Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / New
Stats: 3,152,624 members, 7,816,571 topics. Date: Friday, 03 May 2024 at 01:17 PM

Solar Energy, A Complement To FTA - Satellite TV Technology (616) - Nairaland

Nairaland Forum / Entertainment / TV/Movies / Satellite TV Technology / Solar Energy, A Complement To FTA (2058096 Views)

UPS Back-up, Also A Complement To FTA / FTA Frequency / Cctv Installation A Complement To Fta And Solar Energy (2) (3) (4)

(1) (2) (3) ... (613) (614) (615) (616) (617) (618) (619) ... (1691) (Reply) (Go Down)

Re: Solar Energy, A Complement To FTA by Valto(m): 9:55pm On Nov 28, 2019
..
Re: Solar Energy, A Complement To FTA by dgr8truth(m): 11:11pm On Nov 28, 2019
I have a 100/50a MPPT fangpusen controller for sale. It is a brand new charge controller never been used. I'm selling for 45k, If you are interested call or whatsapp 08060313355.

Re: Solar Energy, A Complement To FTA by olaolu11(m): 4:39am On Nov 29, 2019
mahkanjuh:

How much does this your 24/7 light cost you?

It was a journey of about five years. I only added the solar panels just recently.

5years ago, luminous inverter was got new for 35k. 100ah Leoch battery for 30k(now bad and out of service), ancillaries(wiring etc) 8k.

Late 2018,
200ah mercury battery 83k,
60a pwm controller 8k on Aliexpress,
25 metres 6mm dual core cable 850/metre,
Four 150watts panels from alaba about 35k each,
Ancillaries(changeover, etc)about 10k.
On average say, at today's cost about 300k
Re: Solar Energy, A Complement To FTA by kiekie1(m): 6:37am On Nov 29, 2019
THE BLACK FRIDAY D-DAY IS HERE! DONT MISS THIS GOLDEN OPPORTUNITY!!!


NOTE: If seriously interested in Black Friday sales opportunity for unit purchase of Trojan, Ultron , Monbat, axpert Ms,Schneider & tbb inverters.. feel free to contact me!


Contact,
Smartcell global services
081-350-31951
WHATSAPP::: https:///2348170385620

Re: Solar Energy, A Complement To FTA by kiekie1(m): 6:42am On Nov 29, 2019
THE BLACK FRIDAY D-DAY IS HERE! DONT MISS THIS GOLDEN OPPORTUNITY!!!


JUST 1 DAY FLASH SALES >> ITS A BLACK FRIDAY SALES !!

1) Ultron made in Korea 200a battery ... 100,000

2) Aspert 1.2kva inverter ... 50,000

3) Schneider 1.5kva inverter .. 60,000

4) USA Trojan 225a flooded battery ... 140,000

5) USA Trojan 205a AGM battery ... 150,000

6) TBB 4000w inverter ...155,000

7) Schneider sw 4048 inverter ...450,000

8 ) Monbat 200a battery ... 116,000

cool Schneider sw 8548 inverter ...999,000

DON'T MISS THIS GOLDEN OPPORTUNITY!


NOTE: If seriously interested in Black Friday sales opportunity for unit purchase of Trojan, Ultron , Monbat, axpert Ms,Schneider & tbb inverters.. feel free to contact me!


Contact,
Smartcell global services
081-350-31951
WHATSAPP::: https:///2348170385620

1 Share

Re: Solar Energy, A Complement To FTA by Solardepot: 3:32pm On Nov 29, 2019
Hello there, #TGIF...

In the spirit of #BlackFriday, we are giving UP TO 30% OFF on all our products.

To get yours, Kindly call the following numbers below
09069125453, 08086071014 or 07014487290

Kindly visit our website on www.solardepotng.com to check out our various products

Don't miss out on this one.

Make your Friday memorable by taking this opportunity


SOLAR DEPOT NIGERIA

Re: Solar Energy, A Complement To FTA by sintolord(m): 6:04pm On Nov 29, 2019
Good day Kiekie, kindly let me know the idle power, max surge power & continuous running watt of the Schneider homaya1500va. Also, does it have voltage selector? Am interested.

kiekie1:
XMAS SALES BY SMARTCELL! DONT MISS OUT!!

(1) Monbat 200a 12v made in EU fta die-hard batteries (June/July manufactured) ... 116,000 per unit , 115k 4 upwards !

