Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 11:39am On Jan 09, 2020
Topmost11:
Hello house. How good are GBM batteries?
Very good batteries sir, and they’re long lasting.
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 11:45am On Jan 09, 2020
270watts Flames solar panel is available, #29 000. Contact us on - 08168986461

3 Likes

Re: Solar Energy, A Complement To FTA by olopan(m): 12:21pm On Jan 09, 2020
Yes, but went to Lagos to get a few items for a site maintenance.

oliyeniun:
Thank you sir. Are u in Ilorin?

1 Like

Re: Solar Energy, A Complement To FTA by Topmost11(m): 12:30pm On Jan 09, 2020
olopan:
Is the CC a PWM? Or MPPT
And where are you based at in the country?



4×150watts panels(two more to be added by feb ending) in parallel
25meters×6mm cable
12v 900vac inverter
60a mppt CC
200ah battery
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 12:56pm On Jan 09, 2020
200amphs, 12volts ZEDIX battery available, #75 000. Contact us on 08168986461

Re: Solar Energy, A Complement To FTA by olopan(m): 2:26pm On Jan 09, 2020
okay!
with the 6mm cable, you will loss some power along that long stretch of length.

so here lies the Dilemma, 2s2p or 2s3p for the future is the best and most sweet spot you should opt for, but with the cable not being so large coupled with long distance.
BUT
because your cable is 6mm i will suggest a 3s2p so you will not loss much power.

One other thing i notice is that, you will most likely oversize your array by 15% or 115% which is great but with a down size of overcharging your 200Ah battery. .... you don't want your sweet battery to start releasing Hydrogen gas...... No.

if need be that you will really use the PV upgrade, then the 3s2p option will be best advice for reason stated above,
* As it will not allow the current to overshoot too quickly to overcharge your battery.

These are my own POV.

Topmost11:




4×150watts panels(two more to be added by feb ending) in parallel
25meters×6mm cable
12v 900vac inverter
60a mppt CC
200ah battery
Re: Solar Energy, A Complement To FTA by Topmost11(m): 5:38pm On Jan 09, 2020
olopan:
okay!
with the 6mm cable, you will loss some power along that long stretch of length.

so here lies the Dilemma, 2s2p or 2s3p for the future is the best and most sweet spot you should opt for, but with the cable not being so large coupled with long distance.
BUT
because your cable is 6mm i will suggest a 3s2p so you will not loss much power.

One other thing i notice is that, you will most likely oversize your array by 15% or 115% which is great but with a down size of overcharging your 200Ah battery. .... you don't want your sweet battery to start releasing Hydrogen gas...... No.

if need be that you will really use the PV upgrade, then the 3s2p option will be best advice for reason stated above,
* As it will not allow the current to overshoot too quickly to overcharge your battery.

These are my own POV.


Release hydrogen gas ke? That one is something I don't want o. That battery was "cooperative loan" o.

One thing I have thought of is this:
let things be for now and revert to the pwm cc. Continue using it.


I will as soon as possible change my inverter to 24v. Then buy 16mm cable and two or four 250watts panels. Install it with the 60a mppt cc and new 2×100ah batteries

And the mppt cc can't be logged; by the time I get home, it will be sundown and it would have reverted to zero so I can't record harvest again
Re: Solar Energy, A Complement To FTA by ojeysky(m): 5:51pm On Jan 09, 2020
Valto:
thanks. had my double door LG fridge repaired by changing internal condenser to an outside one. power consumption jumps down from the previous 195w to 110wcheesy

Cool and how is the performance after that and does the power reduce over time? There was a time my 219t freezer developed a fault and stopped working, I called a technician to fix it (or so I thought) unfortunately since then, the freezer has been on high freezing consuming over 250w. I just resolved to utilize my fridge more.
Re: Solar Energy, A Complement To FTA by Valto(m): 10:45pm On Jan 09, 2020
ojeysky:


