What could be the issue here I noticed whenever I'm on inverter and I'm using my phone while plugged in, the phone touch start malfunctioning, even my laptop trackpad and touch also malfunction when plugged in on inverter.. this doesn't happen on gen or NEPA. Abeg who don experience this thing b4
PS: I just noticed if i turn off extension socket, the socket light doesn't go off totally until i unplug the socket |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 6:18pm On Jan 31, 2024 |
Abeg mak una help me put mouth 😔 JoeSef0: Hi everyone. What type of charge controller will be best to use for 5* 350w solar panels on a 24v system (2 220ah tubular batteries) charge controller should be 120k or below (in price) and also the ideal connection should be discussed
Also what brand of inverter will be suggested (min 2kva) Thanks.
Or if i go for the 80a mppt CC on the SMS sunmate Hybrid inverter i used for my previous installation. Will that be enough to handle the job? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 10:22am On Jan 31, 2024 |
I already used an 8mm wires to run the solar into the house, does it mean I'll change that to 16mm or i just need to change the wire i used in connecting the panels together on the roof? olopan: Get a 16mm2 guage wire and connect all the solar panels in parallel since it is a PWM controller
A 12V panel is already 18V Vmp, which will charge your batteries just fine; at 24V, you will be losing a ton of power due to higher potential differences. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 9:41am On Jan 31, 2024 |
Hi everyone. What type of charge controller will be best to use for 5* 350w solar panels on a 24v system (2 220ah tubular batteries) charge controller should be 120k or below (in price) and also the ideal connection should be discussed
Also what brand of inverter will be suggested (min 2kva) Thanks.
Or if i go for the 80a mppt CC on the SMS sunmate Hybrid inverter i used for my previous installation. Will that be enough to handle the job? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 9:34am On Jan 31, 2024 |
Thanks olopan: Get a 16mm2 guage wire and connect all the solar panels in parallel since it is a PWM controller
A 12V panel is already 18V Vmp, which will charge your batteries just fine; at 24V, you will be losing a ton of power due to higher potential differences. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 12:59pm On Jan 29, 2024 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 9:34am On Jan 29, 2024 |
How much is this growat CC? kristien4: Snapshot.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 11:18pm On Jan 28, 2024 |
Okay. Thanks. How do i know the self consumption of the inverter itself? dacool1: Well, I don't think there's anything wrong with the battery, you need to be sure of the self consumption of the inverter I guess it's almost 50 watts.
Note that Lead Acid batteries are fully charged at 12.6v, the 13.2 is just surface charge that disappears in seconds/minutes once charger is unpluged.
You can try charging with an external charger and charge at 14.5v let's see if there's a change |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 5:46pm On Jan 28, 2024 |
For 5 bar it was around 13.2 for the 3 bar it was below 12.5 dacool1: Can you state the voltages at 5bars and 3 bars respectively. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 4:48pm On Jan 28, 2024*. Modified: 5:03pm On Jan 28, 2024 |
Okay okay.. i get you now. Even the 5 pieces 180w 12v i asked about yesterday, i could have just series everything since the pwm charge controller has a max pv voltage is 100 Thanks Drgreatone: I never mentioned 12v, what i said was combining them in series would be better than the parallel connection u used. Ur 3 panels wud be giving you about 100v while the current wud be abt 8amps thus requiring a smaller guage wire and still within the hybrid mppt voltage of 30 to 400. In parallel, ur max volt wud ideally be 36v but in reality can drop to less than 30 at which charging capacity wud be poor or even absent. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 2:07pm On Jan 28, 2024 |
I have this mopower 1.7kva inverter and a 220ah tubular haustrom battery. After fully charged with either PV or electricity, the battery drops 2 bar out of 5 bar in the charge controller screen that's without load, just inverter. Battery is just 6-7 months old and I've been experiencing it since installation. I want to know if this is normal. It was charged full last night. The inverter screen indicated it was fully charged. But while nepa took light the bar and voltage dropped. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 7:25am On Jan 28, 2024*. Modified: 2:01pm On Jan 28, 2024 |
Pwm. According to the controller configuration. The max wattage for 12v panels is 780w, while 180w x5 will give 900w if I'm to connect 24v i can use upto 1500w of panels Penuelseun: is the charge controller pwm or mppt, if pwm connect all panels in parallel |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 4:28am On Jan 28, 2024 |
The system is a 12v (inverter and battery) charge controller is an automatic (12-48v) 60a Ferdiwar: It depends on the parameters of your system (the charge controller and the battery). |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 11:29pm On Jan 27, 2024*. Modified: 4:33am On Jan 28, 2024 |
My bosses here, I have a question
5 12v 180w solar panels to be connected in series to get 24v How'd you go about the connection Remember you need 2 panel's to make 24v. The system is a 12v (inverter and battery) charge controller is an automatic (12-48v) 60a |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 8:43pm On Jan 27, 2024 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 5:03pm On Jan 27, 2024 |
Sorry i must have read you wrong Pv capacity is 300w 3 pieces combined to get 900w As for the hybrid i mentioned. That's the inverter. It has charge controller built in TechGeek777: Hmm, I asked for pv capacity, but you said it's "80a built in with the inverter. It's an hybrid one".
