Re: Solar Energy, A Complement To FTA by Saipro(m): 1:01pm On Nov 11, 2018
DMerciful:
The reading on the CC is quite strange as panel current is higher than battery current, unless the pictures were not taken at the same time. My recommendation will be to get an mppt cc and a professional installer. See my signature for whatsapp contact
His system is small enough for the money spent on a new CC to be better utilised by a larger PV array. Or so me thinks (below 1kWp, MPPT barely outperforms PWM, assuming the typical 24VDC nominal, short cable runs, etc).

roolnaado:
Hi, I'm a newbie, and I don't know these ratings. I am doubting the installer that's why I want ask for more info here. It's a PWM controller. I will tell him to do a parallel configuration.

Thanks
Understood. If the panels are accessible, those info should be pasted on the back. Your installer cum supplier should otherwise have those figures.

efuro:

I agree with you to the extent that the 100w pv are truly 24v as his 24v-30a pwm will receive a max amps up to 20a on a good day where no other charging source exist as pointed out by dmerciful.
The post came after mine. I had no way of telling, at least not from the info previously supplied.
Re: Solar Energy, A Complement To FTA by Saipro(m): 1:52pm On Nov 11, 2018
There's a wrong way to do the right thing.

A few days ago early in the morning, I topped up my 12V FLA batteries before charging. First wrong thing (top up after charging unless cells are exposed). I was in a rush and miscalculated thus topping each cell with 300mLs instead of 200mLs. I ran out of distilled water on the 3rd battery. I had a half battery and another unfilled battery to go. No problem, I would distil water the next day to make up. Didn't happen as I got really busy. Minimally unbalanced rack. Easy fix.

A day more and I got back to it. Despite knowing the rote, I did the second faux pas. I topped up the other cells (again, before charging) and proceeded to do a straight away equalisation charge (without first completing absorb). Impatience is definitely not a virtue. From batteries 0.01V in variation, I arrived at a bank with 0.13V variation. The beginning of the end. Enter panic mode.

Waited one agonising day in order not to boil the batteries to death. At dawn, whipped out my standalone 12V charger, DC clamp meter and babysat the bank on Saturday. Did another equalisation after completing absorb, moving the standalone charger to hasten the lowest (last topped up battery) catching up with the others. Literally watched it go to float.
Bank temperature 34.2oC
Battery voltages
- 13.07V
- 13.07V
- 13.06V
- 13.07V

Hourly review for the rest of the day. Checked this afternoon and everything is as measured the previous day.

Cardiac arrest averted. All is well. Time for some isi-ewu and Maltina.

7 Likes

Re: Solar Energy, A Complement To FTA by ojeysky(m): 4:36pm On Nov 11, 2018
earthrealm:


Sry..error.
Its 80v to 280v

Hmm...I don't know of any 10kva servo from prag that is 80v to 280v. Do you have pointers?

Regards
PS: Am enjoying my 10kva desktop A&E so far but will be good to know.
Re: Solar Energy, A Complement To FTA by efuro(m): 5:35pm On Nov 11, 2018
love story of off grid Solar addict. I dey feel you bros, sometimes I envy fla users.
I hope you have battery equaliser.?.

Saipro:
There's a wrong way to do the right thing.

A few days ago early in the morning, I topped up my 12V FLA batteries before charging. First wrong thing (top up after charging unless cells are exposed). I was in a rush and miscalculated thus topping each cell with 300mLs instead of 200mLs. I ran out of distilled water on the 3rd battery. I had a half battery and another unfilled battery to go. No problem, I would distil water the next day to make up. Didn't happen as I got really busy. Minimally unbalanced rack. Easy fix.

A day more and I got back to it. Despite knowing the rote, I did the second faux pas. I topped up the other cells (again, before charging) and proceeded to do a straight away equalisation charge (without first completing absorb). Impatience is definitely not a virtue. From batteries 0.01V in variation, I arrived at a bank with 0.13V variation. The beginning of the end. Enter panic mode.

Waited one agonising day in order not to boil the batteries to death. At dawn, whipped out my standalone 12V charger, DC clamp meter and babysat the bank on Saturday. Did another equalisation after completing absorb, moving the standalone charger to hasten the lowest (last topped up battery) catching up with the others. Literally watched it go to float.
Bank temperature 34.2oC
Battery voltages
- 13.07V
- 13.07V
- 13.06V
- 13.07V

Hourly review for the rest of the day. Checked this afternoon and everything is as measured the previous day.

Cardiac arrest averted. All is well. Time for some isi-ewu and Maltina.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:31am On Nov 12, 2018
DISCOUNTED PRICES - NUM 1 ONLINE STORE!!!

USA Magnum inverter 4124 ..... 930,000
USA Deka 210a battery .............190,000

Felicity 200a battery ...................90,000
Motoma 200a battery ................115,000
Cinemax 200a battery ................115,000
Cinemax 210a battery ................120,000

Morningstar 60a mppt ...............215,000
Morningstar 45a mppt................190,000
Tsm2 display ...............................60,000
Schneider 60a mppt ....................240,000

Battery equaliser 6-48v... 35,000 30,000

Epsolar Epever solar charge controllers
MT50 display ..................................15,000
Epever 12-24v 30a mppt ................50,000
Epever 12-24v 40a 4210N mppt ...........65,000
Epever 12-48v 60a itracer mppt....135,000

Epsolar PWM
30a 12-24v VS3024A .........30,000
45a 12-48v VS4548BN .......70,000
60a 12-48v VS6048AU .......80,000

