Satellite TV TechnologyRe: Viewing Centre Owners Thread by Dreamflyin(m): 11:16am On Jan 29, 2017
brainy02:
Decision has been reversed
When Biko?
I got an email from Dstv saying the opposite.
My decoders are doing separate channels.
Satellite TV TechnologyRe: Viewing Centre Owners Thread by Dreamflyin(m): 2:17pm On Jan 28, 2017
Collective Account wey Dstv don spoil with channel splitting?
Satellite TV TechnologyRe: Viewing Centre Owners Thread by Dreamflyin(m): 10:34am On Jan 25, 2017
What can be done to Dstv collective account splitting?
InvestmentRe: Treasury Bills In Nigeria by Dreamflyin(m): 11:24pm On Dec 15, 2016
Mfunkynation:
Pls @ what rate did first bank give u for 365 days?
18% flat.
InvestmentRe: Treasury Bills In Nigeria by Dreamflyin(m): 11:22pm On Dec 15, 2016
exclusiveoloori:
Has anyone gotten alert from first bank
Yes. In the afternoon.
InvestmentRe: Treasury Bills In Nigeria by Dreamflyin(m): 9:25am On Dec 14, 2016
Today is another bid day. Let's see.
ComputersRe: Inverter Users : Lets Have Your Experience by Dreamflyin(m): 11:26pm On Dec 01, 2016
I bought a 50amps famicare battery charger for my battery bank (4 200ah, and 2 150ah, 24v).
Connected the cables to the + and - terminal, but the ish is not charging.
Any way to charge a battery bank?
ComputersRe: Inverter Users : Lets Have Your Experience by Dreamflyin(m): 6:18am On Nov 23, 2016
Anyone charging his battery bank with an external charger?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 6:17am On Nov 23, 2016
Any experience with charging a battery bank with an external battery charger?
ComputersRe: Inverter Users : Lets Have Your Experience by Dreamflyin(m): 11:21pm On Nov 18, 2016
Anyone selling a smart battery charger?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 10:40pm On Nov 18, 2016
That's a SUOER?
No no no.
Here's a thorough review...
http://quan-diy.com/misc/scc/suoer20.htm
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 7:17pm On Nov 18, 2016
Anyone selling a smart battery charger?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 10:49am On Nov 18, 2016
Any downside to using an automatic external battery charger?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m):
mm..
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 6:54am On Nov 16, 2016
Hello house.
Thanks for the help so far. Now using 10mm wires and had quite a 25-30℅ improvement.
..but issue now is that the inverter does not charge the batteries. A 2kw inverter.
It could be on for hours but puts in 1amps into the whole thing. It needs a lot of power to come online. My gen 4400w funds it's hard driving her.
How good are Zinox ivertetd or any good inverter that does not need huge startup current?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 2:19am On Oct 31, 2016
earthrealm:
state ur location, maybe some1 here who has knowledge can volunteer to help check ur system out
Onitsha.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 8:26am On Oct 30, 2016
efuro:
i commend your bold choice going 4 mppt.
don't be discouraged, lucky u it has offered u a real opportunity to gain experience you can't buy off d shelves.

by the way it is too early to determine mppt is harvesting less using 2 to 3hrs. in my view.
1.check if ur cables is rated > 6mm (beta if is 10-16mm awg), if OK then

2. disconnect all ur PV config. if ur running 3x2, load & test each set independently, u will surely notice a set probably from ur last setup down d line drawing you down.

3. consider reviewing the type of ur grounding style.

however, try and draw ur installation so dat masters and gurus can attended to u quickly.

my regards
I wish I could draw the connection. An installer did the job for me.
Par the duration I assessed the Cc, I left it for a whole day. It did Max 22amps, same as my two PWMs.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 8:16am On Oct 30, 2016
earthrealm:
Dreamflyin no dey hear.
SOme1 has asked him his cable size and distance..he simply said its god blah blah blah.
NOw he goes off to acquire an mppt cc without eliminating all likely causes.

Dont think we shud bother trying to help u till u start showing some seriousness.
1. how many strings of panels do u have.
2. are u using a combiner box.
3. what size of cable are u using in mm or awg.
4. Whats the distance from panels to cc
5.whats the distance btw cc and batt bank.and what is ur cable size.
6. what is the make of ur panels.specifications..are they all the same make..hope u didnt mix poly n mono. 80w. 150w. 250w on same string etc
I don't have a caliper yet, to check the cable size, but it should be 5-6mm. I tired uploading pic.
Combiner box? No.
Distance from PV to CC would be around 15 - 20feet.
CC to battery should be 3feet Max.
All pv are poly.
8 250w panels.

..but please, I thought MPPTs does a better job. If PWMs were giving 20a at peak, should MPPTs also give same?

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 8:44pm On Oct 29, 2016
Please house, I need help. I'm now as confused as hell.
Since my two 40/40amps PWMs were harvesting 22amps at peak from the 2kw PC array, I thought that installing a Mppt will help issues.
So off to the electrical mart I went for one.
I got offered a Xantrex (Schneider), a ETracer and Itracer (both EP solar).

On installing the ETracer there was no improvement in harvest, rather a decline in harvest. It did 20amps peak.
So back I took it to the dealer and got a refund.
The Xantrex, based on the poor performance of the EP, I insisted in having it test runned on the 2kw panel setup there. Man! it did 18amps while the PWM that was there harvested 32amps off that same PC array.

Now am confused.
I thought Mppt is far better than a PWM?
What's wrong?
It's a 24v system.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 7:26am On Oct 28, 2016
Please gurus, between EP and Schneider xantrex, which mppt is better quality in charge controller?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 6:14pm On Oct 27, 2016
Please how good is Schneider electric xantrex 60amp Mppt?
Someone is offering me one at N130k and an EP 60amp at N150k.
I'm surprised EP is more expensive.
AutosRe: Nissan/infiniti Parts Store On Opebi Road by Dreamflyin(m): 6:36pm On Oct 26, 2016
I changed my CV shaft, but I now gets a low rumbling sound when I accelerate. What could be the cause?
The car is a Nissan Sunny 2010, also known as Almera Classic.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 6:35pm On Oct 26, 2016
Obimind1:
Something must certainly be wrong with ur set up. In as much as pwm is not effective as mppt, its still not doing bad on a small set up. Using my self as an example, 4 of my 150watts panel(600watts) are connected to my 30amp charge controller, and the minimum I get on a rainy or cloudy day is 35amps. This days that we no more experience rain in the middle belt area of nigeria, I harvest up to 60 amps. I formally had the same complaints u're giving currently but luckily I ran into a well experienced installer who discovered that my wires were seriously undersized. After installing the right wires I recorded a great improvement in my harvest. Contact an installer to have a critical look at ur set up and I believe u will be fine.
At 12.00 noon, both PWMs harvests around 24amps(12amps individually).
Explain what you mean by undersized wires, please.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Dreamflyin(m): 1:39pm On Oct 26, 2016
Reprobate:
@dreamflyin , also what size of cable did you ue to connect the panels to the CC/...Also whats the distance
Distance is not much. The floor under the roof.
Cable are good quality PV cables.