Function
This command is used to query the information about the ONT capability set profile in a distributed mode.

Format
display ont-profile { profile-id profile-id | profile-name profile-name | all }

Parameters
Parameter
Description
Value

profile-id profile-id
Indicates the ID of the ONT capability set profile. It identifies a capability set profile uniquely.
Numeral type. Range: 1-128.

profile-name profile-name
Indicates the name of the ONT capability set profile. The default naming rule in the system is "ont-profile_x". "x" is the ID of the ONT capability set profile.
Character string type, a string of 1-63 characters.

all
When you need to query the summary information on all the ONT capability set profiles, use this parameter. The summary information about all ONT capability set profiles includes the profile ID, profile name, and binding times of an ONT capability set profile.
-


Modes
Privilege mode

Level
Operator level

Usage Guidelines
To switch the xPON mode, run the diagnose command in privilege mode or global config mode to enter diagnose mode, and then run thexpon mode switch-to command. After the switching, reset the device for the mode to take effect.
When the profile ID or profile name is specified, the system displays the detailed information about the specified profile.
Example
To query the detailed information about ONT capability set profile 1, do as follows:

huawei#display ont-profile
{ all<K>|profile-id<K>|profile-name<K> }:profile-id
{ profile-id<U><1,128> }:1

Command:
display ont-profile profile-id 1
---------------------------------------------------------------------------
Profile ID : 1
Profile name: ont-profile_1
---------------------------------------------------------------------------
Number of POTS ports: 0
Number of ETH ports: adaptive
Number of VDSL ports: 0
TDM port type: E1
TDM service type: TDMoGem
Number of TDM ports: 8
Number of MOCA ports: 0
Number of CATV UNI ports: 0
Mapping mode: VLAN ID
The type of flow control: PQ
---------------------------------------------------------------------------
Binding times: 0
---------------------------------------------------------------------------To query the information about all the ONT profiles, do as follows:

huawei#display ont-profile
{ all<K>|profile-id<K>|profile-name<K> }:all

Command:
display ont-profile all
---------------------------------------------------------------------------
Profile ID Profile name Binding Times
---------------------------------------------------------------------------
1 ont-profile_1 0
2 ont-profile_2 0
3 ont-profile_3 0
4 ont-profile_4 0
5 ONT_PROFILE_HW_OT925 0
6 ONT_PROFILE_HW_HG850 0
7 ONT_PROFILE_HW_HG810 0
17 OT923 1
---------------------------------------------------------------------------
Total: 8System Response
The system displays the queried result when the command runs successfully.
The following table describes the parameters in response to the display ont-profile profile-id 1 command.
Parameter
Description

profile-id
Indicates the ID of the ONT capability set profile.

profile-name
Indicates the name of the ONT capability set profile.

Number of POTS ports
Indicates the number of POTS ports. When the value is adaptive, it indicates adaptive mode, in which the number of POTS ports is set based on the actual number on the ONT.

Number of ETH ports
Indicates the number of ETH ports. When the value is adaptive, it indicates adaptive mode, in which the number of Ethernet ports is set based on the actual number on the ONT.

Number of VDSL ports
Indicates the number of VDSL ports. When the value is adaptive, it indicates adaptive mode, in which the number of VDSL ports is set based on the actual number on the ONT.

TDM port type
Indicates the TDM port type. It can be E1 or T1 type.

TDM service type
Indicates the TDM service type. It can be TDMoGEM type only, that is, TDM service over GPON encapsulation mode.

Number of TDM ports
Indicates the number of TDM ports.

Number of MOCA ports
Indicates the number of MOCA ports.

Number of CATV UNI ports
Indicates the number of CATV ports on the user side. When the value is adaptive, it indicates adaptive mode, in which the number of CATV ports is set based on the actual number on the ONT.

Mapping mode
Indicates the mapping mode between the service stream and the GEM port. In single-bridge mode, the mapping mode can be configured to VLANID, 802_1PPRI, or VLANID+802_1PPRI. The default mode is VLANID. In multi-bridge mode, the mapping mode can be configured to PORT ID. You can run the mapping-mode(gpon profile) command to configure the mapping mode.

By default, the ONT supports the VLAN mapping mode. Each [urlhttp://www.thunder-link.com/HG8245H_p698.html]ONT[/url] can be configured with only one mapping mode.

The type of flow control
Indicates the type of the flow control, which can be PQ, GEMPORT-CAR, or FLOW-CAR.
When the PQ mode is used, you need to define the sending queue of the GEM port packets in the T-CONT. The T-CONT sends the upstream data strictly according to the queue priority. By default, there are eight queues (queue 0 to queue 7) in the system. Queue 7 has the highest priority and the traffic of this queue is assured first.
When the GEMPORT-CAR mode is used, the ONT restricts the rate of data packets carried on the GEM port based on the flow control settings of the GEM port. When the GEM port carries multiple service streams, the default scheduling mode of the ONT determines whether the PQ scheduling, WRR scheduling, or PQ+WRR scheduling is used. If there are multiple GEM ports in the T-CONT, the scheduling mode of the data packets between the GEM ports is also determined by the default scheduling mode of the ONT.
When the FLOW-CAR mode is used, the ONT controls all service streams carried on the GEM port one by one, which is more refined as compared with the flow control in the GEM flow control mode. After the flow control of the service streams is complete, the service streams are scheduled in the T-CONT queue. The scheduling mode is determined by the default scheduling mode of the ONT.

Binding times
Indicates the binding times of the ONT capability set profile.


The following table describes the parameters in response to the display ont-profile all command.
Parameter
Description

GPON Profile ID
Indicates the ID of the ONT capability set profile.

Profile name
Indicates the name of the ONT capability set profile.

Binding Times
Indicates the binding times of the ONT capability set profile.


For more information about the error message that the system displays against a command entered with incorrect syntax, see the "Syntax Check" in Parameter

(1) (Reply)

Urgently Needed.thinkpad T400 Screen Replacement. / Why C Is The Default Drive On Your Computer & Not A Or B? Here’s Why / Hp Envy M6

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 35
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.