Fangpusun MPPT
30a 12-24v .............................55,000
60a 12-48v mppt TR victron clone series ..125,000
60a 12-48v outback clone with display.......145,000
80a 12-48v mppt outback clone .................155,000

Must Power Star Light inverters with LCD display
1000w 12v=92k
1500w 12v=102k
3kva(2000w)-12v=115,000
4kva(3000w)-24v=155,000
5kva(4000w)-24/48=240,000
6kva(5000w)-24/48= 260,000
7.5kva(6000w)-24/48= 280,000
SS Power inverters with LCD display
1.5kva 12/24v= 75,000
2kva 12/24v= 85,000
3.5kva 24v= 130,000
5kva 24/48v= 160,000
7.5kva 48v= 280,000
10kva 48v= 340,000
10kva 48/96v (standing)= 350,000

Keye 1.2kva/12v(without charger) 13,000
Keye 2.2kva/12v(without Charger) 18,000
Keye pure sinewave series
Keye 800va/12v 45,000
Keye 1.2kva/12v 55,000
Keye 3.5kva/24v 150,000
Keye 3.5kva/48v 150,000
Keye 5kva/24v 170,000
Keye 5kva/48v 170,000
Keye 7.5kva/48v 350,000
Keye 10kva/48v 370,000
Fangpusun 80a MPPT @ 155k
EP Solar 12/24/36/48v 60a mppt(i tracer) solar charge controller @ 135k
EP Solar 12/24v 40a MPPT solar charge controller @ 65k
Trojan 12v 200a J200re USA flooded batteries @ 129k...(limited quantity in stock)
Trojan 12v 205a agm batteries ... 164k
Trojan 6v 315a agm battery.... 155k
Trojan 6v 375a agm battery .... Arriving soon
USA Deka 12v 210a .......190k
USA Mnspd 300 DC / AC ..... 50k
Schneider DC SPD ..........30k
AC/DC true RMS Clamp meters
UNI-T 203 ...N 20k
Suoer intelligent-automatic 30A 12V Battery Charger (MA-1230A) .... N 19k
DC display meters 0-30v...N 1600
DC display meters 0-120v..N 2200
ZHC Battery equalizer 12/24/36/48 volts..... 24k
Quanta Amaron 12v 200a vrla battery @ ... N127,000
Long 200a AGM batteries .... N120,000
Long 150a slim AGM battery..93,000
Long 100a AGM battery ........ 65,000
Long 100a carbon battery ..... 75,000
Superceed Batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Maximum power batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Double tech batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Network batteries
12v 110ah= 50,000
12v 180ah= 70,000
12v 210ah= 90,000
12v 250ah= 115,000
Flames 300w mono .... 47k
Watts meter "kill-a-watt meter" ....9k
Yachi solar panels ;
150w mono panels........@35k
260w mono panels.......@48k "limited stock"
310w mono panels........@59k "limited stock"
DISCOUNTED PRICES ! CALL US NOW !!
Magnum 4348 USA inverter ....@900k
Victron multiplus 3kva 48v .....@600k
Schneider connect 2524..........@550k
Growatts SPF3000 plus hybrid/solar inverter...@290k
Growatts SPF 5000 hybrid/solar inverter... @320k
Canadian 340w mono solar panel"Korean cells" .... Offloading
Canadian 300w mono solar panel... 62,000
Canadian 330w mono solar panel.....@66,000 bulk price
Sunshine solar modules :
130w poly 23000
250w poly 39000
300w Mono 52,000
Quality chinese panels best price:
100w poly 18500
100w mono 19500
150w poly 23000
200w mono 33000
260w poly 35500
260w mono 39000
320w poly 45500

Mercury Industrial Stabilizer available now
10kva Single phase 100,000
15kva Single phase 157,000
20kva Single phase 195,000
30kva Single phase 300,000
15kva 3Phase in/out 195,000
30kva 3Phase in/out 320,000
50kva 3Phase in/out 830,000

Mercury Spirit Plus Hybrid Inverters are available now
2000 Spirit 2kva 120,000
2001 Spirit Plus 2kva 135,000
3001 Spirit Plus 3kva 165,000
5001 Spirit Plus 5kva 220,000
3kva Soho Inverter 185,000
5kva Soho Inverter 265,000
7.5kva Soho Inverter 300,000

BATTERIES
Mercury 1.2kva Inverter 40,000
Mercury 2.4kva Inverter 45,000
Mercury 200ah GEL battery 140,000
Mercury 200ah AGM battery 100,000
Mercury 100ah AGM battery 55,500

LUMINOUS BATTERIES:
Luminous 150AH/12V SMF .... 92k
Luminous Blue 200AH/12V .....125k
Luminous tubular 220AH/12V..105k

LUMINOUS PURE SINEWAVE INVERTERS:
Luminous 850va/12v hybrid...52k
Luminous 875va/12v Eco.......37k
Luminous 1.5kva/24v Eco.......57k
Luminous 1.5kva/24v Zelio.....75k
Luminous 1.5kva/24v hybrid...80k
Luminous 3.5kva/48v Cruise..180k
Luminous 5kva/96v Cruise ....400k
Luminous 7.5kva/120v Cruise..500k
Luminous 10kva/180v ...........660k
Luminous 15kva/240v.............1m
Luminous 20kva/360v............ ----

BEST PRICES YOU CAN GET ON PRAG PRODUCTS !!!