(2) USA Trojan 12v 205a die-hard deep cycle batteries fresh from the oven .... 170,000 160000 for two units upwards

(3) Durable Made in China Oliter 12v 200a agm battery ... 92,000 per unit , 90k for two units upwards

(4) Morningstar 45a mppt charge controller ... 140,000

(5) Morningstar 60a mppt charge controller ....190,000

(6) Schneider 1.5kva 24v solar inverter ...... 68000 per unit , 66000 two units above

(7) Set of foreign solar panel roof mounts which can take up to 4 units of 300 to 400w panels ... 28,000

(cool Quanta amaron 200a white carton battery ... 122000 per unit , 120000 for two upwards

What are you still waiting for ??

PLACE YOUR ORDERS NOW !!!


Contact,
Smartcell global services
081-350-31951
WHATSAPP::: https:///2348170385620

1 Like

Re: Solar Energy, A Complement To FTA by kiekie1(m): 7:51pm On Nov 29, 2019
sintolord:
Good day Kiekie, kindly let me know the idle power, max surge power & continuous running watt of the Schneider homaya1500va. Also, does it have voltage selector? Am interested.


Hello Sint, it's basically a solar pure sinewave inverter with low idle consumption .

Quick Overview ;
Proven value for off-grid, backup power and self-consumption

ConextTM SW is perfect for off-grid, backup power and self-consumption applications, it is a pure sine wave, hybrid inverter system with switchable 50/60 Hz frequencies, providing power for every need. For expanded off-grid capacity, the Conext SW is integrated with fuel-based generators as required to support loads larger than the generator’s output.

It’s also self consumption ready, able to prioritize solar consumption over the grid, while maintaining zero grid export. The Conext SW works with the grid to avoid peak utility charges and support the grid when utility supply is limited. Accessories include pre-wired universal DC distribution panel and AC distribution panels. Stacking two Conext SW units will double the system’s total output power and available solar charge controllers allow for the integration of solar capacity as required.

Kindly call my details in advert for purchase or outright order from Lagos to any state as usual .. Thanks
Re: Solar Energy, A Complement To FTA by mahkanjuh: 11:05pm On Nov 29, 2019
olaolu11:


It was a journey of about five years. I only added the solar panels just recently.

5years ago, luminous inverter was got new for 35k. 100ah Leoch battery for 30k(now bad and out of service), ancillaries(wiring etc) 8k.

Late 2018,
200ah mercury battery 83k,
60a pwm controller 8k on Aliexpress,
25 metres 6mm dual core cable 850/metre,
Four 150watts panels from alaba about 35k each,
Ancillaries(changeover, etc)about 10k.
On average say, at today's cost about 300k
Thanks very much bro, i really appreciate
Re: Solar Energy, A Complement To FTA by mahkanjuh: 11:06pm On Nov 29, 2019
simydan:


For a 750w to run 18hrs:
750×18=13500w
13500+2700=16200w

For 750w to run 24hrs
750×24=18000w
18000+3600=21600w

To run a 16200watts or 21600watts load, you need about 15pcs to 20pcs of 200ah battery
2kw inverter.
Charge Controller
3000watts panels or more...
Cables and breakers.

That will cost a fortune, seriously talking of millions.
But, in the real sense a 750w load will not be run at once so, practically you may end up running say about 400w or even less at any given time so that makes the system cost effective and more realistic.

You can contact me for proper costing and advice.
Thanks for this wonderful answer bro, but you didn't drop your contact.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 7:45am On Nov 30, 2019
PROMO/FLASH SALES! ALL BRAND NEW WITH WARRANTY!!

1) Axpert 1.2kva 12v pure sinewave lcd inverter ..50000

2) Schneider 1.5kva 24v Solar/hybrid pure sinewave inverter ... 71,000

3) Axpert 3kva 24v solar/hybrid pure sinewave lcd wall mount inverter with inbuilt 80a total charge current .... 110,000

YOU CAN PICK UP IF BASED IN LAGOS OR SIMPLY PLACE YOUR ORDER FOR WAYBILL NOW!


Contact,
Smartcell global services
081-350-31951
WHATSAPP::: https:///2348170385620

Re: Solar Energy, A Complement To FTA by simydan(m): 8:18am On Nov 30, 2019
mahkanjuh:

Thanks for this wonderful answer bro, but you didn't drop your contact.


Sorry about that.
This is also my WhatsApp contact: 0813-4608-560.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 11:09am On Nov 30, 2019
kiekie1:
THE BLACK FRIDAY D-DAY IS HERE! DONT MISS THIS GOLDEN OPPORTUNITY!!!


JUST 1 DAY FLASH SALES >> ITS A BLACK FRIDAY SALES !!

1) Ultron made in Korea 200a battery ... 100,000

2) Aspert 1.2kva inverter ... 50,000

3) Schneider 1.5kva inverter .. 60,000

4) USA Trojan 225a flooded battery ... 140,000

5) USA Trojan 205a AGM battery ... 150,000

6) TBB 4000w inverter ...155,000

7) Schneider sw 4048 inverter ...450,000

8 ) Monbat 200a battery ... 116,000

cool Schneider sw 8548 inverter ...999,000

DON'T MISS THIS GOLDEN OPPORTUNITY!


