₦airaland Forum

Welcome, Guest: RegisterLoginWith GoogleTrendingRecentNew

Stats: 3,330,384 members, 8,445,246 topics. Date: Tuesday, 14 July 2026 at 04:49 PM

Toggle theme

Drgreatone's Posts

Nairaland ForumDrgreatone's ProfileDrgreatone's Posts

1 2 3 4 5 6 7 8 9 10 11 12 13 14 (of 21 pages)

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 6:23pm On May 10, 2024
TechGeek777:
Bro, get SMS it's cheaper and better IMO.

SMS Now have four Chinese repairers in Alaba, according post I sae yesterday from their official Facebook page.

Nominal Voltage Range: 240v(for 12v/24v/48v)

12v PV Voltage Range: 30v - 400v(same as max voc)

24v PV Voltage Range: 60v - 450v
48v PV Voltage Range: 60v - 450v

Max Voc(500vdc) for 24v & 48 respectively
That's nice. Use a 2kv12v sms inverter and it's bin doing just fine.
Had issues with the fan always on most of the time when working but recently decided to clean my anti-dust kit. Was so dusty but after cleaning ,fan just comes on occasionally.
2ndly noticed it wasnt always charging my battery well esp when input is around 200-300w (was using 3 300w panels that increasingly looks fake) but then guess thats why its hybrid. I added 2 more (fake)panels to take the pv volt over 150v and it charges better once I'm getting 350w upwards.
Hoping to get original panels to swap the fakes and see just ow well it wud perform
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone:
Sapiosexuality:
To those running solar, I'm just curious. When last did you use your generator? Did you have to sell it after installing your solar?
Not sure i av put it on this year at all. Just serviced the gen 2/12 ago and placed it in the store to be breathing. Almost put it on around that nationwide blackout but it was restored before i did
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 9:33pm On May 07, 2024
Dam5reey:
Add them up

Sunking no be DIY packs Lol
That's expensive ooo. We need to know type of inverter and panels used sha to know its worth the fee. That firman 550w,shey e dey effectient pass its jinko counterparts ni? Trying to calculate something
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:34pm On May 07, 2024
Dam5reey:
Well, going by 10KWH LFP Sunking, 3.5KVA, and 4500W panels, for 11M is not bad, similar prices on Sumec Fireman, Pylontech Fouani LG, and co.
Unless those sunkings are crazily expensive... The 3.5kva inverter and panels no reach 3m na
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:31pm On May 07, 2024
durodee:
grin grin

The money not much o! Just like 11million sir!!!!!
This installer get building project e dey try finish on time wit client money
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 11:13pm On May 06, 2024
HeavenlyBang:
I'd be surprised if Powmr has repair centers anywhere in the world, since what they are really do is rebadge hardware from SRNE.
Are u sure about this your last sentence? Wud u say same of must/felicity?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 5:00pm On May 02, 2024
odimbannamdi:
Wait till tomorrow... grin
U dey whine me abi.. I fit still reach out to u for that mppt if my plans click well.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 4:33pm On May 02, 2024
I have come again ooo with my inverter palaver. Finally added 2 300watt panels to make 1500watts on my 12v hybrid and input went up to 550watts from 350 at peak hours. However i know from small geography and online gist that the sun move from east to west but which one is now sun that was facing my panel when I install initially is now behind it. My roof is south facing by the way. Pls when wud the sun come around too if u know 🤣🤣🤣🤣
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 5:47pm On Apr 29, 2024
Jefferyzz:
SMS hybrids are decent,I have installed 2 this year and no fault so far. I'll advise u look into 24v rather than 12v. Max Ur battery will charge is 960w
What do u mean by ur last sentence? Not clear
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 5:46pm On Apr 29, 2024
ebrymDIY:
Hello Guyz,
I just needed a professional opinion on this.
I currently have a 12V system with 1000W(4X250) PV in use for about 3years connected to 2 220AH tubular with a 60A CC.
Experience has been good but I'm thinking of upgrading to a Hybrid system. Reasons been that I want to do it in phases myself.
Base on the research in this thread i was able to drill down to the following hardwares:

SMS Hybrid Inverter 2kva/ 2000W 12V (Mppt 80A)
625W X 4 Jinko PV due to space.


However, based on my research, I'm skeptical about the inverter ability to handle the energy from the panel or go the route of upgrading to a 24V system with 120A CC with same amount of panels due to space.

My questions are:
1. Has anyone used that Inverter and whether it can stand test of time.
2. Based on the ratings I've seen for the inverter being 4000W for PV, with it be able to handle future PV addition.
3. Would you advice upgrade the system to a 24V system with 120A CC.