Prag inverter 1kva 12v ......N65,000
Prag √√√√√ 1.2kva 12v....N70,000
Prag √√√√√ 2kva 24v.......N
Prag √√√√√ 1.5kva 24v....N98,000
Prag √√√√√ 2.5kva 24v....N112,000
Prag √√√√√ 1.5kva 24v....N96_000

Prag Solar inverter 1.5kva 24v....N120,000
Prag inverter 3kva 24v ....N145,000
Prag inverter 5kva 48v...N250,000
Prag inverter 7.5kva 120v ....N410,000
Prag inverter 10kva 180v....N480,000

Prag 4kva 24v wall H ......N245,000
Prag 6.5kva 48v wall H....N350,000


PRAG servo & relay stabilizers ;

-Prag 3kva relay B(95-280v)..N
-Prag 3kva relay E(95-280v)..N
-Prag 10kva servo ..N110,000
-Prag 10kva servo(130-250v)..N115,000
-Prag 12kva servo...N
-Prag 15kva relay(95-280v)...N110,000
-Prag 15kva servo(80-260v)..N220,000
-Prag 15kva servo(130-260v)..N190,000
-Prag 20kva servo (80-260v)..N310,000
-Prag 20kva servo(130-260v)...N230,000
-Prag 20kva relay Y..
-Prag 20kva servo(80-260v) ...N
-Prag 30kva servo(80-260v)...N400,000
-Prag 30kva servo(1300-260v)..N380,000

Protek 200L solar water heater... N215,000
With 30k , I can offer you a set of pro solar roof mounts to comfortably mount 4 units of 250 to 350w solar panel's including kits like ;
2 qty solar mount rail "4200mm" ,
4 qty rack end clamp,
6 qty mid clamp,
6 qty L feet with rubber & special screw....
Same goes to angle positioning solar kits;
- Adjustable front leg
- Adjustable rear leg
- Rail splice kit
- Grounding lug


WHATSAPP::: https:///send?phone=2348170385620

*AUTHORISED DEALER PRAGMATIC TECHNOLOGIES*
All our prag products comes with reliable warranty
*AUTHORIZED DEALER INDIAN INVERTERS / BATTERIES ... Luminous PRODUCTS*
All our products come with 1 year Warranty
*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty.
For best affordable prices contact,
The number 1 credible online store,
Smartcell Global Services,Lagos Nigeria.
Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!

2 Likes

Re: Solar Energy, A Complement To FTA by Dam5reey(m): 11:22pm On Nov 12, 2018
Oga Kiekie, Please open your own website..

You're now bigger than Nairaland, Even konga and Jumia combined no get your kind of stocks.. grin

9 Likes 1 Share

Re: Solar Energy, A Complement To FTA by Trippledots(m): 6:46am On Nov 13, 2018
kiekie1:
DISCOUNTED PRICES - NUM 1 ONLINE STORE!!!

USA Magnum inverter 4124 ..... 930,000
USA Deka 210a battery .............190,000

Felicity 200a battery ...................90,000
Motoma 200a battery ................115,000
Cinemax 200a battery ................115,000
Cinemax 210a battery ................120,000

Morningstar 60a mppt ...............215,000
Morningstar 45a mppt................190,000
Tsm2 display ...............................60,000
Schneider 60a mppt ....................240,000

Battery equaliser 6-48v... 35,000 30,000

Epsolar Epever solar charge controllers
MT50 display ..................................15,000
Epever 12-24v 30a mppt ................50,000
Epever 12-24v 40a 4210N mppt ...........65,000
Epever 12-48v 60a itracer mppt....135,000

Epsolar PWM
30a 12-24v VS3024A .........30,000
45a 12-48v VS4548BN .......70,000
60a 12-48v VS6048AU .......80,000

Fangpusun MPPT
30a 12-24v .............................55,000
60a 12-48v mppt TR victron clone series ..125,000
60a 12-48v outback clone with display.......145,000
80a 12-48v mppt outback clone .................155,000

Must Power Star Light inverters with LCD display
1000w 12v=92k
1500w 12v=102k
3kva(2000w)-12v=115,000
4kva(3000w)-24v=155,000
5kva(4000w)-24/48=240,000
6kva(5000w)-24/48= 260,000
7.5kva(6000w)-24/48= 280,000
SS Power inverters with LCD display
1.5kva 12/24v= 75,000
2kva 12/24v= 85,000
3.5kva 24v= 130,000
5kva 24/48v= 160,000
7.5kva 48v= 280,000
10kva 48v= 340,000
10kva 48/96v (standing)= 350,000