NOTE: If seriously interested in Black Friday sales opportunity for unit purchase of Trojan, Ultron , Monbat, axpert Ms,Schneider & tbb inverters.. feel free to contact me!


Contact,
Smartcell global services
081-350-31951
WHATSAPP::: https:///2348170385620

Thanks to all who patronized us yesterday & still calling for more order ! I also wish to inform y'al about the modest idle consumption of our South Korean TBB inverter as seen in datasheet below smiley.. Quite interesting as 4000w 48v idle state is 62 watts , and eco mode or power saving mode is 15 watts ! If you're on a budget bit below 240-300k , simply call me for this 5kva pure sinewave inverter !!!


Contact,
Smartcell global services
081-350-31951
WHATSAPP::: https:///2348170385620

1 Like

Re: Solar Energy, A Complement To FTA by Namzy(m): 2:05pm On Nov 30, 2019
kiekie1:
PROMO/FLASH SALES! ALL BRAND NEW WITH WARRANTY!!

1) Axpert 1.2kva 12v pure sinewave lcd inverter ..50000

2) Schneider 1.5kva 24v Solar/hybrid pure sinewave inverter ... 71,000

3) Axpert 3kva 24v solar/hybrid pure sinewave lcd wall mount inverter with inbuilt 80a total charge current .... 110,000

YOU CAN PICK UP IF BASED IN LAGOS OR SIMPLY PLACE YOUR ORDER FOR WAYBILL NOW!


Contact,
Smartcell global services
081-350-31951
WHATSAPP::: https:///2348170385620
Are you sure about the 80a total amp For the Axpert 3kva. I thought Its 55A. 30a from utility and 25a from PV
Re: Solar Energy, A Complement To FTA by mahkanjuh: 3:50pm On Nov 30, 2019
simydan:



Sorry about that.
This is also my WhatsApp contact: 0813-4608-560.
I appreciate you big time, I have sent you message on WhatsApp
Re: Solar Energy, A Complement To FTA by tchijioke: 6:20pm On Nov 30, 2019
eltolu:
Hello All,

Is it possible to connect the AC output of an inverter (5KVA) to the AC input of a second inverter (1.5KVA)? Planning to do this to charge a second battery bank that does not have solar attached to it. Also, the second inverter and battery bank will power other isolated equipment.

What do you experts recommend?

Its possible... Your major concern should be the capacity of your PV...ensure your PV output is enough to handle the additional load the 1.5kva inverter would require to charge the additional battery bank...
Personally I have similar setup running without issues.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 7:20pm On Nov 30, 2019
Namzy:

Are you sure about the 80a total amp For the Axpert 3kva. I thought Its 55A. 30a from utility and 25a from PV

Yes as stated "combined total" ! Solar 50a , AC 20/30a as written in system manual .. Guess you compared with gennex 3kva 24v with 600w solar Max as seen in datasheet snapshot below but this 3kva model is approx 1500w max solar ! Cheer's

Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 9:29pm On Nov 30, 2019
Please I need help on how best to deal with this panel - I need to fix new cables on 3 out of 9 panels.

These were Flames panels from my old system that I sent to family house to for their use but the installers did a shoddy job twisting wires together with not enough contact area, in each set of 3 panels in series the outgoing negative cable (that would go to PV combiner box or CC) is burnt all the way.

The things I have considered are to purchase 6mm stranded cable and;

1) Desolder the old and solder on the new 6mm cables with MC4 at the other end

2) Unscrew the red highlighted screw, crimp on eyelet terminals to the 6mm cable and use that point as the new connection source - I have concerns about long term stability or the screw wearing lose under strain or high currents or possibly bypassing the diodes (didn't work out the physics of this)

3) Acquire a spot welder and use this to attach new cables to the panels.

I want to make an easy and durable connection - I would appreciate advise from any who have walked this path before or have expertise.

Someone I spoke to blamed the 'Alaba' Flames panels but I still have 12 units from the same batch (3 years +) on my roof and no issues - I am convinced the issue was how the connections were poorly/lazily made as the cables burnt from the connection point all the way to the panel junction box.

Re: Solar Energy, A Complement To FTA by earthrealm(m): 6:41am On Dec 01, 2019
eltolu:
Hello All,

Is it possible to connect the AC output of an inverter (5KVA) to the AC input of a second inverter (1.5KVA)? Planning to do this to charge a second battery bank that does not have solar attached to it. Also, the second inverter and battery bank will power other isolated equipment.

