Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / New
Stats: 3,152,008 members, 7,814,440 topics. Date: Wednesday, 01 May 2024 at 12:54 PM

Gambro Prizim Hemodialysis Units For Sale (2 Units) - Health - Nairaland

Nairaland Forum / Nairaland / General / Health / Gambro Prizim Hemodialysis Units For Sale (2 Units) (983 Views)

You Need To Use 10 Units In Calenda / Apollo Inks Pact To Set Up 30 Telemedicine Units In Africa / Gambro Prizim Hemodialysis Units (2) Available For Sale (2) (3) (4)

(1) (Reply)

Gambro Prizim Hemodialysis Units For Sale (2 Units) by blackracle(m): 10:55pm On Nov 16, 2011
Gambro Prizim Hemodialysis units (2) available
This are used in intensive care units for critical use
they are continuous care units

This unit does not include water filtration system, tubing and bags

Physical Dimensions
Height: 58 in (147cm)
Width: 26 in (66cm)
Depth: 26 in (66 cm)
Weight: 50 lb (23 kg )

Electrical Power Supply Requirements
Line Voltage: 100/115 VAC 5 A, 50/60 Hz
220/240 VAC 5 A, 50/60 Hz
Input Line Current: 5 A maximum RMS at 100/115 VAC
2.5 A maximum RMS at 220/240 VAC

Anticoagulant Settings
Continuous Delivery Rate: User Settable; 0, or 0.5 to 5.0 ml/hr at 0.1 ml/hr increments; Accuracy of ±0.5 ml/hr
Bolus Volume: User Settable; 0, or 0.5 to 5.0 ml/hr at 0.1 ml/hr increments; Accuracy of ±0.5 ml/hr
Bolus Frequency Range: User Settable; once every 1 to 24 hours at 1 hr increments


Flow Rates
Blood Flow Rate: 10 to 180 ml/min
5 ml/min increments
Replacement: 0 or 100 to 4500 ml/hr
10 ml/hr increments for CVVH
0 or 100 to 2000 ml/hr 10 ml/hr increments
Dialysate: 0 or 50 to 2500 ml/hr
50 ml/hr increments
Effluent: 0 or 10 to 5500 ml/hr

Ultrafiltration Rate
Range: 0 or 10 to 2000 ml/hr
10 ml/hr increments for SCUF only

0 or 10 to 1000 ml/hr
10ml/hr increments for CVVH, CVVHD, CVVHDF
Accuracy: ±30 ml/hr, ±70 ml/3hr, ±300 ml/24hr

TPE Settings
Pre-treatment Hematocrit: 10 to 60% at 1% increments; defaulted at 43%
Total Replacement Input: 1 to 10,000 ml at 100 ml increments; defaulted at 3000 ml
Patient Plasma Loss Rate: 0 or 10 to 10,000 ml/hr at 10 ml/hr increments
Replacement Container Volume: 0 to 5000 ml at 10 ml increments

(1) (Reply)

Resonance Continental Recruiting!!! / Jump Rope Fitness For Beginners / Swollen Womanliness

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 9
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.