Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 9:52am On Dec 13, 2024
RickyM:
Welion or SMS…Any suggestion for an inverter?
Sako then sms
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 5:36pm On Dec 01, 2024
elrony:
Mine just got burnt, moved to a new apartment and same day of installation my inverter got damaged. Solar panels hadn't even been attached. I'm confused currently, suspecting house wiring, suspecting installer..

I need help with a good replacement for the inverter unit, installer dey say technicians dem dey talk say dem no fit fix am easily as na older model.

Epp me!

Batteries are lead, just in case.
Inverter brand? Isnt it under warranty?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 5:33pm On Dec 01, 2024
Peterlove11:
It actually rated 10.2kw(10.2kva with pf=1). had to check online, people complained about same rating issue. It's overated. But for its price, it's a fair bargain
What u got was most likely a relabeled pack. The 10.2kva model is slightly different from what you have
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:14pm On Nov 25, 2024
IyanAtiEgusi:
liar cool
Seriously? Like I need to prove anything to a faceless person
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:46pm On Nov 24, 2024
SourYoghurt:
I think my 65w × 2 PC chargers are they culprit. Once I put them off, the noise goes away.
As previously mentioned, check ur dust vents and clean. Clogged vent can also increase the fan noise/duration
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:44pm On Nov 24, 2024
Sakopower:
Li-Wall 51.2V300AH 15KWH
8000cycle times,Smart BMS
A grade new cell
Price: N2,700,000.00
08033213577
My oga at the top. Thanks for the other day. Waybilled a 11kva inverter to me in Abk from Kano via their Lagos office. Sceptical initially but he came through.
NB: Client specifically asked for that model and it wasnt available in Lagos
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:33pm On Nov 24, 2024
samnaija:
First what discharge will his battery undergo to charge 100amps instaneous charge. I would love to see you prove it for a 12v system.

It will not reach 100amps. The charge controller will automatically give accordingly to what the battery needs.

Then you made mention that it is only hybrid that set a particular charge that is wrong.
My fangpuson 80amps charge controller, with so many non hybrid can be modlated or set to whatever charge or current you want. But none the less, mine is set at 80amps and fully loaded with panels, you will not get the complete 80amps
You cant compare ur CC to a Felicity CC. I know u can set ur bulk/float voltage on the felicity CC but doubt u can choose the charging current. I may be wrong though
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 9:57am On Nov 20, 2024
samnaija:
First of all , where Will the 120amps current come from?. Is it from the 3 panels used for the system, definitely not. It cant generate 120amps.
And don't mind individuals scaring you if you have a good charge controller, whatever amps in your battery,you consume is exactly what the charge controllert will give you back. It is a demand and supply curve

Dont reduce the charge of Controller, it should be at the max, you cant generate the 120amps with 3 panels, but it will supply exactly what your battery needs.
He is using 3 580w panels on a 12v system. If the sun is blazing, what makes u think he wont be getting over 100amps into his battery as his CC can not be set to give a particular charge current unlike an hybrid inverter
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:47pm On Nov 19, 2024
KINGKONG:
The aforementioned equipment are not used daily….. Some days not used at all….. the weaving machine and sewing machine are all using servo motor which does not stress the system at all… though I’m planning for an upgrade soon.

It’s just a temporary system in place.

The shop closes by 6pm and hence battery is not really in used…
For a 12v system, u sudnt be doing more than 240w(20amps) of load which I'm sure ur equipment surpasses. Its even worse when u have no loads as all the charging current wud be going into the battery
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 4:39pm On Nov 17, 2024
KINGKONG:
The inverter system is handling load like machine ☺️☺️

As the sun dey fire dey go, Na so the equipment dey jam am dey go

Thanks for recommendation and advise here

Inverter: Tusker 12V 1.5KVa transformer based
CC: 120A Charge controller from Felicity
Battery: 12V GSR Tall tubular battery (To be upgraded soon)
Panels: 580W X 3 from Jinko

Equipment used but not at the same time

Industrial Weaving machine using Servo-motor X 1
Industrial Sewing machine using Servo-motor X 1
Industrial Buttonhole machine X 1
Industrial Button Tacking machine X 1
Ceiling fan X 5 (Short blade)
Why do I feel like u would end up cooking ur battery with that charge controller and shorten the lifespan
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 4:31pm On Nov 16, 2024
Trippledots:
Same here. But na for bungalow height, and my balcony directly overlooks them, so Dem de there like rock.
Waut u mean u just put the panel on the roof without anything to hold it down? What type of roofing and is it slopy?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 4:30pm On Nov 16, 2024
easyyoke:
Make una please help me answer🙏 🙏🙏
Does this occur while inverter is switched off? If nope, switch off the inverter
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 10:16pm On Nov 12, 2024
bassdow:
In simple words, he meant to tell you to have extra money in bank ready to be spent whenever that your new Hybrid inverter goes bad, as e no rugged reach the previous one you were using which is transformer based.

