Dilyschigo's Posts
Nairaland Forum › Dilyschigo's Profile › Dilyschigo's Posts
Please someone should send me Anambra list i can't view the names clearly with my phone . This is email dilyschigo@gmail.com. Thank you |
Zdoh:. Thank you for your advice.My dear it sounds more sweet when saying it. I hv personally gone to sites on my own but seeing the way you as a female they will undermine your capability not knowing that i have jumped foundations, climbed scaffoldings & handled labour forces even the ones that Indian hemp is their second name . |
Good day, i am a female graduate of Civil Engineering from Enugu State University of Science and Technology with 3 yrs experience on site construction, moderate use of autocad, a fast learner and can adapt easily in any related engineering job. Please i reside in Lagos and I am in need of a job and currently unemployed. I have job hunted on most companies but couldn't be allowed to cross the company gate and the ones i succeeded in entering the receptionist are always an obstacle. Please kindly help a soul. |
Pojomojo:. OK Thank you. Pz can you give me the direction to their office from Aguda market Surulere. |
Oxford commercial services Int Ltd owners of Oxford Estates, invites you for an interview. Date; Tuesday 11/4/2017 Time ;10 am Venue; 3rd Avenue ,A close, Plot 140,beside Dominion Cathedral, Gowon Estate, Egbeda, Lagos. (pz do anyone have any idea about this firm. I couldn't get anything about them from Google . Also the direction to the place from Surulere. Thank you) |
Oxford commercial services Int Ltd owners of Oxford Estates, invites you for an interview. Date; Tuesday 11/4/2017 Time ;10 am Venue; 3rd Avenue ,A close, Plot 140,beside Dominion Cathedral, Gowon Estate, Egbeda, Lagos. (pz do anyone have any idea about this firm. I couldn't get anything about them from Google . Also the direction to the place from Surulere. Thank you) |
Oxford commercial services Int Ltd owners of Oxford Estates, invites you for an interview. Date; Tuesday 11/4/2017 Time ;10 am Venue; 3rd Avenue ,A close, Plot 140,beside Dominion Cathedral, Gowon Estate, Egbeda, Lagos. (pz do anyone have any idea about this firm. I couldn't get anything about them from Google ) |
Udochee:. Thank you so much . Pz do you know about them? And are they reliable? Also their criteria? Am going there to know if they have any job to offer. |
Good evening pz i need help. I need the direction on how to go to ICS outsource agency @ Ilupeju. Coming from Ikorodu. Thank you |
Actually my post i wasn't blaming the architect but illustrated the likely cause of the problem. But in all there should be co relationship between Architects & structural engineers for safe structure. |
mayor1115:. Please can you give me details on how you operate. Thank you |
Good day, please i need direction & cost of the transportation fares coming from Enugu to Igbolom Junction Ikorodu. Thank you |
Teacherjobs:. Thank you for the post.I have applied, & i read civil engineering & taught mathematics during my service years. Please what is the criteria for the job. Thank you |
stancydg:. I don't really get your point. Are you saying that long spanning that need introduction of column or depth increase (deflection in check) & was not done can not be a cause of structural failure. |
I read Civil Engineering and experienced in structural works, also open to other areas in Civil engineering.Pz help me with a jobEmail :dilyschigo@gmail.comPhone number :08066139769.* I design and build houses, Set out project works in accordance with drawing and specification* Supervised Building Works, and ServicesBlock work erection,Wall rendering, Foundation works Casting of the structural members* Drainage works , Placing of interlocking stones(paving stones), Walltiles and keb stones.* Conduct on-site investigations and analyze data* Manage, design, develop, create and maintain small-scale through to large-scale construction projects in a safe, timely and sustainable manner |
stancydg:. Yes you are right but on what you said Spanning may not be the cause, i disagree with you on that. Sometimes architects design without considering the safety of the structures and is now the structural engineer that will call him to other. Also in the case of no column & long spanning, the Slab depth should be increased which may not have been done there so i will say that long spanning is still part of the cause. |
Need a Civil Engineer to work for your Company, building construction and services.Contact me @ Email :dilyschigo@gmail.comPhone number :08066139769.* I design and build houses, Set out project works in accordance with drawing and specification* Supervised Building Works, and ServicesBlock work erection,Wall rendering, Foundation works Casting of the structural members* Drainage works , Placing of interlocking stones(paving stones), Walltiles and keb stones.* Conduct on-site investigations and analyze data* Manage, design, develop, create and maintain small-scale through to large-scale construction projects in a safe, timely and sustainable mannerA site will convince you. |