NB: Everything is within a budget and can't exceed but has been prioritized.

All opinions are welcome.
Does ur present system charge ur batteries full? Guess u combined batteries in parallel. How did they combine the panels for you? Is the CC Pwm or mppt? Max a 60amp wud take theoretically is 720w and u using 1000w of panels
To answer ur question
1) Its actually 2kva/1600watt inverter. 3mths old now and doing its work. Comes wit 1 year warranty
2) The max panels u can use is 3000watts
3) why do u want to change ur CC. Is ur present specs not carrying ur load. Since u already av 2 batteries, I'd advice u just get a standalone 24v inverter, change ur battery to series and add more panels to ur CC
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 4:02pm On Apr 28, 2024
durodee:
I will advice you STRONGLY not to sell. You will not be able to get it at the price you sold it if you need it back . Moreover, you won't have any backup in case anything happens. Find money for your upgrade. You will have reasons to remember this advice in the future.
I'd keep mine if i was in his shoes too but then he knows whats best for him
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 4:01pm On Apr 28, 2024
obinna37:
thank you so much for this,many people are afraid to buy hybrid inverter because of difficulty of repair
I have my shortcomings with hybrid based on my experience. If its a 12v system, I'd advice standalone systems. Advantage of the hybrid is it wud take more panels compared to it's standalone charge controller eg my 12v hybrid can take up to 2500 watts yet the mppt won't go above 720w theoretically
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 1:52pm On Apr 28, 2024
Sapiosexuality:
Exactly what I will do. I will sell it. I'm getting panels first. Then inverter and battery.
I'm interested if the price is right.. whatsapp zero 7035seven1 twentythree 88. Thanks
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 1:38pm On Apr 28, 2024
obinna37:
sorry if I may ask, which of the device did he repair for you, what's the fault
Brand new must 5kva hybrid inverter that refused to supply load after setting up. Repaired under warranty.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 3:57pm On Apr 27, 2024
Deluxe8000:
I want the best possible combination to generate enough power from the panels to use at the same time charge my battery. I have 2 150w 12v panels. I need to add more panels.
U should av just stated ur panels spec and nos and the battery set up u want to use it for. Also type and specs of solar charge controller. The experts can then guide u on how to go abt it
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 3:54pm On Apr 27, 2024
luvlyoracle:
Just asking if you use all these dumb inverters without editable settings and you don’t have solar what’s the best way to charge your lithium battery.
Would really appreciate y’all input it’s been giving me issues lately
U cud get a dedicated lipo4 charger and use with a satchet inverter
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 3:50pm On Apr 27, 2024
zeestone99:
Hi. You can Bring it to our service center. It's an hardware issue. We fix all kinds of inverters.

Call/chat 08117..39829.4
Tested and trusted 🙌🙌🙌🙌. Speaking from experience too
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 10:03am On Apr 27, 2024
Deluxe8000:
Shomolu, bariga, yaba area installer with 2s2p experience needed.
Any installer can do 2s2p. Guess u must av done ur homework to arrive at this sha but pls praytell us why u decided on it. Thanks
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 10:01am On Apr 27, 2024
kristien4:
hello boss, do you use breaker between your inverter and battery, is it advisable??
U didnt mention type of inverter and battery? Some inverters wud recommend putting a breaker between them and the battery so check ur manual too
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 9:08pm On Apr 26, 2024
adeshina36:
Good evening

Please I have this kind of configuration setup in my apartment

5kva 24v Inveter
400Watts Solar panels (5)
220ah battery (2)
60amps charger

My question is whenever I try charging with Nepa light o shows it fully charged within few minutes but when it’s on resting stage meaning when it not connect to any form of charge and I check the battery I get 77% even while on solar it shows it fully charged but at the end of the day I see 75% please how can I get it charged to 100% or should I just ignore the fact that it say fully charged and continue charging please any help would be appreciated. Thank you 🙏🏾
The 75% u are getting could be a factor to voltage sag common with tubular batteries. Could also be a factor of the load u put on it
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 9:02pm On Apr 26, 2024
Trippledots:
You put about 2.5kva load on your lead acid battery?!!!

How are we even sure the panels capacities are real, the size of PV cables are optimal, etc

Your installer didn't give you Dos and Don'ts for your type of systemhuh Abi na those type of installers wey de promise 24hrs on top 2 battery....wahalad.

Let me give you some tips for this battery
1. Ideally You shouldn't load your batteries more than about 500watts.