Cool and how is the performance after that and does the power reduce over time? There was a time my 219t freezer developed a fault and stopped working, I called a technician to fix it (or so I thought) unfortunately since then, the freezer has been on high freezing consuming over 250w. I just resolved to utilize my fridge more.
the lowest i have seen is 134w(inclusive 28w fridge fan ), am yet to test it for 6 straight hrs. but the performance is encouraging. the sound and operating temperature is now cooler. it blocks pure water in the freezer compartment in 2hrs. i have another BEKO double door fridge, it draws 115w(inclusive 28w fan) it blocks pure water in 1hr30mins.
Re: Solar Energy, A Complement To FTA by Topmost11(m): 2:16am On Jan 10, 2020
Valto:
the lowest i have seen is 134w(inclusive 28w fridge fan ), am yet to test it for 6 straight hrs. but the performance is encouraging. the sound and operating temperature is now cooler. it blocks pure water in the freezer compartment in 2hrs. i have another BEKO double door fridge, it draws 115w(inclusive 28w fan) it blocks pure water in 1hr30mins.

Contact of this your technician, and where is he based?
Re: Solar Energy, A Complement To FTA by Topmost11(m): 2:35am On Jan 10, 2020
Anyone with 10mm and 16mm dual core cable for sale?
Re: Solar Energy, A Complement To FTA by Valto(m): 6:57am On Jan 10, 2020
Topmost11:


Contact of this your technician, and where is he based?
ok. everything depends on the type of compressor. the rated watts for the LG was 165w,but maybe the inbuilt internal condenser was bad, hence it was getting too hot and was drawing 230watts before(inclusive 30W external fan) he only disconnected the internal one put his external one(pix) and everything become cool.. my location is yenagoa bayelsa state.

1 Share

Re: Solar Energy, A Complement To FTA by ceaser: 7:17am On Jan 10, 2020
Here

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 7:38am On Jan 10, 2020
Topmost11:
Anyone with 10mm and 16mm dual core cable for sale?
Yeah sir, I’m base in Lagos.
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 7:43am On Jan 10, 2020
250amphs, 12volts GREEN POWER BATTERY available, #85 000 with 1yr warranty. Contact us on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 7:46am On Jan 10, 2020
60amphs diamond charge controller available, #17000. Contact us on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 7:49am On Jan 10, 2020
60amphs solar street light available, #75000. Contact us on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 7:52am On Jan 10, 2020
5kva, 48volts hybrid MUST INVERTER with inbuilt charge controller is available, #270000. Contact us on 08168986461

1 Like

Re: Solar Energy, A Complement To FTA by saint2ace(m): 10:49am On Jan 10, 2020
ceaser:
Here

Thanks ceaser ur post was quite insightful and informative, sorry about the ban thing; we've all gotten used to it. Thanks once again and i'll keep you updated how mine works. Cheers
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 12:01pm On Jan 10, 2020
325watt felicity solar panel available, #39000. Contact us on 08168986461

2 Likes 1 Share

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 3:38pm On Jan 10, 2020
180amphs, 12volts GBM slim battery available, #65000. Contact us on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 3:41pm On Jan 10, 2020
210amphs, 12volts GBM battery available, #75000. Contact us on 08168986461

Re: Solar Energy, A Complement To FTA by remizvxcq(m): 3:42pm On Jan 10, 2020
Topmost11:


??
I was in a bank the other day to market these high-calibre ESS.
The guy in charge said that they already have back-up generator and each computer station has its own UPS.
As he was saying this, PHCN/NEPA took light.
The banking hall went dark, in mid day, while the sun was shining hot outside.
For a few minutes, everybody stood still, while the UPS stations stated screwing that annoying alarm sound.
Then a mighty roar as the back up generator started up. And died, A second roar as a bigger back-up for the first backup kicked into life.
Consuming litres of diesel, and belching thick toxic fumes into the surroundings.
Within a half-hour, PHCN/NEPA was back.

All the noisy beep, beep, beeeeeeeeeeeeeeeeeeeeeep, nuisance smells, poisonous fumes, embarrassment of stop-work, danger of inflammable fossil fuels in close proximity to confined premises, lost profits due to maintenance and repair costs of over-large generators, all that, could be better managed at lower costs, with a LiFePO4 ESS.
Get in touch for an energy audit.

