Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / NewStats: 3,152,008 members, 7,814,440 topics. Date: Wednesday, 01 May 2024 at 12:54 PM |
Nairaland Forum / Nairaland / General / Health / Gambro Prizim Hemodialysis Units For Sale (2 Units) (983 Views)
You Need To Use 10 Units In Calenda / Apollo Inks Pact To Set Up 30 Telemedicine Units In Africa / Gambro Prizim Hemodialysis Units (2) Available For Sale (2) (3) (4)
(1) (Reply)
Gambro Prizim Hemodialysis Units For Sale (2 Units) by blackracle(m): 10:55pm On Nov 16, 2011 |
Gambro Prizim Hemodialysis units (2) available This are used in intensive care units for critical use they are continuous care units This unit does not include water filtration system, tubing and bags Physical Dimensions Height: 58 in (147cm) Width: 26 in (66cm) Depth: 26 in (66 cm) Weight: 50 lb (23 kg ) Electrical Power Supply Requirements Line Voltage: 100/115 VAC 5 A, 50/60 Hz 220/240 VAC 5 A, 50/60 Hz Input Line Current: 5 A maximum RMS at 100/115 VAC 2.5 A maximum RMS at 220/240 VAC Anticoagulant Settings Continuous Delivery Rate: User Settable; 0, or 0.5 to 5.0 ml/hr at 0.1 ml/hr increments; Accuracy of ±0.5 ml/hr Bolus Volume: User Settable; 0, or 0.5 to 5.0 ml/hr at 0.1 ml/hr increments; Accuracy of ±0.5 ml/hr Bolus Frequency Range: User Settable; once every 1 to 24 hours at 1 hr increments Flow Rates Blood Flow Rate: 10 to 180 ml/min 5 ml/min increments Replacement: 0 or 100 to 4500 ml/hr 10 ml/hr increments for CVVH 0 or 100 to 2000 ml/hr 10 ml/hr increments Dialysate: 0 or 50 to 2500 ml/hr 50 ml/hr increments Effluent: 0 or 10 to 5500 ml/hr Ultrafiltration Rate Range: 0 or 10 to 2000 ml/hr 10 ml/hr increments for SCUF only 0 or 10 to 1000 ml/hr 10ml/hr increments for CVVH, CVVHD, CVVHDF Accuracy: ±30 ml/hr, ±70 ml/3hr, ±300 ml/24hr TPE Settings Pre-treatment Hematocrit: 10 to 60% at 1% increments; defaulted at 43% Total Replacement Input: 1 to 10,000 ml at 100 ml increments; defaulted at 3000 ml Patient Plasma Loss Rate: 0 or 10 to 10,000 ml/hr at 10 ml/hr increments Replacement Container Volume: 0 to 5000 ml at 10 ml increments
|
(1) (Reply)
Resonance Continental Recruiting!!! / Jump Rope Fitness For Beginners / Swollen Womanliness
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 9 |