2. You should not use your battery below 50% which is roughly around that 24v you are seeing.

3. Ensure electrolyte level is within range using the hydrometer screwed on it.

4. Ensure your battery charges till float after every deep discharge
That 55% wud drain his batteries to 50% in less than an hour. Reduced lifespan too for the batteries as he's drawing almost 50amps from each battery.
Perfect recipe for failure. He needs to sit his installer down to explain what he did and how to pamper his system.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 7:15pm On Apr 26, 2024
adeshina36:
Good evening

Please I have this kind of configuration setup in my apartment

5kva 24v Inveter
400Watts Solar panels (5)
220ah battery (2)
60amps charger

My question is whenever I try charging with Nepa light o shows it fully charged within few minutes but when it’s on resting stage meaning when it not connect to any form of charge and I check the battery I get 77% even while on solar it shows it fully charged but at the end of the day I see 75% please how can I get it charged to 100% or should I just ignore the fact that it say fully charged and continue charging please any help would be appreciated. Thank you 🙏🏾
What do u mean by 'continue charging'? The inverter/charger sud trip of once battery is full. What's ur load like during the day? Ow many percentage is ur load? Ow long do u run it before it reaches 50% (24.0v)?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 7:12pm On Apr 26, 2024
adeshina36:
Currently after charging it since morning this is what I get as the voltage. Just about to use now to know how many hours in total it will last.
I'm seeing 55%, is it my eyes or what's showing? That 24.0 means ur battery is already at 50%
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:50pm On Apr 23, 2024
QuoteJust1nce:
Ouch. Too late! Drgreatone should be in possession of it soon. He messaged first. Sorry mate
Thanks boss
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 4:55pm On Apr 23, 2024
QuoteJust1nce:
how much you get lol grin grin grin
Moreso, you gotta be in Lagos
Zero 7 zero 3571 two 388
Pls lets WhatsApp
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 2:50pm On Apr 23, 2024
QuoteJust1nce:
Have you asked nicely and I said no?
Let me ask nicely... Can i av the 5g router. Wud be a big upgrade to my 4g 😁😁😁
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 10:55pm On Apr 22, 2024
walexsos:
Its 38v that is on the panel while i get 103 for the 3s combination.....note ...i am not an installer if my answers aint adequate enough
If ur panels VOC is 145, then u can still do a 4s connection. U already at the upper limit of what ur charge controller can take so adding panels wud be putting it at risk. It cant take more than 3300watts and u already on 3600watts already.
Does ur battery get full during the day? Ow much is ur total loads during the day/night? U may av to upgrade ur charge controller to 80a/100a if u are to add more panels. A lithium battery wud be a good replacement as it can take a higher charge current but this wud only make sense if ur present battery bank is weak already/needs replacement.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:21pm On Apr 22, 2024
walexsos:
The voc of the charge controller is 145v
U didnt add ur panel's own
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:20pm On Apr 22, 2024
Anyone wit a functioning 60amp mppt they are not using or willing to dispose of at shikini price? Pls holla 😁😁😁
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 8:11pm On Apr 22, 2024
TechGeek777:
Growatt is far better, heard Gennex is not too good with warranty on their inverters.

If you are not getting VICTRON, get DEYE, but if Deye is above you budget, get GROWATT, if Growatt is still above your budget get SRNE.

Any high frequency inverter outside above 4 mentioned inverters, just get SMS Sunmate Inverter if going for 24v or 48v.

NB: iPowerPlus 5kva is still good if going for low frequency inverter.
Must inverters nko?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 11:36am On Apr 22, 2024
Penuelseun:
My old powmr has a bug that sometimes changes the controller to pwm mode when the battery gets full and load is applied, I will have to switch the solar input off and on a few times before it returns to mppt mode, note that this only happens on 12v batteries, never happens on 24v systems
Oh ok. Thanks
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Drgreatone: 11:35am On Apr 22, 2024
isangjohnson:
I used HSI and Zumax. If the panels are well oriented and the correct size wire was used, then the charging system of the hybrid inverter is the issue.
I had an issue with of one of the hybrid inverters I installed for a customer and suspected it was related to float bulk.. I was unable to get an acceptable margin of float bulk that could comfortably charge the Lfp battery to full. When I set it to the range of 13.8v to 14v, about 9a or thereabouts was coming in from the pv but when I pushed the setting further to about 14.8v, I was seeing 25a and above. I couldn't charge the Lfp battery with 14.8v and I later introduced my spare 60a epever Mppt external CC into it and everything was in order.
Yes, they facing south and are connected in series with a 6mm wire. Tried ur settings but nil change.
At a point was getting abt 180w from the panels but only abt 5a is going into the battery. Highest amps gotten since av gotten it was around 11a and that was when no loads on it and abt 350w from the panels.
Bin advised to get an extra panel and if no change, wud get the external CC.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 (of 21 pages)