What Is The Relationship Among The Alarm Indicators On The EFI Boards? by jorna: 4:31am On Jun 27, 2016
This section describes the relationship among the alarm indicators on the EFI boards in OptiX OSN 6800 subracks.
Product

OptiX OSN 6800
Fault Type

Other
Symptom

What is the relationship among the alarm indicators on the EFI boards in OptiX OSN 6800 subracks if the OptiX OSN 6800 NE adopts the master-slave subrack mode?
Cause Analysis

If the OptiX OSN 6800 NE adopts the master-slave subrack mode, the alarm indicators on the EFI boards in all the subracks are in the same state. That is, these alarm indicators indicate the alarm status of the entire NE rather than the alarm status of the individual subracks.
Procedure

Suppress all the alarms reported by the boards in the master subrack of an OptiX OSN 6800 NE (assume that the boards in both the master and slave subracks report alarms). Then, check whether the alarm indicators on the EFI boards in the master and slave subracks are in the same state.
Suppress all the alarms reported by the boards in the master and slave subracks. The alarm indicators on the EFI boards in all the subracks are off. Then, unsuppress the alarms reported by the boards in the master subrack. Check whether the alarm indicators on the EFI boards in all the subracks are in the same state.
Result

If the OptiX OSN 6800 NE adopts the master-slave subrack mode, the alarm indicators on the EFI boards in all the subracks are in the same state in case of an alarm reported by a board in either the master subrack or a slave subrack. That is, these alarm indicators indicate the alarm status of the entire NE.
Reference Information

None.

(1) (Reply)

PS3 Game Console Needed In Abeokuta / Inverter+battery+installation @85k / This Will Interest You!!!

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 9
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.