| Re: Solar Energy, A Complement To FTA by EdmundDantes(m): 9:18am On Feb 26, 2023 |
Good morning. Please, I would like to know where I can get a Deye 5kw inverter and how much it costs. Residing in Asaba, Delta State. Also, between a Phocos 5kw and a Deye 5kw, which should one go for. Taking price, features, quality/durability into consideration. Thanks. |
| Re: Solar Energy, A Complement To FTA by earthrealm(m): 12:15pm On Feb 26, 2023 |
EdmundDantes:@valto has 1 5kw deye for sale . phocos is a great make also. but in terms of features, deye has more features, and is slightly more expensive as well |
| Re: Solar Energy, A Complement To FTA by TechGeek777: 12:27pm On Feb 26, 2023 |
Peterlove11:Do you mind stating your setup (including the Felicity series, idle consumption, battery bank etc). |
| Re: Solar Energy, A Complement To FTA by EdmundDantes(m): 2:44pm On Feb 26, 2023 |
earthrealm:Thanks. |
| Re: Solar Energy, A Complement To FTA by Ajanidokun: 2:47pm On Feb 26, 2023 |
Available Ajanidokun: |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 3:45pm On Feb 26, 2023 |
NiyiOmoIyunade:ok Chief. I get your explanation, but I don't think I agree totally as well. Just the same way the inverter can throttle grid usage, I'm sure in the same way it can dynamically reduce its demand on the gen as pv harvest increases and increase its demand on the gen up until the set input limit before going into passthrough mode, all of this being done without a third-party control loop mechanism_ The system sees a three-phase supply whether gen or grid and acts accordingly. So I think anyways. I wish we have some Victron backend dev here to clarify things better sha. ![]() |
| Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 4:39pm On Feb 26, 2023 |
There are at least 2 to 4 Victron devs here. Sometimes the greatest things come in humble packages. ![]() But to the matter - say your system runs the ESS assistant, the power assist and dynamic current limiter functions of the inverter are disabled/unchecked but ESS has it own way of managing these things. Throttling the Gen load demand implies sufficient PV production to service loads and therefore no need for the Gen to run. If the system calls for the Gen to assist loads or battery charging and is simultaneously throttling the Gen output, you can see how that is not very productive ![]() What you describe typically happens when the Gen was manually started (outside the ESS and GX autostart parameters) or the Generator start/stop was suboptimally setup or the ESS multiphase regulation was set to 'total of all phases' in a 3 phase system with Generator assist or the Gen is oversized for the application. More than one of the above can be true per time. Most customers would struggle with the Gen being started during the day in the face of sufficient PV except you have undersized the PV relative to load demand. There is a scenario where the Gen is needed to support peak loads and if properly done the Gen will be sized to be just able to provide the balance of energy in the system and hence there should be no throttling. In short, the overriding philosophy in all systems I know is to run the Gen as hard as it can handle and not derate or buck under the burden. If the Gen is oversized as Nigerians like to do, then good money was and is just being thrown away. If your design goal is to co-run the Gen efficiently e.g a PV Diesel application that is best done by sizing the Gen properly or failing that an external control loop to force the Gen to run in its most efficient power band per time. If I will leave any nuggets it will be below; 1) In a PV inverter or mixed AC/DC coupled application, ensure Gen is connected to a separate inverter input, designated as Gen on the GX and never manually started (look to the ESS control setpoints and AGS parameters like 'Quiet Hours' to lockout Gen start in the presence of PV) Trippledots: |
| Re: Solar Energy, A Complement To FTA by litaninja(m): 4:49pm On Feb 26, 2023 |
Dang. gadgetplanetng: |
| Re: Solar Energy, A Complement To FTA by mangolpupa: 5:20pm On Feb 26, 2023 |
gadgetplanetng:Sorry for your loss. Couldn't agree more! This country is suffering from a dearth of knowledgeable tradesmen or professionals. it seems no sector is spared: building, plumbers, tilers, electricians, engineers. This problem makes it more appealing for people that are DIY inclined to do a lot of the thinking and gathering of information. In an ideal situation, it shouldn't be. The installer as a solar engineer should have advised of possible scenario (as a Nigerian that understands his environment) and provided solutions. If he tells you, Oga, you need to put SPD here and you say not yet then if something goes wrong, you know you were informed. With the relative high cost of solar installation, such avoidable mishaps can be saddening. Thanks for sharing this experience so that some of us on the journey to solar energy freedom will be encouraged to strengthen our resolve for adequate material/human safety. |
| Re: Solar Energy, A Complement To FTA by FEGEITOK: 5:29pm On Feb 26, 2023 |
mangolpupa:I invited someone to help me with the install. I know what to do, but nothing beats hands-on experience. But there were clearly gaps in his knowledge. I asked about earthing panels, he said it was unnecessary, I insisted on installing protective devices so that I could isolate the battery and the PVs, he said it was unnecessary. This video is proof that you need to install earthing and lightening protection systems for your PV. Or watch your money go down the drain https://www.youtube.com/watch?v=mAQy-IKNuG4. Sadly, this means I have to commit more time to understand what I need to buy, and who I need to buy from to protect my investment so far |
| Re: Solar Energy, A Complement To FTA by viperVIP: 6:15pm On Feb 26, 2023 |
I can only imagine ![]() A quick one here, people that have a high voltage PV array, do you get electric shocks from them when you attempt to wash them? [quote author=FEGEITOK post=121271510] |
| Re: Solar Energy, A Complement To FTA by oloet: 8:29pm On Feb 26, 2023 |
NiyiOmoIyunade:Thank you for this submission, I never thought about it this way |
| Re: Solar Energy, A Complement To FTA by temi4fash(m): 8:59pm On Feb 26, 2023 |
Please i have a 2KVA 24V Genus Proton Inverter, I noticed it stopped charging my batteries up to 26V - 27V, At some point it would not go beyond 25V. Now it does not even charge the batteries at all. It comes on but just shows overload trip even with no load on it. I use 2 nos of 200A 12V Gel deep cycle batteries Can the inverter be repaired? Can any one help recommend some one who can? I also want to install 4 nos of 300W solar Panels, Any ideas what i need to look out for? Thank you very much for the knowledge sharing here
|
| Re: Solar Energy, A Complement To FTA by FEGEITOK: 9:06pm On Feb 26, 2023 |
NiyiOmoIyunade:I consulted you before setting up my PV system. Thanks for your advice. Please can you give me the names of one or two safe electrical isolators that I deploy between the PV and the CC? From the video, I posted earlier today, investing in a proper lightning protection system is a very expensive venture. So let me start with the one that isn't as expensive. Thanks.