Keye 1.2kva/12v(without charger) 13,000
Keye 2.2kva/12v(without Charger) 18,000
Keye pure sinewave series
Keye 800va/12v 45,000
Keye 1.2kva/12v 55,000
Keye 3.5kva/24v 150,000
Keye 3.5kva/48v 150,000
Keye 5kva/24v 170,000
Keye 5kva/48v 170,000
Keye 7.5kva/48v 350,000
Keye 10kva/48v 370,000
Fangpusun 80a MPPT @ 155k
EP Solar 12/24/36/48v 60a mppt(i tracer) solar charge controller @ 135k
EP Solar 12/24v 40a MPPT solar charge controller @ 65k
Trojan 12v 200a J200re USA flooded batteries @ 129k...(limited quantity in stock)
Trojan 12v 205a agm batteries ... 164k
Trojan 6v 315a agm battery.... 155k
Trojan 6v 375a agm battery .... Arriving soon
USA Deka 12v 210a .......190k
USA Mnspd 300 DC / AC ..... 50k
Schneider DC SPD ..........30k
AC/DC true RMS Clamp meters
UNI-T 203 ...N 20k
Suoer intelligent-automatic 30A 12V Battery Charger (MA-1230A) .... N 19k
DC display meters 0-30v...N 1600
DC display meters 0-120v..N 2200
ZHC Battery equalizer 12/24/36/48 volts..... 24k
Quanta Amaron 12v 200a vrla battery @ ... N127,000
Long 200a AGM batteries .... N120,000
Long 150a slim AGM battery..93,000
Long 100a AGM battery ........ 65,000
Long 100a carbon battery ..... 75,000
Superceed Batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Maximum power batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Double tech batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Network batteries
12v 110ah= 50,000
12v 180ah= 70,000
12v 210ah= 90,000
12v 250ah= 115,000
Flames 300w mono .... 47k
Watts meter "kill-a-watt meter" ....9k
Yachi solar panels ;
150w mono panels........@35k
260w mono panels.......@48k "limited stock"
310w mono panels........@59k "limited stock"
DISCOUNTED PRICES ! CALL US NOW !!
Magnum 4348 USA inverter ....@900k
Victron multiplus 3kva 48v .....@600k
Schneider connect 2524..........@550k
Growatts SPF3000 plus hybrid/solar inverter...@290k
Growatts SPF 5000 hybrid/solar inverter... @320k
Canadian 340w mono solar panel"Korean cells" .... Offloading
Canadian 300w mono solar panel... 62,000
Canadian 330w mono solar panel.....@66,000 bulk price
Sunshine solar modules :
130w poly 23000
250w poly 39000
300w Mono 52,000
Quality chinese panels best price:
100w poly 18500
100w mono 19500
150w poly 23000
200w mono 33000
260w poly 35500
260w mono 39000
320w poly 45500

Mercury Industrial Stabilizer available now
10kva Single phase 100,000
15kva Single phase 157,000
20kva Single phase 195,000
30kva Single phase 300,000
15kva 3Phase in/out 195,000
30kva 3Phase in/out 320,000
50kva 3Phase in/out 830,000

Mercury Spirit Plus Hybrid Inverters are available now
2000 Spirit 2kva 120,000
2001 Spirit Plus 2kva 135,000
3001 Spirit Plus 3kva 165,000
5001 Spirit Plus 5kva 220,000
3kva Soho Inverter 185,000
5kva Soho Inverter 265,000
7.5kva Soho Inverter 300,000

BATTERIES
Mercury 1.2kva Inverter 40,000
Mercury 2.4kva Inverter 45,000
Mercury 200ah GEL battery 140,000
Mercury 200ah AGM battery 100,000
Mercury 100ah AGM battery 55,500

LUMINOUS BATTERIES:
Luminous 150AH/12V SMF .... 92k
Luminous Blue 200AH/12V .....125k
Luminous tubular 220AH/12V..105k

LUMINOUS PURE SINEWAVE INVERTERS:
Luminous 850va/12v hybrid...52k
Luminous 875va/12v Eco.......37k
Luminous 1.5kva/24v Eco.......57k
Luminous 1.5kva/24v Zelio.....75k
Luminous 1.5kva/24v hybrid...80k
Luminous 3.5kva/48v Cruise..180k
Luminous 5kva/96v Cruise ....400k
Luminous 7.5kva/120v Cruise..500k
Luminous 10kva/180v ...........660k
Luminous 15kva/240v.............1m
Luminous 20kva/360v............ ----

BEST PRICES YOU CAN GET ON PRAG PRODUCTS !!!

Prag inverter 1kva 12v ......N65,000
Prag √√√√√ 1.2kva 12v....N70,000
Prag √√√√√ 2kva 24v.......N
Prag √√√√√ 1.5kva 24v....N98,000
Prag √√√√√ 2.5kva 24v....N112,000
Prag √√√√√ 1.5kva 24v....N96_000

Prag Solar inverter 1.5kva 24v....N120,000
Prag inverter 3kva 24v ....N145,000
Prag inverter 5kva 48v...N250,000
Prag inverter 7.5kva 120v ....N410,000
Prag inverter 10kva 180v....N480,000

Prag 4kva 24v wall H ......N245,000
Prag 6.5kva 48v wall H....N350,000


PRAG servo & relay stabilizers ;

-Prag 3kva relay B(95-280v)..N
-Prag 3kva relay E(95-280v)..N
-Prag 10kva servo ..N110,000
-Prag 10kva servo(130-250v)..N115,000
-Prag 12kva servo...N
-Prag 15kva relay(95-280v)...N110,000
-Prag 15kva servo(80-260v)..N220,000
-Prag 15kva servo(130-260v)..N190,000
-Prag 20kva servo (80-260v)..N310,000
-Prag 20kva servo(130-260v)...N230,000
-Prag 20kva relay Y..
-Prag 20kva servo(80-260v) ...N
-Prag 30kva servo(80-260v)...N400,000
-Prag 30kva servo(1300-260v)..N380,000

Protek 200L solar water heater... N215,000
With 30k , I can offer you a set of pro solar roof mounts to comfortably mount 4 units of 250 to 350w solar panel's including kits like ;
2 qty solar mount rail "4200mm" ,
4 qty rack end clamp,
6 qty mid clamp,
6 qty L feet with rubber & special screw....
Same goes to angle positioning solar kits;
- Adjustable front leg
- Adjustable rear leg
- Rail splice kit
- Grounding lug


WHATSAPP::: https:///send?phone=2348170385620

*AUTHORISED DEALER PRAGMATIC TECHNOLOGIES*
All our prag products comes with reliable warranty
*AUTHORIZED DEALER INDIAN INVERTERS / BATTERIES ... Luminous PRODUCTS*
All our products come with 1 year Warranty
*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty.
For best affordable prices contact,
The number 1 credible online store,
Smartcell Global Services,Lagos Nigeria.
Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!