I read Civil Engineering and experienced in structural works, also open to other areas in Civil engineering. Pz help me with a job Email :dilyschigo@gmail.com Phone number :08066139769. * I design and build houses, Set out project works in accordance with drawing and specification * Supervised Building Works, and Services Block work erection,Wall rendering, Foundation works Casting of the structural members * Drainage works , Placing of interlocking stones(paving stones), Wall tiles and keb stones. * Conduct on-site investigations and analyze data * Manage, design, develop, create and maintain small-scale through to large-scale construction projects in a safe, timely and sustainable manner |
stancydg:. Depending on the area you want to construct the Drainage especially Drainage for highways, there is an office in charge of collecting data for the run off(flow) on that particular area which was done through a frequency analysis for a particular life time the Road can last like 25 yrs etc & the peak flow was determined from the frequency collection. So the designer can now go to the office in charge & collect the data for the area he is working on. |
What could be the cause of this building collapse? Happened in Enugu. For me i will say * That loads were not properly distributed * load too much on Foundation due to poor design * The spanning was too long & need the introduction of columns so indeaquate columns * poor quality materials were used & also the strength of the concrete mix used should be checked ( trying to cut costs)
|
abdulwastecx:I believe beam was introduced to the fence because of the water logged soil? |
In building, Drainage is a critical part of the construction project. It is a channel through which waste water can be drain away from buildings quickly and safely. It also eliminate the risk of flooding and health issues that can present significant risk to people and property. WHAT ARE THE FACTORS TO CONSIDER BEFORE CONSTRUCTING A DRAINAGE? * The flow rate calculation of water passing through the Drainage need to be considered before design stage. Sometimes this is overlooked and it results to under or over specification of drainage and compromises during construction stage . * The sloping of the Drainage need to be considered before the design stage to ensure easy flow /run off of water. * Depth of the Drainage need to be considered too because of road construction. MORE CONTRIBUTIONS PLEASE |
In building, Drainage is a critical part of the construction project. It is a channel through which waste water can be drain away from buildings quickly and safely. It also eliminate the risk of flooding and health issues that can present significant risk to people and property. WHAT ARE THE FACTORS TO CONSIDER BEFORE CONSTRUCTING A DRAINAGE? * The flow rate calculation of water passing through the Drainage need to be considered before design stage. Sometimes this is overlooked and it results to under or over specification of drainage and compromises during construction stage . * The sloping of the Drainage need to be considered before the design stage to ensure easy flow /run off of water. * Depth of the Drainage need to be considered too because of road construction. MORE CONTRIBUTIONS PLEASE |
praxs:. Thank you. Amen. |
stancydg:. Thank you so much |
Foundation work (Sub structure work)
|
Foundation work (sub structure work)
|
Residential building
|
Residential building
|
Need a Civil Engineer to work for your Company, building construction and services. Contact me @ Email :dilyschigo@gmail.com Phone number :08066139769. * I design and build houses, Set out project works in accordance with drawing and specification * Supervised Building Works, and Services Block work erection,Wall rendering, Foundation works Casting of the structural members * Drainage works , Placing of interlocking stones(paving stones), Wall tiles and keb stones. * Conduct on-site investigations and analyze data * Manage, design, develop, create and maintain small-scale through to large-scale construction projects in a safe, timely and sustainable manner A site will convince you.
|
Need a Civil Engineer to work for your Company, building construction and services. Contact me @ Email :dilyschigo@gmail.com Phone number :08066139769. * I design and build houses, Set out project works in accordance with drawing and specification * Supervised Building Works, and Services Block work erection,Wall rendering, Foundation works Casting of the structural members * Drainage works , Placing of interlocking stones(paving stones), Wall tiles and keb stones. * Conduct on-site investigations and analyze data * Manage, design, develop, create and maintain small-scale through to large-scale construction projects in a safe, timely and sustainable manner A site will convince you.
|
victord1st:. Yes you can pm on dilyschigo@gmail.com.Am in Enugu. |