Re: Solar Energy, A Complement To FTA by mank1234(m): 2:13am On Dec 04, 2022 |
fhranchez: Failing battery will reduced overall AH charged to thr battery as the battery falsely get full very soon but not the instantaneous current. Reduction in current is due to dust. Wash the panel. 2 Likes |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 6:00am On Dec 04, 2022 |
Are u using a lead acid battery. If yes.. Do u av a shunt battery monitor installed in ur system or any type of monitor that shows the amount of amps coming n going out of ur battery? Wat side is ur panel facing. (N, E, S or W) fhranchez: |
Re: Solar Energy, A Complement To FTA by cluewebhost(m): 8:54am On Dec 04, 2022 |
odimbannamdi: I think 540w should be 24v. |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 10:32am On Dec 04, 2022 |
They can both be true. Dust and dirt can lower your PV production significantly. A weak or failing battery can also limit your PV production. You should clean the panels as a first step - this is low hanging fruit. To test if your battery is a culprit, on a clear skies sunny day, disable mains/Gen input, put on a large load while the battery is in absorb or float and see if the PV watts ramp up in response to the load coming on. You could also deep discharge the battery the day before and disable solar charging until 11am - you start up the solar charging while the battery is low and see how the PV responds to a hungry battery under optimal solar weather. You need to pick an ideal solar day to run these tests and also have a backup in case solar will not be sufficient to refill your battery for that day. fhranchez: 1 Like |
Re: Solar Energy, A Complement To FTA by fhranchez(m): 11:00am On Dec 04, 2022 |
Jefferyzz:ques 1: yes, lead acid(gel) Ques 2: shunt, the pwm controller has a amp monitor Ques 3: north or south, I'm not sure |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 11:21am On Dec 04, 2022 |
Not like that. U need a standalone monitor like the 1 below fhranchez:
|
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 11:23am On Dec 04, 2022 |
Who knows if this diodes can function like fuse. They are way cheaper than fuse n fuse holders. More than 2x cheaper sef
|
Re: Solar Energy, A Complement To FTA by ojeysky(m): 11:37am On Dec 04, 2022 |
Jefferyzz: I believe it acts as fuse only drawback is that you can get it in higher amps ranges so if your string current is not high then you are good to go |
Re: Solar Energy, A Complement To FTA by Syber(m): 11:46am On Dec 04, 2022 |
Hey Veterans in the house Which 7kwh (and upwards) Lithium battery can i get that is reliable for my 5kva Gennex Hybrid Inverter |
Re: Solar Energy, A Complement To FTA by ojesymsym: 12:11pm On Dec 04, 2022 |
Is there a way to soft start a freezer compressor? Any device or something that can work? |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 1:28pm On Dec 04, 2022 |
No diodes are not fuses - diodes allow current to flow in only one direction. If I recall correctly a diode burns out if higher than rated amps pass through it - the burnout is in such a manner as may cause a fire or other damage. Fuses are designed to fail safely when the circuit they protect is overloaded. Decent panels usually have diodes built in same as the charge controllers - I am wondering what OP is trying to achieve substituting a diode for a fuse - if the goal is to protect your panels from perhaps some short or other failure then use a combiner box with breakers per string of panels or if you really want to use fuses then take the time and trouble to do it right. ojeysky: 1 Like |
Re: Solar Energy, A Complement To FTA by isangjohnson: 1:56pm On Dec 04, 2022 |
ojesymsym:You may see it but I doubt the effectiveness of it. Someone talked about putting some super capacitors in parallel with his battery, right at the inverter terminals. That would give a big current boost when a high demand load start. I think you need an inverter/battery capable of handling the start up surge. The goal should be to avoid using battery to power freezer, rather using surplus pv while battery is fully charged during the day. |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 2:36pm On Dec 04, 2022 |
NiyiOmoIyunade: Those stuff are actually called fuses(you may Google it) but they act as you've described. Usage scenario is when you don't want current from PV to go above certain level. I was considering this for my home setup at a time but I figured that Deye does cap the current without negative impact. Not all CC does that apparently. |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 3:01pm On Dec 04, 2022 |