Do we now have Hybrid PV? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 12:57pm On Jan 27, 2024 |
I'm the installer TechGeek777: Are you the one that installed this inverter for customer? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 12:14pm On Jan 27, 2024 |
I understand all you just said. But the 300w panels i used are 36v in paper and it's definitely not 12v (I'll add a diagram that shows it details). So there's no way I'm gonna series 3 panels that arent 12v together, it's gonna exceed the max 48v input for the controller. I might be wrong. Drgreatone: Using a parallel connection wont allow u enjoy the inverter, its minimum mppt voltage is 30v. Connecting it in series would give u better voltage and u wud be using a smaller wire guage as the current wud be reduced. Glad ur feeezer worked on it. I just got same set up and even though by battery sagged to like 11.4 when i put on the freezer, it picked up at once. Mine is even bigger, it's the 310l size and load was around 140w on the inverter. U also need to change the wire btw inverter and battery, the manual suggest using a 22mm guage wire for which i used a 25mm for mine. Wud av used up to 35mm but didnt get around.
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 11:47am On Jan 27, 2024 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 8:46pm On Jan 26, 2024 |
Yes And the screen on it is very detailed, you can get almost all info on the screen. bbally: Thanks for the information and I believe the mppt inside the hybrid inverter is performing very well. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 8:22pm On Jan 26, 2024 |
Parallel Thr inverter should be around 200k+ bbally: Series or parallel connection? How much is the inverter? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 8:13pm On Jan 26, 2024 |
3* 300w africell mono panel bbally: What is the size of the solar panels installed?
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 5:57pm On Jan 26, 2024 |
It's a DC pressing iron It's to be connected directly to the battery not inverter rmoloruntoba: Pls, does this iron what buying and worth using on this inverter |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 5:56pm On Jan 26, 2024 |
80a built in with the inverter. It's an hybrid one TechGeek777: What is your PV capacity? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 12:53pm On Jan 26, 2024 |
Thanks for the input everyone. After charging the battery well with AC and PV... I finally turned of NEPA and run the freezer... It powered it and when the load settled. I turned on all the other loads and the total was just 11-13% load. Out of the total 2kva. So i think everything is good now |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 12:04pm On Jan 26, 2024 |
Just installed if for someone yesterday. This is my first using it also. Customer wanted a 2kva inverter on 12v, the sms inverter was the only one i could find in the market. I was gonna go for kartel 2kva 12v inverter. But i could only find the 24v in the market.. TechGeek777: You are the first person I have seen here using this inverter. PS: the sms sunmate inverter is hybrid with an 80a mppt Charge controller on paper
What's the idle consumption? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 10:53am On Jan 26, 2024 |
Thanks for this.. the inverter is currently running the freezer now, there was nepa light before which was used to start up the freezer, when the light went off the inverter contained to run the freezer.. I'll turn it off and restart the freezer now that the battery is more than 50% charged. As for the battery to inverter connection, i used a 4mm double core cable (not upto 1.5yrds long) cos sms backup inverter didn't create more room to use fit in bigger cable to the battery port on the inverter. I'll try and see if i can double the cable. dacool1: It's your battery or cable. The battery may not be fully charged. Make sure the battery is fully charged then reduce the cable length and increase the cable Guage. I doubt anything is wrong with your inverter.
You'd be surprised it's hitting LVD due to the in ability of your battery to provide the surge needed to start up the compressor. You can solve this problem by adding one more battery to the set up and increasing the cable size.
I won't advice you to power your freezer with just one battery. You'd be exceeding the recommended discharge current since you will be powering other things/appliances too. Your battery would die in less than 2 years.
Forget that 105watts written on that freezer the apperent power is different which increases energy losses so in real life situation your freezer is using up more than that 105watts |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 8:57am On Jan 26, 2024 |
It's a brand new 240ah xtra power tubular battery dacool1: Give info abt the battery. I can bet it's hitting LVD, make sure the batteries are fully charged.
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 8:48am On Jan 26, 2024 |
The battery and inverter are brand new. 240ah Xtra power tubular batery so i don't think it could be the battery. And whenever i put on the freezer the inverter will just turn off ac for some seconds and after i turn the freezer off it will come on again bor i manually off the inverter and turn it on again, which ia quite different from the Inverter screening overload sound. Also I've had same observation with this small 2000w souer inverter with a fridge. It was same reclamation (inverter turns off ac until i turn off the fridge, so i thought those small inverter don't really have much strength that's why it couldn't handle it. But this 2kva inverter is just a surprise to me mctfopt: That SMS inverter must be seriously overrated not to handle this load. I once ran a Scan Frost freezer (non inverter type) of 150w on a 1.5kva 24v Luminous inverter (on four nos 200ah lead acid batteries). Noticed the starting surge is like 6x the freezer's wattage rating as it hits a momentary 800w as it the compressor starts.
If the inverter ain't the culprit, you may consider the battery next. If the battery ain't ok or enough, the startup surge may drop the battery below the inverter's low voltage disconnect. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JoeSef0(m): 5:12am On Jan 26, 2024 |
Good day boses I just installed this 12v 2kva Sms sunmate Hybrid inverter. Owner has a cheat freezer of 105w. My concern now is, the inverter couldn't power the freezer even while all other loads are off. I know freezer has an higher startup current, i just thought the 2kva will be enough to power it.
My question is, what size of inverter will be recomendable for that size of freezer?
|
Technology Market › Re: All Offerup, Letgo, Craigslist, 5miles, Ebay, Amazon Deals.*READ FIRST PAGE* by JoeSef0(m): 10:47pm On Jan 12, 2024 |
Can i get the actual model of this zenbook? There are alot of 13 inch zenbook in the market
[quote author=Dthinkerman post=127908033][/quote] |
Technology Market › Re: The Xiaomi Thread Store by JoeSef0(m): 4:18pm On Dec 30, 2023 |
Is the phone in one piece? If yes, what went bad and what's the storage space? zenith4biz: The following redmi note 7 parts are for sale Motherboard #10,000 Brand new battery, just got from jumia but screen went bad: #5,000 Charging board: 5,000
If you need everything, pay #15,000 |