Person wey born new pikin, no suppose allow e money dry as pikin fit sick any moment
You don't need to twist my words just to pass across ur point. We all know u detest all-in-one devices but that doesnt stop their adoption by ppl
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 3:50pm On Nov 11, 2024
Ray1251:
The budget is approximately ₦650,000, and the goal is to power a setup that includes a deep freezer (60W with a starting power of around 120W), a TV (130W), and rechargeable fans (60W when charging and 15W during use). During the day, the system should support charging the fans and running the deep freezer, while in the evening, it should power around 10 LED lights (5W each, totaling 50W), the TV, and the fans when in use, the water pumping machine will be used only when there is power from the main supply.
Apart from getting the hybrid inverter and extra panels, hope u kept funds for protective devices for the hybrid as its fragile compared to the transformer based 1kva u were using.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 11:00pm On Nov 10, 2024
Ray1251:
"I'm seeking advice on upgrading my mother's solar power setup on a limited budget. She lives in an area with an unreliable power supply. Currently, she has 3 × 100W solar panels, a 220Ah tubular battery, and a 1kVA inverter that needs repairs. Due to the worsening power situation, I'm considering upgrading to a 2kVA Sako hybrid inverter and replacing the existing panels with 3 × 550W panels while reusing the 220Ah battery.
Does this approach seem reasonable given the budget constraints?
As u no mention budget, ow do we know its constrained 😁😁😁. You are on the right path. However depending on her daily loads, u cud get away wit 2
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 10:58pm On Nov 10, 2024
Danibestguy:
Landlord said no. I might just have to use just that one.
U can still plead with him to allow u mount 2 with the caveat that u wud be responsible for any roof damage. Had same agreement with my landlord before he allowed me set the panels on the roof. Ensure u now get a good installer who wud not damage the roof
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:45am On Nov 07, 2024
Dam5reey1:
Inefficient decision..
580 X 3 = 1740W.. 40A controller will limit your output to only 580W cause max charging voltage is 14.6..

You need 120A controller, With that amount Just go an buy 12V 2kva Hybrid inverter that has 2000w PV capacity.. that can utilize your 1740w PV for Load and up to 80A charging

This is the efficiency i was referring to in Stand alone.
Perfect option for him.
Its always good if u not sure of something to ask before taking ur decision. Yoruba say person wey ask for road no dey lost. There's no way u can use 3 580w panel on a 40amp charge controller with 12v setting.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 2:12pm On Nov 06, 2024
5kva48v Felicity IVEM hybrid inverter still available for sale
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 12:45pm On Oct 30, 2024
Dageek:
Hello great people, I have been following this thread for a while, took my time to read through existing pages and was able to extract some information, but I’m really locked in between choosing battery.

Based on my power requirements, I would need at least 10kwh battery, this means the pylontech battery of that capacity will cost 4 million plus while felicity 15kwh (13kwh real capacity) will cost more less

This is not my first solar system, I have a 3.5kva 24v system with 2 flooded batteries and 8 x 300w Siemens panels, my plan is to upgrade to a bigger system using Deye 6kw from odyssey, 12 x 555w jinko panels from Fouani , Felicity battery from Naira lander here or Pylontech from Fouani

I would like to seek advise from people who have already used or installed either the Pylontech or felicity of that capacity, which one to choose considering durability, performance and ease of use.

Furthermore, I don’t want to use custom coupled battery because most of these batteries don’t offer communication port which is essential for the system I’m trying to build
Ur last statement isnt completely true. Valto here has coupled a few with the communication port present. The choice is urs in the end
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 11:12am On Oct 29, 2024
1 piece of Felicity 5kva48v IVEM inverter available in Abj for quick sale.
Reason for sale: Client is getting a bigger sized inverter
Whatsapp 0703five7123eight8[/quote]Still available at huge discounted price
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 11:12am On Oct 29, 2024
.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 1:13pm On Oct 24, 2024
HeavenlyBang:
Freezers don't need anywhere near as much as power as you'd think.

The answer to this will depend on how many hours you need the freezer to be running AT NIGHT. Energy storage (batteries) is what accounts for most of the budget in a setup, I'd say.

If you can make do with the freezers running from 8-5 during the day, and then for maybe four hours in the middle of the night, you'll be able to get a setup that isn't really that expensive. Maybe around 800k.
800k for what sir? Inverter and battery alone wud need more not to now talk of panels and accessories with installation fee
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:32am On Oct 21, 2024
Gshems:
How much is it going for. Can I please have your number
45k. Whatsapp Zero703five71238eight
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 11:44pm On Oct 20, 2024
odimbannamdi:
My guy!...lol...low key is the key now o...dress carelessly, off AC inside motor so that you go sweat wella. Then park far, gbe the TV for your shoulder go their shop. But if you look fresh like most of the big men wey I don jam for this thread (I no wan call name), dem go still know sey you dey disguise... grin grin...but baba spend this money naaaaa
That tv heavy small to carry for shoulder and I like soft life. The tv guy I know sabi say I be Doc and i dey fear hin billing plus not bin impressed wit some stuffs he fixed for me so no wan even take the risk
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 11:42pm On Oct 20, 2024
Gshems:
nothing. Just need a charge controller that can charge my 12v 100ah battery using 320watt panel
Location? I have the powmr 80amp pwm charger. U can google it for specs or check jumia
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 7:49pm On Oct 20, 2024
bassdow:
Why not take it to someone else to get their own opinion ?

Just take it elsewhere and say nothing other than it's not working. Let them be the one to check and respond to you
I dont trust the repairers here plus just seeing me come down from a car with it na billing on its own.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 9:39pm On Oct 19, 2024
josephos:
Good evening bosses. Please can I use just 3 units of 555W of Jinko panel to power my 3.5kva 24v system?
It sud but then depends on the VOC of ur inverter.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 9:37pm On Oct 19, 2024
dollarnaira:
Hit my number via WhatsApp.
In ur DM already
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 7:11pm On Oct 19, 2024
dollarnaira:
Are you in Lagos?
Abeokuta but don't mind paying the transport if its someone u recommend
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 6:26pm On Oct 19, 2024
dollarnaira:
True.
Someone fixed a 50" inch LED TV with just 50 naira capacitor.
Abeg u fit send the link. I av a 50in TV that's bin abandoned for over 2 mths. Repair guy says it's the screen but I'm sure its not as i just changed it 2yrs ago and symptoms are different.