U go fear na... Wow.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:39am On Nov 13, 2018
Dam5reey:
Oga Kiekie, Please open your own website..

You're now bigger than Nairaland, Even konga and Jumia combined no get your kind of stocks.. grin


Good morning Boss.. Haha you made a point Sir but even with websites, I will always be active on Nairaland smiley .. I will work with your advice and update you soon if time permits me ! Cheer's

1 Like

Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:40am On Nov 13, 2018
Trippledots:


U go fear na... Wow.

I hail Sir ! My Regards smiley
Re: Solar Energy, A Complement To FTA by earthrealm(m): 9:46pm On Nov 13, 2018
@SAIPRO AND OTHERS,

whats the physics or rather chemistry behind not topping up water to an fla battery when its not fully charged, could someone shed more light ??
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 10:21pm On Nov 13, 2018
Anyone using LifePo4 battery with BMS 4s ?

I want to know he type of Inverter that can charge it..?
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 4:03am On Nov 14, 2018
There is a tendency for the water volume in a cell to expand during charging especially as the battery temperature rises - if you top up before the battery is fully charged, the electrolyte could boil over during charging and make a mess.

This is why some people leave the battery caps open especially during equalization although then you would have small droplets of electrolyte or a fine mist all over the battery top case.

The only time I would top up before charging is if the plates in a cell were already exposed, I would top up with enough water to cover the cell slightly and then commence the charge. About two hours after charging, I would then top up each cell properly to the correct level.



earthrealm:
@SAIPRO AND OTHERS,

whats the physics or rather chemistry behind not topping up water to an fla battery when its not fully charged, could someone shed more light ??

1 Like

Re: Solar Energy, A Complement To FTA by DMerciful(m): 7:27am On Nov 14, 2018
I have this BMS 4S however I use the charger that came with it. Turned off the inverter charging current.
Dam5reey:
Anyone using LifePo4 battery with BMS 4s ?

I want to know he type of Inverter that can charge it..?
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 7:44am On Nov 14, 2018
ONLINE DELIVERY OF RENEWABLE ENERGY MATERIALS




INVERTER

MICROTECH INVERTER
900VA,12V N46,000
1.1KVA,12V N53,000
1.6KVA/24V N72,000
2KVA/24V N80,000
2.6KVA/36V N105,000
3.6KVA/48V N170,000
5.2KVA/48V N340,000.
5.5KVA/96V N340,000
10KVA/180V N790,000


PRAG INVERTER
1.1KVA,12V N70,000
1.2KVA,12V N90,000
1.5KVA/24V N110,000
2.5KVA/24V N125,000


TRIBAL INVERTER

1.5KVA/24V N82,000
2.6KVA/36V N105,000
3.5KVA/48V N150,000
5KVA/48V N340,000.
5KVA/96V N340,000
10KVA/180V N750,000



MUST POWER STAR INVERTER

4kva 3000W 24V N 220,000
4kva 3000W 48V N 260,000
5kva 4000W 48V N 350,000
6kva 5000W 48V N 400,000
7.5kva 6000W 48V N 450,000
10kva/48V 8000W 48V N 950,000




HYBRID INVERTER

VOLTRON SERIES
1.4KVA/12(30A N65,000
2.4KVA/24V50A N97,000
3KVA /48V 60A MPPT N220,000
5KVA /48V 60A MPPT N310,000
7.5KVA /48V 60A MPPT N430,000
10KVA /48V 100A MPPT N750,000
15KVA /48V 60A MPPT N850,000
15KVA /48V 120A MPPT N890,000


GENEXTECH SERIES

2KVA/24V(600W MPPT) #138,000
3KVA/24V(600W MPPT) #149,000
3KVA/24V(1500W MPPT) #194,000
3KVA/48V(3000W MPPT) #202,000
5KVA/48V(3000W MPPT) #306,000
10KW/48V(14850W MPPT) #1,660,000


STABILIZER

VOLTRON STABLIZER
6KVA WALL MOUNT RELAY REGULATOR #45,000
6KVA WALL MOUNT SERVO REGULATOR #65,000
12KVA WALL MOUNT RELAY REGULATOR #90,000
12KVA WALL MOUNT SERVO REGULATOR #120,000


PRAG STABLIZER

10KVA WALL MOUNT SERVO REGULATOR #130,000
12KVA WALL MOUNT RELAY REGULATOR #120,000
15KVA WALL MOUNT RELAY REGULATOR #140,000
15KVA WALL MOUNT SERVO REGULATOR #240,000
20KVA RELAY REGULATOR #195,000
20KVA SERVO REGULATOR #370,000
30KVA SERVO REGULATOR #470,000


BATTERY

GENEX BATTERY 12V/200AH N 120,000
LONG BATTERY 12V/200AH N 120,000
MONBAT BATTERY 12V/200AH N 125,000
MONBAT BATTERY 12V/210AH N 120,000
ELSON BATTERY 12V/200AH N 115,000
MICROTEC BATTERY 12V/200AH N 105,000
M POWER BATTERY 12V/200AH N 105,000
EASTMAN 12V/200AH TALL TUBULAR BATTERY N115,000
GLT BATTERY 12V/200AH N 90,000
ZEEDIX BATTERY 12V/200AH N 95,000
RITAR BATTERY 12V/200AH N 130,000
PRAG BATTERY 12V/200AH N 140,000
BRITE LITE BATTERY 12V/200AH N100,000
QUANTA BATTERY 12V/200AH N 125,000


