation like this is to adjust the price a little bit in order to reduce demand.
@Seun, pls am still waiting for my add to be live on property section.moreover, i just made another payment of 5k today with zenith teller No:4012487.
PropertiesRe: Call Expert For All Your Soil Investigation and Piling Work. by DAVEZONIGLTD(op): 10:06am On Dec 24, 2013
Merry Xmas to all our Friends and Customers.

See you in good health in the year 2014!

AutosRe: Toyota Highlander 2003 For Sale 1.2m by DAVEZONIGLTD: 6:17pm On Dec 23, 2013
any issue with the car? can it fly for 800k ...cash is ready . try and send the pics to david.omotosho@gmail.com
AutosRe: 2003 Toks Nissan Pathfinder For Sale by DAVEZONIGLTD: 9:27pm On Dec 18, 2013
How much?
PoliticsRe: Iyabo Obasanjo's Letter To Her Father by DAVEZONIGLTD: 4:09am On Dec 18, 2013
Will things fall apart in 2015 as America Predicted?? Time will tell.
PoliticsRe: Iyabo Obasanjo's Letter To Her Father by DAVEZONIGLTD: 4:08am On Dec 18, 2013
Things fall apart.
PropertiesRe: Call Expert For All Your Soil Investigation and Piling Work. by DAVEZONIGLTD(op): 4:27pm On Dec 17, 2013
Wishes all our esteem customer MERRY XMAS IN ADVANCE.
Nairaland AdsRe: Discussion Of Nairaland's New Targeted Ads by DAVEZONIGLTD: 10:47am On Dec 17, 2013
Oga seun, kindly assist to send this post to front page pending when my advert will be live on property section. https://www.nairaland.com/1531334/call-expert-all-soil-investigation.

Thanks.
PropertiesRe: Call Expert For All Your Soil Investigation and Piling Work. by DAVEZONIGLTD(op): 10:42am On Dec 17, 2013
Call for Christmas Bonanza Now!!
info@davezonigltd.com
+2348034261643
Nairaland AdsRe: Discussion Of Nairaland's New Targeted Ads by DAVEZONIGLTD: 9:25pm On Dec 16, 2013
Oga seun, please my ad is not yet live on property section. please help as i need customer this dry season.
Properties40hp Lowara Pump For Sale( Bought Direct From Italy) by DAVEZONIGLTD(op):
Lowara Pump For Sale:

Capacity: 40hp
Location: Apapa Lagos
History; Bought directly from Italy office in February this year, used to test a borehole for only one week.
Price: N1,000,000(Still negotiable)


Contact:
Davezo Nig Ltd
info@davezonigltd.com
+2348034261643

PropertiesRe: Call Expert For All Your Soil Investigation and Piling Work. by DAVEZONIGLTD(op): 11:29pm On Nov 26, 2013
Good Pm.

Visit: www.davezonigltd.com
PropertiesCall Expert For All Your Soil Investigation and Piling Work. by DAVEZONIGLTD(op):
For all your Soil Investigation and Piling foundation work, Call expert today!

Davezo Nigeria Limited.
www.davezonigltd.com
info@davezonigltd.com
+2348034261643

PropertiesRe: Property For Sale @ Eleme Rivers State.( View Picture) by DAVEZONIGLTD(op): 9:50pm On Oct 27, 2013
Happy Sunday
PropertiesRe: The Chateau In Ile-oluji: Our Construction Journal by DAVEZONIGLTD: 8:06am On Oct 23, 2013
brabus: Borehole Preparation
Nice job boss!! we look forward for your consideration in regard to our submitted offer.
PropertiesRe: Do You Need Borehole,soil Test And Marine Construction Specialist? by DAVEZONIGLTD: 4:52pm On Oct 22, 2013
Contact @ Davezo Nigeria Limited +2348034261643 davezonigerialimited@gmail.com
PropertiesRe: Do You Need Borehole,soil Test And Marine Construction Specialist? by DAVEZONIGLTD: 4:50pm On Oct 22, 2013
tope777: Davezo Nigeria Limited specialized in the following area:
-Building Construction
-sub soil investigations(CPT/SPT)
-Civil engineering & design
-Shore line protection
-Marine construction
-Industrial and technical supply
-Renovation &maintenance contract
-General contractor.

Call us today for our services.
+2348034261643
+2348073751294

www.davezonigltd.com

PropertiesRe: Property For Sale @ Eleme Rivers State.( View Picture) by DAVEZONIGLTD(op): 4:45pm On Oct 22, 2013
Keep call coming

PropertiesRe: Property For Sale @ Eleme Rivers State.( View Picture) by DAVEZONIGLTD(op):
keep call coming

PropertiesRe: Property For Sale @ Eleme Rivers State.( View Picture) by DAVEZONIGLTD(op): 4:47pm On Oct 19, 2013
Yea

1 2 3 4 5 6 7 8 ... 26 27 28 29 30 31 (of 31 pages)