1 Like

Re: Solar Energy, A Complement To FTA by Topmost11(m): 4:10pm On Jan 10, 2020
justcallmenuel:

Yeah sir, I’m base in Lagos.

Price sir?
Re: Solar Energy, A Complement To FTA by Topmost11(m): 4:19pm On Jan 10, 2020
Aside from space occupied, what are merits of bigger(250,300,325, etc) panels over small panels(100,150,180etc)
Re: Solar Energy, A Complement To FTA by olopan(m): 6:17pm On Jan 10, 2020
care to please give more info?
remizvxcq:

I was in a bank the other day to market these high-calibre ESS.
The guy in charge said that they already have back-up generator and each computer station has its own UPS.
As he was saying this, PHCN/NEPA took light.
The banking hall went dark, in mid day, while the sun was shining hot outside.
For a few minutes, everybody stood still, while the UPS stations stated screwing that annoying alarm sound.
Then a mighty roar as the back up generator started up. And died, A second roar as a bigger back-up for the first backup kicked into life.
Consuming litres of diesel, and belching thick toxic fumes into the surroundings.
Within a half-hour, PHCN/NEPA was back.

All the noisy beep, beep, beeeeeeeeeeeeeeeeeeeeeep, nuisance smells, poisonous fumes, embarrassment of stop-work, danger of inflammable fossil fuels in close proximity to confined premises, lost profits due to maintenance and repair costs of over-large generators, all that, could be better managed at lower costs, with a LiFePO4 ESS.
Get in touch for an energy audit.

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 6:33pm On Jan 10, 2020
Topmost11:


Price sir?
#950 per metre sir.
Re: Solar Energy, A Complement To FTA by Trippledots(m): 8:53pm On Jan 10, 2020
justcallmenuel:

Very good batteries sir, and they’re long lasting.

I heard crocs batteries in this category are best..
Re: Solar Energy, A Complement To FTA by Xpac123kid: 11:41pm On Jan 10, 2020
Good evening house, I want to ask a question. Is it possible to connect 3 12volts 200ah battery to a 24volts inverter. The batteries will also be charged by a 24volts charge controller
Re: Solar Energy, A Complement To FTA by PrinceCEE(m): 1:57am On Jan 11, 2020
Hello!

Please I need candid advice on the best choice and also the the budget from the inverter to the installation cost.

I need a setup that'd last me for the whole day, given the power consumptions.

1. 4 laptops
2. One 32inch led tv
3. Three ceiling fans.
4. 5 energy saving bulbs
5. Home theatre
6. AC
7. Mid size refrigerator

I would want both the inverter and solar together. So what's gonna be the likely configuration and budget?
Re: Solar Energy, A Complement To FTA by ceaser: 4:57am On Jan 11, 2020
Xpac123kid:
Good evening house, I want to ask a question. Is it possible to connect 3 12volts 200ah battery to a 24volts inverter. The batteries will also be charged by a 24volts charge controller

No sir. It's not allowed.

In simple terms:

24v inverter requires 24volts input.

Your batteries (3 in number) can either give you 12v in parallel or 36v in series, both of which are off the 24v target.

To achieve a target for your 24v inverter, you either get to use only two out of your three 12v batteries connected in series to get 24v total OR you get a fourth battery to configure a 2s2p bank (still 24v nominal but with higher capacity)

Please in using your batteries, do not mix old batteries with new ones.

4 Likes

Re: Solar Energy, A Complement To FTA by ceaser: 5:06am On Jan 11, 2020
justcallmenuel:
250amphs, 12volts GREEN POWER BATTERY available, #85 000 with 1yr warranty. Contact us on 08168986461

Na wa o.

These batteries heh, can you guarantee impressive performance from 'em?

(1) (2) (3) ... (641) (642) (643) (644) (645) (646) (647) ... (1747) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: EduTechTainMent, Hero2t and 5 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 43
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.