BATTERY RACK
BATTERY RACK 2 BATTERY N 15,000
BATTERY RACK 4 BATTERIES N 30,000
BATTERY RACK 8 BATTERIES N 50,000


CHARGE CONTROLLER
ROY SOLAR SERIES
20A 12/24V PWM CONTROLLER N 20,000
30A 12/24V PWM CONTROLLER N 25,000
40A 48v PWM controller (LED) N 50,000
30A 96v PWM controller (LCD) N 120,000
60A 48v PWM controller (LCD) N 95,000


COWIN SERIES
20A 12/24V PWM CONTROLLER N 15,000
30A 12/24V PWM CONTROLLER N 20,000
40A 12/24V PWM CONTROLLER N 25,000
50A 12/24V PWM CONTROLLER N 32,000
60A 12/24V PWM CONTROLLER N 41,000
40A 48v PWM controller (LED) N 25,000
50A 48v PWM controller (LED) N 32,000
60A 48v PWM controller (LED) N 50,000

COWIN MPPT SERIES

40A 12/24/48v MPPT controller (LCD) N 80,000
60A 12/24/48V MPPT controller (LCD) N 130,000

EPEVER MPPT SERIES
12/24/48 /45A N 145,000
12/24/48 /60A N165,000


FANGUNPSUN MPPT SERIES
30A 24V N40,000
60A 48v N140,000
80A 48v N170,000

SOLAR PANELS

JOY SOLAR PANEL
150w MONO -N32,000
200w MONO -N33,000
260w MONO -N54,000


150w POLY –N27,000
200w POLY -N31,000
260w POLY -N52,000

TRINA SOLAR PANEL

300w MONO -N85,000
320w MONO -N110,000


YINGLIN SOLAR PANEL
100w POLY -N22,000
150w POLY -N33,000
200w POLY -N39,000
260w POLY -N51,000
310w POLY -N62,000


100w MONO-N25,000
150w MONO -N33,000
200w MONO -N39,000
260w MONO -N59,000
320w MONO -N74,000

CANADIAN SOLAR PANEL

MONO-
290w. N60,000 (BULK PURCHASE ONLY)
330w. N66,000 (BULK PURCHASE ONLY)

POLY
270w. N45,000 (BULK PURCHASE ONLY)
275w. N59,000 (BULK PURCHASE ONLY)

ACCESSORIES

PROGRAMMABLE Digital timer 15A N7,000
PROGRAMMABLE Digital timer 25A N9,000


BATTERY BALANCER /EQUALIZER 48V 35,000
BATTERY BALANCER EQUALIZER 24V #30,000
BATTERY VOLTMETER INDICATOR #1,700

DC CIRCUIT BREAKER 63A/120V---500V 2 POLE N 8,000
DC CIRCUIT BREAKER 125A/500V 2 POLE N 14,000



DC IRON 150WATTS #9,000

COMPLETE SOLAR SOLUTION


Call-07058562938 Bright Solar Power

WHATSSAP 08187995847

PURCHASE/ DELIVERY /INSTALLATION NATIONWIDE

https:///send?phone=2348187995847



visit our website
www.brightsenergy.com
Re: Solar Energy, A Complement To FTA by earthrealm(m): 8:45am On Nov 14, 2018
NiyiOmoIyunade:
There is a tendency for the water volume in a cell to expand during charging especially as the battery temperature rises - if you top up before the battery is fully charged, the electrolyte could boil over during charging and make a mess.

This is why some people leave the battery caps open especially during equalization although then you would have small droplets of electrolyte or a fine mist all over the battery top case.

The only time I would top up before charging is if the plates in a cell were already exposed, I would top up with enough water to cover the cell slightly and then commence the charge. About two hours after charging, I would then top up each cell properly to the correct level.




Yeah..thats also what i saw during my research...not a big issue if tou ask me..or even batt life threatening..
And the mess or boiling over would only occur if tou topped up to the maximum n beyond.

Saipro was making it seem like he had committed a big blynder grin grin
Re: Solar Energy, A Complement To FTA by Saipro(m): 10:37am On Nov 14, 2018
earthrealm:


Yeah..thats also what i saw during my research...not a big issue if tou ask me..or even batt life threatening..
And the mess or boiling over would only occur if tou topped up to the maximum n beyond.

Saipro was making it seem like he had committed a big blynder grin grin
Okay, perhaps I'm given to sensational writing. cheesy Na my way.

However, temperatures of cells have a large impact on the amount of current absorbed, even small fluctuations. What would you give to bet that the water being added is several degrees below the temperature of the batteries in this part of the world?

I had questioned the rational behind topping before charging but time after time, those batteries/cells paradoxically do not rise as fast neither do they fall as fast in voltage as the others. And I would like to believe it's got little or nothing to do with stratification of the electrolyte. I had done this with my Trojans (both sets) and with my current US Battery set. Tried it with the batteries of family members. Results are similar each time (but nothing as wild as this last one). Merely thought I'd publish it for those whom might not know and whom don't routinely check their batteries.

Anyway, the bottom line is, best and safe practices are just that - best and safe.

PS: Others could try it out and give the house feedback on their findings.
Re: Solar Energy, A Complement To FTA by idsolar(m): 10:42am On Nov 14, 2018
good day my honourables in d assembly. truly this site has bless me greatly. d site is a solar textbook and manual for me. thanks to d originator and others on this site. @saipro, oga George d, pranil, Chris, niyi, d bigrover, makavele (fire for fire analysis), efuro, kiekie, oga zeestone, juo, coogumo, gennex and many many more infact I am greatfull to be part of d house.

