Re: Solar Energy, A Complement To FTA by cell7(m): 10:34pm On Oct 13, 2021 |
Thanks. quote author=ceaser post=106712709] I have had POWMR in set-up for the past two years. Some others here too have it in their set ups. None of the four has shown any untoward issues.[/quote] |
Re: Solar Energy, A Complement To FTA by en0uwem: 10:49pm On Oct 13, 2021 |
samnaija:I don't know, but I'll ask the installer tomorrow |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 10:53pm On Oct 13, 2021 |
Quality tier 1 panels only. Talesun 400w solar panel - 80k Call/chat - 08117398294 To order now
|
Re: Solar Energy, A Complement To FTA by whiteMandingo: 1:25am On Oct 14, 2021 |
ajabani4allah: This looks like a local/home made ATS. Show a picture of the front as well, lets see |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 6:41am On Oct 14, 2021 |
cell7: Used it and it's very good for its price 1 Like |
Re: Solar Energy, A Complement To FTA by olopan(m): 7:10am On Oct 14, 2021 |
Is there a way you can open the inside for it to be seen for all and your connection methods can be explain to you ajabani4allah: |
Re: Solar Energy, A Complement To FTA by dejidotun2000(m): 9:32am On Oct 14, 2021 |
I have had one for about 8 months. I have no real complaints but I can't help but wonder if it can really handle the 60A it's supposed to be able to handle. It's cheap and serves my purpose. cell7: |
Re: Solar Energy, A Complement To FTA by dejidotun2000(m): 9:58am On Oct 14, 2021 |
Good day house. Please how does the victron clone fanpusun mppt charge controller with a VOC of 100V react to a PV input voltage in excess of 100V (say 105V). Will I see white smoke or will the CC just stop charging the battery. I am tempted to rearrange my array of 6 X 270W Yingli panels with a measured VOC per panel of 34V from 2s3p (VOC = 68V) to 3s2p (VOC = 102). |
Re: Solar Energy, A Complement To FTA by ewizard1: 10:42am On Oct 14, 2021 |
I build Lithium ion Batteries for Solar systems. For enquiries - +2347038616199. |
Re: Solar Energy, A Complement To FTA by odimbannamdi(m): 10:44am On Oct 14, 2021 |
cell7: It's a pretty good and durable MPPT CC. I have sold almost 6 units of the 60A capacity within and outside Nairaland, and I am yet to receive to a complaint. I also got a new one too, but yet to be installed. Let me know if you would like to purchase it. Selling it for 50,000 firm 2 Likes
|
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 12:42pm On Oct 14, 2021 |
dejidotun2000: This will be lovely to find out from your research! Note: You will see more than 36 v from those panels. I am not advising you to do the connection with 2.5mm, at least, there will be a voltage drop along the wire. so you MAY NOT see up to 100v. BUT why now? Do you just feel like frying something? 1 Like |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 12:44pm On Oct 14, 2021 |
I do not know why some people like to look for trouble |
Re: Solar Energy, A Complement To FTA by Valto(m): 1:33pm On Oct 14, 2021 |
.. 1 Like |
Re: Solar Energy, A Complement To FTA by durodee(m): 5:51pm On Oct 14, 2021 |
Check your WhatsApp! odimbannamdi: |
Re: Solar Energy, A Complement To FTA by odimbannamdi(m): 7:00pm On Oct 14, 2021 |
durodee: We are discussing. |
Re: Solar Energy, A Complement To FTA by ceaser: 7:02am On Oct 15, 2021 |
dejidotun2000: Well, I make it a tradition not to max out the stated capacity of these solar products when I use 'em, either premium or not. So all my 60A POWMR has peaked at 50 amps at most. When I need more power, I simply get extra. So I have two each per set up. Oshomo12: Lol @ bolded. As in? |
Re: Solar Energy, A Complement To FTA by chris81964(m): 9:18am On Oct 15, 2021 |
Valto: Are your cells balanced? 1 Like |
Re: Solar Energy, A Complement To FTA by CAROLYN19: 10:27am On Oct 15, 2021 |
Call/watsapp us on 08066332919 for your Industrial Back Up solution
|
Re: Solar Energy, A Complement To FTA by Valto(m): 10:53am On Oct 15, 2021 |
chris81964:it is balance, but i can help top balance it too. |
Re: Solar Energy, A Complement To FTA by ewizard1: 12:08pm On Oct 15, 2021 |
Super Active Balancer for Li-ion/Lifepo4 Cells Balance current up to 2A. @ N5000 per Cell
