Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 1:06pm On Jun 21 |
Tidot: Good morning nairalanders,
Any idea the cost of a pile point that will be 26metres deep. I intend to use driven pile. Location is on the mainland and area is really water logged. I think Segymoor has worked in that location before. Contact him for more detail information and probably what you should be on the cost or budget. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 7:34pm On Jun 14 |
This thread is not lively again.....
Chai!!!!!!! |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 10:10am On Jun 08*. Modified: 11:42am On Jun 08 |
Kool Celepope: Hello Electricians in the house. I was given the below quote for electrical wiring in my ongoing 6 bedroom duplex with an ante room, main living room and two small family living area. Kindly assist to help me scrutinize the quote as I think the person that connected me to the electrician might have told him to inflate the quote. Your response will help me a lot. All the people that dropped comments are all right but let look at it this way. If the client is buying inverter AC and the distance from DB to each AC unit is not far or more than 10m. I will surgest 2.5mm cable is very much okay. But if the client is yet to decided on the type AC units is installing, the 2.5mm can be changed to 4mm. The size of cable as specified in the IEEE regulation is 4mm for the conventional type of AC. Also, the new design of AC units these day is energy efficient. For the water heater 2.5mm cable is pretty much okay. If the project is East, the best cable in those area is Cutie and it's very good and expensive. Cutix cable and Nigerchin are of the same quality. 2.5mm cable is for sockect, let the electrician change the size. Let him include 1.5mm cable to the lighting cables for the mains coming from the ditribution board and 1mm can be use for looping. Seeing the floor plan or electrical design drawings will help us give the estimated quanties of cables required. Our brothers from east like building mansion. I have a project in Anambra presently and I know the reason why I said mansion. |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 12:12pm On May 16 |
Pls beware of this fraudster called LIQUID POINT ENERGY LIMITED. He requested for DB's and send me a fake transaction receipt. Pressuring me to deliver that the delay from crediting my account is because of inter Bank transfer. Till today no money has been credited to my account. Pls don't a victim. Thank God for my life. His number is 08080677791
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 4:39pm On May 08 |
darc: You need a QS He is asking for rough estimate. Might be ±5 or 10% |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:17pm On Apr 29 |
ArcToyin: I will also whatsapp you for the prices. THANKS Ok |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 3:17pm On Apr 29 |
gaeul: Please, what type of roofing is this called. Thanks Look like Gerald roofing sheet |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:02pm On Apr 25 |
Deeegbee: What is the difference between a 3/4 HP and that of 1.5 HP? 1.5hp is more powerful than 3/4HP if they are of the same brand. 1.5HP will pump faster than 3/4HP. If you have a very deep borehole pls don't go for 3/4HP because of head/height |
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 9:12pm On Apr 20 |
Good evening |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 6:18pm On Apr 08 |
OgwuEgo: Update your price list i want to have an estimate of what it will cost me to wire a bungalow. You can send me WhatsApp message on 08033643191. I will forward you 3or 4 different brands Probably ce change almost every month now. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 2:31pm On Apr 07 |
inze: You mean @topsy23 Thanks boss |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:32pm On Apr 02 |
Call |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:01am On Mar 30 |
solomonjac: Good day Senior men in the house. Please how can this WC be plumbed (P-TRAP) and channelled to the window side without and issue of odour synonymous with S- trap since the WC is not directly by window Pls help 🙏 a novice Are you talking about the arrangement of the toilet? |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 1:23pm On Feb 24 |
rotecch77: Who is a Builder? A builder is a licensed professional or contractor who manages, coordinates, and executes the construction, repair, or renovation of residential and commercial buildings. They interpret blueprints, hire subcontractors, procure materials, As defined by Google |
Properties › Re: Electrical Piping Both Surface And Conduit by topsy23(op): 1:55pm On Feb 22 |
Call us today
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 2:48pm On Feb 20 |
cash1115: I sincerely want to appreciate Engr. Topsy for giving me a big contract in Anambra State. We have been working on this project since September last year, and I am truly grateful for the trust and confidence you placed in me and my team. Your support and belief in our craftsmanship mean a lot to us. May God bless you abundantly, sir. To all my wonderful clients who have been reaching out and contacting me even without me posting on Nairaland, I sincerely appreciate your trust, referrals, and continuous patronage. Your confidence in our work speaks loudly, and I do not take it for granted. And to all our respected clients on Nairaland, this is to officially inform you that His Grace Interior Decoration is back — bigger, better, and stronger! We are fully available and ready to deliver quality, standard, and durable interior decoration services. Thank you all for your continuous support. His Grace Interior Decoration Quality, Excellence & Durability Guaranteed. Thank you for the excellent work in Anambra, I also appreciate your patience and endurance. Your work really speak volume of you. You really proof yourself on that project despite all the changes in the pop design. Thank you very much for keeping the relationship alive. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 5:09pm On Feb 08 |
sonnie10: Ok no problem.
