Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / NewStats: 3,150,853 members, 7,810,281 topics. Date: Saturday, 27 April 2024 at 05:13 AM |
Nairaland Forum / Science/Technology / Technology Market / 24 Hours power supply,Order for your components.(pictures) (8152 Views)
Uninterrupted 24 Hours Power Supply! / Reviewed Cheapest MTN||Etisalat ||AIRTEL Data Bundle ||24 Hours Service|| / Unlock Your Phones-nokia. Iphone.samsung.htc; bb (24 hours icloud removal) (2) (3) (4)
(1) (2) (3) (4) (5) (Reply) (Go Down)
Re: 24 Hours power supply,Order for your components.(pictures) by runz(m): 8:51pm On Mar 26, 2015 |
. |
Re: 24 Hours power supply,Order for your components.(pictures) by runz(m): 9:54am On Mar 28, 2015 |
vote people,no violence. |
Re: 24 Hours power supply,Order for your components.(pictures) by runz(m): 8:02am On Mar 31, 2015 |
Solar power. |
Re: 24 Hours power supply,Order for your components.(pictures) by runz(m): 9:43pm On Mar 31, 2015 |
congrates GMB |
Re: 24 Hours power supply,Order for your components.(pictures) by careidon: 6:05pm On Apr 01, 2015 |
Do you mean 12V or its 2V battery? |
Re: 24 Hours power supply,Order for your components.(pictures) by runz(m): 8:27pm On Apr 08, 2015 |
I mean its 2volts battery. careidon: |
Re: 24 Hours power supply,Order for your components.(pictures) by runz(m): 7:36am On Apr 09, 2015 |
60 amps solar charge controller 12/24/48 volts mppt.110,000 naira only.
|
Re: 24 Hours power supply,Order for your components.(pictures) by runz(m): 8:12pm On Apr 24, 2015 |
The holy grail of mppt solar charge controller 60amps 12/24/36/48/60. Nominal Battery Voltages 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) Maximum Output Current 60 amps @ 104° F (40°C) with adjustable current limit Maximum Solar Array STC Nameplate 12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts NEC Recommended Solar Array STC Nameplate 12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts PV Open Circuit Voltage (VOC) 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum Standby Power Consumption Less than 1 Watt typical Power Conversion Efficiency 98.1% @ 60Amps in at 48 VDC System voltage - Typical Charging Regulation Five Stages: Bulk, Absorption, Float, Silent and Equalization Voltage Regulation Set points 10 to 80 VDC user adjustable with password protection Equalization Charging Programmable Voltage Setpoint and Duration - Automatic Termination when completed Battery Temperature Compensation Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell Voltage Step-Down Capability Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input Programmable Auxilary Control Output 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) Status Display 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total Remote Display and Controller Optional Mate or Mate2 with RS232 Serial Communications Port Network Cabeling Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) Data Logging Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production Hydro Turbine Applications Consult factory for approved Turbines Positive Ground Applications Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) Operating Temperature Range Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C) Environmental Rating Indoor Type 1 Conduit Knockouts One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom Weight - Unit 11.65 lbs (5.3 kg) - Shipping 13.64 lbs (6.0 kg) Dimensions - Unit 13.5 x 5.75 x 4" (40 x 14 x 10 cm) PRICE:120,000 Naira.
|
Re: 24 Hours power supply,Order for your components.(pictures) by runz(m): 8:14pm On Apr 24, 2015 |
runz:Nominal Battery Voltages 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) Maximum Output Current 60 amps @ 104° F (40°C) with adjustable current limit Maximum Solar Array STC Nameplate 12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts NEC Recommended Solar Array STC Nameplate 12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts PV Open Circuit Voltage (VOC) 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum Standby Power Consumption Less than 1 Watt typical Power Conversion Efficiency 98.1% @ 60Amps in at 48 VDC System voltage - Typical Charging Regulation Five Stages: Bulk, Absorption, Float, Silent and Equalization Voltage Regulation Set points 10 to 80 VDC user adjustable with password protection Equalization Charging Programmable Voltage Setpoint and Duration - Automatic Termination when completed Battery Temperature Compensation Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell Voltage Step-Down Capability Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input Programmable Auxilary Control Output 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) Status Display 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total Remote Display and Controller Optional Mate or Mate2 with RS232 Serial Communications Port Network Cabeling Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) Data Logging Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production Hydro Turbine Applications Consult factory for approved Turbines Positive Ground Applications Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) Operating Temperature Range Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C) Environmental Rating Indoor Type 1 Conduit Knockouts One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom Weight - Unit 11.65 lbs (5.3 kg) - Shipping 13.64 lbs (6.0 kg) Dimensions - Unit 13.5 x 5.75 x 4" (40 x 14 x 10 cm) Price:120,000
|
Re: 24 Hours power supply,Order for your components.(pictures) by runz(m): 6:08pm On Apr 27, 2015 |
Good day house. |
Re: 24 Hours power supply,Order for your components.(pictures) by bigdot1759(m): 5:23pm On May 10, 2015 |
Like how much's 2.5kva batry & like how long'll the batry last long if use to power all bulb in a 3b/r flat, 3 ceilin fans throughout nite & use fo like 5hours during day |
Re: 24 Hours power supply,Order for your components.(pictures) by runz(m): 7:33pm On May 11, 2015 |
please call us on 08068627401 bigdot1759: |
Digital LED Billboard Installation & Maintenance Service In Nigeria / HtC myTouch 3G Slide @ 13k / Blackberry Pearl 8100 10k
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 21 |