|
| Re: Solar Energy, A Complement To FTA by GloriousGbola: 9:21pm On Feb 26, 2023 |
FEGEITOK:
|
| Re: Solar Energy, A Complement To FTA by FEGEITOK: 9:26pm On Feb 26, 2023 |
735i:The scientific way to answer this question is that we need to find out the startup load specific to your 1.5hp inverter AC and inverter fridge. The best way to do that is using a device that measures that startup load. Or alternatively, share it here for others to help you decode, or you yourself studying and decoding the product datasheets.
|
| Re: Solar Energy, A Complement To FTA by FEGEITOK: 9:29pm On Feb 26, 2023 |
[quote author=GloriousGbola post=121278634][/quote]Thanks for coming through for me . It is hard to search when you don't even know the name of what you are looking for. Google only helps you, if you know what you are looking for. Thanks again |
| Re: Solar Energy, A Complement To FTA by GloriousGbola: 9:30pm On Feb 26, 2023 |
FEGEITOK:You are welcome I have been doing some PV design so I have had to do some research ![]() Cheers |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 9:32pm On Feb 26, 2023 |
NiyiOmoIyunade: |
| Re: Solar Energy, A Complement To FTA by GloriousGbola: 9:33pm On Feb 26, 2023 |
FEGEITOK:Theoretically all 'inverter' items are soft/ electronic start and have a much lower starting current than the conventional older models. They also do not have the periodic ramping / kick during operation. |
| Re: Solar Energy, A Complement To FTA by Trippledots(m): 9:33pm On Feb 26, 2023 |
NiyiOmoIyunade: |
| Re: Solar Energy, A Complement To FTA by FEGEITOK: 9:39pm On Feb 26, 2023 |
GloriousGbola:Oh cool. I forgot that those were not conventional. |
| Re: Solar Energy, A Complement To FTA by FEGEITOK: 9:40pm On Feb 26, 2023 |
GloriousGbola:So much they don't tell you to beware when you set out on this journey. If you don't do your own research, you will get burnt. Good luck. This thread has been an eye opener though. |
| Re: Solar Energy, A Complement To FTA by tsiriman(m): 12:29am On Feb 27, 2023 |
viperVIP:I never wash mine online, i have 2 MPPTs on the hybrid inverter, each with a separate isolators installed before the inverter input, so if I want to wash I switch off one MPPT while the other is online and vice versa, when done washing I switch them all back on |
| Re: Solar Energy, A Complement To FTA by TechGeek777: 12:52am On Feb 27, 2023 |
Expects in the house, please an inverter with "Maximum Bypass Overload Current": AC 63A, what will be the equivalent in watts when in bypass mode, is it multiplied by inverter voltage 63a * 48v OR by Nepa Voltage 63a * 220v? |
| Re: Solar Energy, A Complement To FTA by zeestone99(m): 2:00am On Feb 27, 2023 |
TechGeek777:For Ac just multiply by 200 to get approx watts. Normally you multiply voltage, current and power factor.
|
| Re: Solar Energy, A Complement To FTA by TechGeek777: 2:34am On Feb 27, 2023 |
zeestone99:Thanks bro, I understand it now. |
| Re: Solar Energy, A Complement To FTA by samnaija: 9:19am On Feb 27, 2023 |
tsiriman:Apart from this I wash them very early in the morning before the sun picks up and switch of all isolators. Another way wash at night. |
| Re: Solar Energy, A Complement To FTA by samnaija: 9:30am On Feb 27, 2023 |
FEGEITOK:Get in touch with zeestone, he will sort you out on spd. |
| Re: Solar Energy, A Complement To FTA by FEGEITOK: 9:43am On Feb 27, 2023 |
samnaija:Thanks. I will reach out. Today I adjusted the placement of the panels using Optimal Tilt software |
| Re: Solar Energy, A Complement To FTA by ojeysky(m): 9:48am On Feb 27, 2023 |
EdmundDantes:@Valto has 5kw Deye. In terms of quality and durability, Deye it is |
| Re: Solar Energy, A Complement To FTA by Valto(m): 10:57am On Feb 27, 2023*. Modified: 11:15am On Feb 27, 2023 |
ojeysky:sold out since January 24v 280ah lifepo4 lithium battery with brand new grade A 280ah Lifepo4 cells, metal box, 125A circuit breaker, 100A Bluetooth bms e.t.c going for 1,080,000
|