|
Re: Solar Energy, A Complement To FTA by dejidotun2000(m): 12:38pm On Oct 15, 2021 |
Hahahahaha . I have dropped the idea. The setup has been running for about a year and I used 6mm cable so I can't count on the cable to reduce the voltage below 100V My reason for wanting to do 3s2p is to reduce the current. One of the MC4 branch connectors to connect the 3p got damaged and the damage seems as a result of overcurrent. I am afraid it will happen again. Oshomo12: |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 2:26pm On Oct 15, 2021 |
Use higher grade MC4 connectors or roll your own branched connector to a suitable spec to avoid burning/melting cables and contacts. When I look at the cable gauges on the main trunks and terminations of those generic Y branch MC4s I am usually not satisfied that they can conduct the rated current long term. I think most MC4s are rated for passing 30A at most. I create my own Y branches with 16mm sq main trunk cable (going to the CC) and 6mm branch wires (going to the panels) fixed to MC4 at one end - 16mm sq and 6mm sq cables come together via a crimped butt connector/ferrule. You can possibly do 3 panels in series but drop your cable gauge to 4mm sq or increase the length of the 6mm sq run so that there are a few volts of losses at the CC end of the cable. A good knowledge of the science of energy transmission (voltage drop over a known distance and given cable gauge) or use of suitable online charts will help you here - also real field conditions vs STC for panel rating are your friend. Please note I am not advocating that you play close to the VoC limit of your CC - I am simply pointing out what is possible given the available tools and knowledge You need to consider that any voltage drop is indeed real useable energy being lost in transmission. dejidotun2000: |
Re: Solar Energy, A Complement To FTA by funshyboi(m): 2:46pm On Oct 15, 2021 |
Dam5reey: I don’t have the manual anymore. Pls simplify your response to make me understand |
Re: Solar Energy, A Complement To FTA by dollarnaira: 6:56pm On Oct 15, 2021 |
funshyboi: He was trying to say that d 1000w is the maximum, usable only for just few mins. 500w load can be run continually for as long as your battery can carry you. That is, never run ur inverter too close to its capacity e.g a 1000w is safely run at 500w etc Hope this is ABC enough? |
Re: Solar Energy, A Complement To FTA by Deluxe8000(m): 7:27am On Oct 16, 2021 |
[color=#000099][/color]Good morning house I noticed that charging my phone using inverter is slow. Charging with phcn is fast. Any solution to this? |
Re: Solar Energy, A Complement To FTA by Penuelseun(m): 7:34am On Oct 16, 2021 |
Deluxe8000:With which type of inverter? |
Re: Solar Energy, A Complement To FTA by Deluxe8000(m): 7:40am On Oct 16, 2021 |
Famicare 1000w inverter |
Re: Solar Energy, A Complement To FTA by olopan(m): 8:04am On Oct 16, 2021 |
I fancy your balancer, please tell me more on how it works and it that a batrium display you posted? ewizard1: |
Re: Solar Energy, A Complement To FTA by olopan(m): 8:09am On Oct 16, 2021 |
I think famicare is modified sine wave inverter but I am not 100% sure just like the mercury inverter using two battery Deluxe8000: |
Re: Solar Energy, A Complement To FTA by ewizard1: 8:42am On Oct 16, 2021 |
olopan:Each cell voltage is converted to a paralleled AC Line. The display is the DIY BMS interface. |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:56am On Oct 16, 2021 |
DISCOUNTED PRICE! HURRY!!! Star plus 12v 220a tall tubular battery Capacity: 220ah Features: - Quick recharge - 2 years warranty - More power - Ultra low maintenance Unit Price: 115,000 Four units above price: 110,000 TWO year's standard warranty! Contact, Smartcell global services CALL ONLY:: 081-350-31951 WHATSAPP ONLY::: http://.us/w/?c=a46ea5
|
Re: Solar Energy, A Complement To FTA by ojeysky(m): 9:08am On Oct 16, 2021 |
ewizard1: So for 16s it's 16x5000? |
(1) (2) (3) ... (1063) (1064) (1065) (1066) (1067) (1068) (1069) ... (1809) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: 3 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 45 |