I have related with few members and I am impress with d honest way things and issues are resolved. like @niyi was wowed by Morningstar which he displayed, zeestone thank you for d refund of transporters charge after they're have wasted 3days b4 delivery. ur various calls and concern even after delivery is appreciated.

The same way a supplier I respected so much on this forum sold me 35pcs of 260w panels but on site I discovered that 4pcs from this panels are reading 22-23v. notified, he said I should snap and send which I entered hot Kaduna sun to do. I should send d panels to see what he can do. can I tell my clients to wait? no, I bought 2 additional 2 260w panels that cost me 120k then and quietly solve my problem. no call or concern from d supplier. well he loose and still loosing bcause from then till now I have brought over 100pcs of panels for d on going project. I have resolved until d supplier call me, apologise, refund and credit my account with d 120k no deal again. kudos to morningstar. @niyi enjoy, any extra make u look my side o

10 Likes

Re: Solar Energy, A Complement To FTA by makavele: 10:47am On Nov 14, 2018
^^ Good morning to you
Re: Solar Energy, A Complement To FTA by CAROLYN19: 11:40am On Nov 14, 2018
Call us on 08066332919 for your Industrial Power Backup Equipment Such as Gaston Batteries, Emerson/VERTIV UPS, AVR , Outback and Xantrex Inverters

1 Like

Re: Solar Energy, A Complement To FTA by roolnaado(m): 12:03pm On Nov 14, 2018
Update

Hi all, thanks for all the contributions saipro , dmerciful and efuro. I called the installer to complain about the low ampere the panel is supplying. He replied saying the arrangement is okay but the wire he used could be the problem. He changed the wire yesterday but there was only marginal increase in amperage(6a). The panel is unaccesible (nailed on the roof). I am at a crossroad because I have already spent a lot of money


Saipro:

His system is small enough for the money spent on a new CC to be better utilised by a larger PV array. Or so me thinks (below 1kWp, MPPT barely outperforms PWM, assuming the typical 24VDC nominal, short cable runs, etc).


Understood. If the panels are accessible, those info should be pasted on the back. Your installer cum supplier should otherwise have those figures.


The post came after mine. I had no way of telling, at least not from the info previously supplied.

Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 2:37pm On Nov 14, 2018
Oga Roolnaado,

If I may, I believe your battery nominal voltage is set at 24v yes? And your 1.5kva inverter is also 24v?

If that be the case and you have 4 pcs of 24v nominal panels, there is no reason to be using a 2 x 2 config with a PWM CC - essentially you are wasting the power of 2 out of your 4 panels.

100w at 24v (30VmP) is about 3.3a per panel so seeing 6a combined as you reported is just about right with your current config.

PWM cannot use the excess voltage potential you have created by putting two 24v nominal panels in series - it is just wasted power. I believe Oga Saipro already advised you should put all 4 panels in parallel and this is what you need to do.

You should be able to see about 10 to 12amps total from your 4 panels in a 4 in parallel config under optimal conditions - this is what I believe you have to do next to progress this...


roolnaado:
Update

Hi all, thanks for all the contributions saipro , dmerciful and efuro. I called the installer to complain about the low ampere the panel is supplying. He replied saying the arrangement is okay but the wire he used could be the problem. He changed the wire yesterday but there was only marginal increase in amperage(6a). The panel is unaccesible (nailed on the roof). I am at a crossroad because I have already spent a lot of money


Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:28pm On Nov 14, 2018
NiyiOmoIyunade:
Oga Roolnaado,

If I may, I believe your battery nominal voltage is set at 24v yes? And your 1.5kva inverter is also 24v?

If that be the case and you have 4 pcs of 24v nominal panels, there is no reason to be using a 2 x 2 config with a PWM CC - essentially you are wasting the power of 2 out of your 4 panels.

100w at 24v (30VmP) is about 3.3a per panel so seeing 6a combined as you reported is just about right with your current config.

PWM cannot use the excess voltage potential you have created by putting two 24v nominal panels in series - it is just wasted power. I believe Oga Saipro already advised you should put all 4 panels in parallel and this is what you need to do.

You should be able to see about 10 to 12amps total from your 4 panels in a 4 in parallel config under optimal conditions - this is what I believe you have to do next to progress this...



I don't want to belief the panels are 100w @ 24v, it should be 100w @ 12v with a current of ~ 5.7A. That should be the reason for 2*2 config. So at that, he should see around 11.4A (all things been equal, which can never be!). From the pics, I will multiply that figure(11.4) by an efficiency of 60%, ie 11.4*0.6=6.84A. So the current he is seeing is about right.

Note: Those batteries are going to die very fast! Kindly do the needful(buy a 'cheap' 15a 100v mppt Fangpsun CC and connect the 4 panels in series; with that wire gauge am seeing there).

1 Like

Re: Solar Energy, A Complement To FTA by roolnaado(m): 4:55pm On Nov 14, 2018
Thanks. I will have another installer to do this

NiyiOmoIyunade:
Oga Roolnaado,

If I may, I believe your battery nominal voltage is set at 24v yes? And your 1.5kva inverter is also 24v?

If that be the case and you have 4 pcs of 24v nominal panels, there is no reason to be using a 2 x 2 config with a PWM CC - essentially you are wasting the power of 2 out of your 4 panels.

100w at 24v (30VmP) is about 3.3a per panel so seeing 6a combined as you reported is just about right with your current config.

PWM cannot use the excess voltage potential you have created by putting two 24v nominal panels in series - it is just wasted power. I believe Oga Saipro already advised you should put all 4 panels in parallel and this is what you need to do.