Jefferyzz: I have this available for sale incase you want to buy. I think mine are 200A(will reconfirm) |
Re: Solar Energy, A Complement To FTA by sheDD(m): 3:25pm On Dec 04, 2022 |
Any installer around Awka, Onitsha, or Asaba Call me I'd got a job 4 for you. O9132820866 |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 3:48pm On Dec 04, 2022 |
Syber: DIY or Felicity are the ones in town unfortunately. Still yet to see reasonably priced lifepo4 pack that is not DIY 1 Like |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 5:56pm On Dec 04, 2022 |
The purpose is to blowout Incase there's a short higher than 15a. D diode is built inside an mc4 connector. I think that can handle the fireworks. Yh. Current from d panel is meant to flow in 1 direction. Backflow will damage d panel if higher than d figure of max series fuse. N a pair is lesser than price of 1 fuse with d holder. NiyiOmoIyunade: |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 5:56pm On Dec 04, 2022 |
@ fhranchez Incase u need one of the monitor in the picture ojeysky: |
Re: Solar Energy, A Complement To FTA by mctfopt: 6:06pm On Dec 04, 2022 |
NiyiOmoIyunade: You'll be surprised at the stunt some tech people pull off at jobs. I've seen someone bill for 4mm² 3 core flex, one for input and one for output. The tech guy ended up using one of the wires (3 core) for both input and output. How he achieved this is both criminal and at the same time genius. The 3 core wire was used this way, L was used for input live, the neutral wire was used for both input and output neutral (inverters share a common neutral for both input and output) and the third wire, earth, was used for output live. Dude did not really care for earth, "after all it works" So he bought only 30m of cable and pocketed the money for the other 30m meant for output wire. |
Re: Solar Energy, A Complement To FTA by isangjohnson: 6:42pm On Dec 04, 2022 |
Does anyone has victron bmv 712 here? |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 7:03pm On Dec 04, 2022 |
isangjohnson: Kai there is always time for everything sha, I remember when I was actively marketing 2 units of this thing here.... stayed with me for months until someone bought them off |
Re: Solar Energy, A Complement To FTA by isangjohnson: 7:13pm On Dec 04, 2022 |
ojeysky:I knew you don't have it. Business is ups and downs... If more were still with you, you would've probably made extra cash... Lol |
Re: Solar Energy, A Complement To FTA by fhranchez(m): 7:48pm On Dec 04, 2022 |
ojeysky:does it display watts? If not, do you have a watt monitor and how much is it |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 8:19pm On Dec 04, 2022 |
fhranchez: Ofcourse it displays watt and other stuff and I have confirmed I have the 200A shunt version. It's 20k if you are interested let me know
|
Re: Solar Energy, A Complement To FTA by jonescosmo(m): 3:02am On Dec 05, 2022 |
My 16KW Deye + 2x15KW Felicity LPBF48300 Setup is almost complete. Still at the testing phase. 6 Likes
|
Re: Solar Energy, A Complement To FTA by jonescosmo(m): 3:04am On Dec 05, 2022 |
Next 1 Like
|
Re: Solar Energy, A Complement To FTA by sheDD(m): 5:19am On Dec 05, 2022 |
sheDD: Any here!!!!? |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 6:05am On Dec 05, 2022 |
jonescosmo: Am looking at those battery cables, they don't seem to be above 16mm? I will suggest you do 35mm or at least 25mm considering the load as I assume you will be doing up 10kw average? I can even see from the image that you are already discharging at above 11kw 1 Like |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 6:06am On Dec 05, 2022 |
jonescosmo: Oh the BMS does not report individual cell voltages? That's not cool |
Re: Solar Energy, A Complement To FTA by Juror: 7:13am On Dec 05, 2022 |
ojesymsym:are you sure the problem is the starter? |
Re: Solar Energy, A Complement To FTA by Juror: 7:18am On Dec 05, 2022 |
AshipaEk0:Why do you want to walk in? I have one I can sell - send to you, gold color. 36k |
Re: Solar Energy, A Complement To FTA by jonescosmo(m): 7:31am On Dec 05, 2022 |
ojeysky: They are actually 35mm x 2 on each pole. I used single 35mm initially but they were heating up while charging at 240A. So instead of linking the 2 batteries, I let each battery travel to the inverter on its own. Now the heating is gone. I have the breakers to worry about now. It's rated 125A and I'm pumping 240A through it. Instead of it to trip, it's just there heating up. |
(1) (2) (3) ... (1309) (1310) (1311) (1312) (1313) (1314) (1315) ... (1843) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: 1 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 55 |