What do you experts recommend?


its possibble, however, i think a standalone smart charger would be better/consume less energy to charge the 2nd batt bank.
also, have you considered simply running ac cables to power the load you have on the 2nd inverter
Re: Solar Energy, A Complement To FTA by eleojo23: 7:01am On Dec 01, 2019
Witches are viewing this thread this morning...hmmm...I hope we are safe shocked lipsrsealed

1 Like

Re: Solar Energy, A Complement To FTA by ceaser: 9:11am On Dec 01, 2019
eleojo23:
Witches are viewing this thread this morning...hmmm...I hope we are safe shocked lipsrsealed

grin
Re: Solar Energy, A Complement To FTA by AshipaEk0: 10:45am On Dec 01, 2019
Hello sirs.

Please what capacity of standalone charger will one need to charge 4 units of 200 Amps 12 Volts batteries?
Re: Solar Energy, A Complement To FTA by eleojo23: 11:38am On Dec 01, 2019
AshipaEk0:
Hello sirs.

Please what capacity of standalone charger will one need to charge 4 units of 200 Amps 12 Volts batteries?

A 40amps charger should get the batteries full within 10hrs if you only discharge the batteries to 50% at each use.

If you can get a 50amps charger, the charging time can further be reduced to 8hrs at 50% DOD
Re: Solar Energy, A Complement To FTA by Witches: 1:19pm On Dec 01, 2019
[quote author=ceaser post=84518546]

���
Re: Solar Energy, A Complement To FTA by Witches: 1:20pm On Dec 01, 2019
ceaser:


grin

��
Re: Solar Energy, A Complement To FTA by Witches: 1:27pm On Dec 01, 2019
eleojo23:
Witches are viewing this thread this morning...hmmm...I hope we are safe shocked lipsrsealed


Eleojo omaiye mi , aaaigbo , you're safe
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 3:23pm On Dec 01, 2019
NiyiOmoIyunade:
Please I need help on how best to deal with this panel - I need to fix new cables on 3 out of 9 panels.

These were Flames panels from my old system that I sent to family house to for their use but the installers did a shoddy job twisting wires together with not enough contact area, in each set of 3 panels in series the outgoing negative cable (that would go to PV combiner box or CC) is burnt all the way.

The things I have considered are to purchase 6mm stranded cable and;

1) Desolder the old and solder on the new 6mm cables with MC4 at the other end

2) Unscrew the red highlighted screw, crimp on eyelet terminals to the 6mm cable and use that point as the new connection source - I have concerns about long term stability or the screw wearing lose under strain or high currents or possibly bypassing the diodes (didn't work out the physics of this)

3) Acquire a spot welder and use this to attach new cables to the panels.

I want to make an easy and durable connection - I would appreciate advise from any who have walked this path before or have expertise.

Someone I spoke to blamed the 'Alaba' Flames panels but I still have 12 units from the same batch (3 years +) on my roof and no issues - I am convinced the issue was how the connections were poorly/lazily made as the cables burnt from the connection point all the way to the panel junction box.


Option 1 is better. I had a similar experience and I had to use option 2 because it was a smaller setup and an emergency fix.
Re: Solar Energy, A Complement To FTA by ojeysky(m): 5:54pm On Dec 01, 2019
babaegun:




I use the 1.5HP GenCool. Its great. I have a Power Meter attached to it. I noticed if you put it in the GenMode, It will peak at 850Watts or slightly less. It is great. You can give it a try.

Meanwhile, on your emoncms dashboard I see you have the battery AH log, can you tell me how you got to set that up? I run emoncms as well but have been trying to get the AH on my dash as well.
Re: Solar Energy, A Complement To FTA by desiji: 7:39pm On Dec 01, 2019

Re: Solar Energy, A Complement To FTA by AshipaEk0: 8:29pm On Dec 01, 2019
eleojo23:


A 40amps charger should get the batteries full within 10hrs if you only discharge the batteries to 50% at each use.

If you can get a 50amps charger, the charging time can further be reduced to 8hrs at 50% DOD

Thank you
Re: Solar Energy, A Complement To FTA by nonoski: 10:26pm On Dec 01, 2019
What ever you do
Neva ever buy a Luminous Battery
Neva

Thank me later embarassed embarassed

2 Likes

Re: Solar Energy, A Complement To FTA by mctfopt: 5:08am On Dec 02, 2019
nonoski:
What ever you do
Neva ever buy a Luminous Battery
Neva

Thank me later embarassed embarassed

We will appreciate it if you can share your unpleasant experience with the battery.

(1) (2) (3) ... (613) (614) (615) (616) (617) (618) (619) ... (1691) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: kiekie1(m)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 53
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.