You should be able to see about 10 to 12amps total from your 4 panels in a 4 in parallel config under optimal conditions - this is what I believe you have to do next to progress this...


Re: Solar Energy, A Complement To FTA by roolnaado(m): 4:58pm On Nov 14, 2018
Thanks

Oshomo12:


I don't want to belief the panels are 100w @ 24v, it should be 100w @ 12v with a current of ~ 5.7A. That should be the reason for 2*2 config. So at that, he should see around 11.4A (all things been equal, which can never be!). From the pics, I will multiply that figure(11.4) by an efficiency of 60%, ie 11.4*0.6=6.84A. So the current he is seeing is about right.

Note: Those batteries are going to die very fast! Kindly do the needful(buy a 'cheap' 15a 100v mppt Fangpsun CC and connect the 4 panels in series; with that wire gauge am seeing there).
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 5:40pm On Nov 14, 2018
Please confirm if your panels are 100w 24v nominal as you stated or 100w 12v.

Knowing the panel nominal voltage is key to us all giving you the correct advice.


roolnaado:
Thanks


Oshomo12:


I don't want to belief the panels are 100w @ 24v, it should be 100w @ 12v with a current of ~ 5.7A. That should be the reason for 2*2 config. So at that, he should see around 11.4A (all things been equal, which can never be!). From the pics, I will multiply that figure(11.4) by an efficiency of 60%, ie 11.4*0.6=6.84A. So the current he is seeing is about right.

Re: Solar Energy, A Complement To FTA by JUO(m): 5:49pm On Nov 14, 2018
roolnaado:
Update

Hi all, thanks for all the contributions saipro , dmerciful and efuro. I called the installer to complain about the low ampere the panel is supplying. He replied saying the arrangement is okay but the wire he used could be the problem. He changed the wire yesterday but there was only marginal increase in amperage(6a). The panel is unaccesible (nailed on the roof). I am at a crossroad because I have already spent a lot of money


it should be 100w 12v the reason you have 2 in series unfortunately there is no cheap good mppt. The 15a Fangpusun talked about is around 20k. You need to change the charge controller before your batteries packs up, you will also need additional panels
Re: Solar Energy, A Complement To FTA by JUO(m): 5:53pm On Nov 14, 2018
NiyiOmoIyunade:
Please confirm if your panels are 100w 24v nominal as you stated or 100w 12v.

Knowing the panel nominal voltage is key to us all giving you the correct advice.




it should be 100w 12v although he can confirm the panel voltage from the controller terminals. If you have below 40v on both panels just know is 12v panel
Re: Solar Energy, A Complement To FTA by Saipro(m): 2:08am On Nov 15, 2018
Oshomo12:

I don't want to belief the panels are 100w @ 24v, it should be 100w @ 12v with a current of ~ 5.7A. That should be the reason for 2*2 config. So at that, he should see around 11.4A (all things been equal, which can never be!). From the pics, I will multiply that figure(11.4) by an efficiency of 60%, ie 11.4*0.6=6.84A. So the current he is seeing is about right.

Note: Those batteries are going to die very fast! Kindly do the needful(buy a 'cheap' 15a 100v mppt Fangpsun CC and connect the 4 panels in series; with that wire gauge am seeing there).

You're right. I missed the 100W and somehow read 150W (possibly because I worked with 150W 24V panels last week?) My apologies for not being more thorough. He really shouldn't get less than 8.5A for his money's worth, based on the new light you've shed. He needs more of those panels though ... lots more.

And yes, those batteries might have begun a rapid descent into sulphation already.
Re: Solar Energy, A Complement To FTA by idsolar(m): 11:06am On Nov 15, 2018
@Brightsolar. pls confirm if this Voltron hybrid inverters are rebranded axpert or at par. nagode
Re: Solar Energy, A Complement To FTA by DUNKA(m): 3:17pm On Nov 15, 2018
idsolar:
good day my honourables in d assembly. truly this site has bless me greatly. d site is a solar textbook and manual for me. thanks to d originator and others on this site. @saipro, oga George d, pranil, Chris, niyi, d bigrover, makavele (fire for fire analysis), efuro, kiekie, oga zeestone, juo, coogumo, gennex and many many more infact I am greatfull to be part of d house.

I have related with few members and I am impress with d honest way things and issues are resolved. like @niyi was wowed by Morningstar which he displayed, zeestone thank you for d refund of transporters charge after they're have wasted 3days b4 delivery. ur various calls and concern even after delivery is appreciated.

*The same way a supplier I respected so much on this forum sold me 35pcs of 260w panels but on site I discovered that 4pcs from this panels are reading 22-23v. notified, he said I should snap and send which I entered hot Kaduna sun to do. I should send d panels to see what he can do. can I tell my clients to wait? no, I bought 2 additional 2 260w panels that cost me 120k then and quietly solve my problem. no call or concern from d supplier. well he loose and still loosing bcause from then till now I have brought over 100pcs of panels for d on going project. I have resolved until d supplier call me, apologise, refund and credit my account with d 120k no deal again. kudos to morningstar. @niyi enjoy, any extra make u look my side o
* I can bet my solar system that the supplier is the person that loves money more than his reputation and blokus grin Na Yi karya?

10 Likes

Re: Solar Energy, A Complement To FTA by makavele: 3:54pm On Nov 15, 2018
I can bet my batteries that the supplier is a woman grin grin

5 Likes

(1) (2) (3) ... (473) (474) (475) (476) (477) (478) (479) ... (1695) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: loluskysat(m), QuoteJust1nce, Dharyhor, damilonya(m) and 3 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 137
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.