It’s going to be a new connection. There is no existing one. 10mm cable should be able to carry sir. What's the length |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 2:39pm On Feb 08 |
sonnie10: I need one asap but na #350k I go pay. Do I need armored cable to connect to soundproof gen? Sir, 360k is the amount from their company, the 5k is just the transport to pick it up. As for the cable, I need to know what happen to existing cable andbefore we change it sir. Also the size is important too. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:12pm On Feb 07 |
sonnie10: 7 ac 6 water heater 1 gas/electric stove 1 washing machine/ dryer 1 Over the range microwave With the listed items above, you will need up to 8-ways 3-phase sir. The socket and the lights are not part of items you listed above. 8-ways 3-phase DB 365,000 Schneider product |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 1:25pm On Feb 07 |
sonnie10: Thanks for the response. How much is the best 3 phase db? How many ways sir, we have different ways 4-ways 6-ways 8-ways 12- ways The number of ways will depend on the size of your building. Pls give me the breakdown of the below items -number of AC -number of water heater - cooker - Etc |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:41am On Feb 07 |
sonnie10: My boss, quick question. Do I need a 3 phase distribution box? An electrician came and said I should change the current 1 phase to 3 phase. How accurate is this information? I don't know the size of your building, and overlo😒 ading can caused what happened. If you are using a single phase distribution board, it means all load will be on a phase and it can overloading if the size and the rating of the main breaker is lower than the internal load. If you change to 3-phase distribution board it means all load will be distributed on the the 3-phase . Again the breaker might be inferior too because there a lot of fake breakers in the market theses days. I received a call from a client this week Wednesday telling me that they have issue on a yellow phase. The breaker has already melted and the cable has started burning. We visited and check what happened, on getting to the estate we discovered all breakers are fake and the rating of the breaker is not up to what was written on the breaker. We brought a new breaker and change the breaker that got burnt. Now we about 17 breakers in the estate of panel . They even use Schneider breaker bought from Alaba. So, you might need to check the breaker very well too. Thanks . |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 4:04pm On Feb 02 |
dapotemi: Hello sir, pls where can I get this breaker. It's 125amps MCCB 4 pole (Schneider) What should I budget pls. @twinskenny @Tope Call this number +2348060934377, his name is TIMILEHIN. But what happen to the existing breaker |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 4:42pm On Jan 16 |
Ndyoo: Hi Topsy23,
I was waiting for them to send me the design drawing so that I can reply you but I kept getting tons of excuses. Well I am not into the Wall bracket light. It's a 6 flats of 2 and 3 bedrooms on each side. Thankyou for the information. Not a problem boss. 5pkts double knockout box won't be enough for the 6units of 3 and 2 bedroom flats. See my breakdown below: Kitchen 6units Minimum of 3double for each kitchen, making total number of double in all the kitchen 18numbers I. e 3*6= 18,. Remember 1pkts of 3*6 knockout box contain 5pcs . For 5pkts it means total number 3*6 is 25pcs. Sitting room will have minimum of 3 double sockets, so 3*6=18. Making total number double knockout box to be 36pcs. Approximately 8pkts. Changeover location will have one each. Rooms can have 2 or 3 single sockets depend on client decision and also location.. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 3:07pm On Jan 12*. Modified: 3:22pm On Jan 12 |
temi4fash: I hear this a lot this days.. that people no longer use will bracket..
So what was used to replace the wall bracket?
Any ideas The wall bracket has been replaced with ceiling light/recess light/spotlight./Strip light. Some clients still use wall bracket in a rented apartment/s. Like I earlier said; ONE MAN'S FOOD IS ANOTHER MAN'S POISON. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:42am On Jan 12 |
Ndyoo: Engineers and Electricians in the house, this is the quote I got for the last flour of my 6 flats 2 storey building . Is there anything missing? I am more concerned of something missing and of course of the quote. I am more worried about the fittings... Don't think anything is missing here except for him to change the Y-Box to 4-way box. Having Y-box means you are using wall bracket light on the project. Wall bracket light is becoming old fashion of electrical installation. Although some people still cherish it because ONE MAN'S FOOD IS ANOTHER MAN'S POISON.. The quantity of conduit pipes quoted above might not be enough based on your description of the project and. 6 flats(but number of bedroom was not stated). Your design drawing could have helped in giving a proper quantities of materials needed and also to guide you more on the installation process and procedures. Thanks |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 5:51pm On Jan 08 |
Cables price has gone up again |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 5:21pm On Jan 07 |
Beframia: What are the factors to be considered if one wants to connect to a borehole who is about 200m away? Please note that the borehole is already in use and sited in a residential property. Thank you. @topsy23 @rotecch77 What you should consider is -Size of submersible pump that can pump to the height mentioned above. -Flow rate. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 7:19pm On Jan 06 |
Noworries11: Again, thank you so much Our site supervisor is pressurising to stock more cements that would be used, reason he's been informed by the seller that price is about to/has gone up to 14k. Anyone has got this info too? Too much pressure though it won't be funny if it turns out to be through. Person still find money to fund project Not sure about the price increase but recently all cable manufacturers increase their prices. And the increament is about 30℅. God will help us in this country. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 2:13pm On Jan 05 |
Noworries11: Great people How can I double check the cureent price of a bag of cement? And also tipper cost of semi sharp/ sharp sand? Location is awka - agulu axis anambra states. Thanks @ Nnewi ; Cement 10,000 Plaster sand 10ton 200,000 Sharp sand 10ton 240,000 |
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 5:35pm On Jan 02 |
Compliment of the season to everyone |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 5:08pm On Jan 02 |
Happy new year to everyone. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 5:58pm On Nov 15, 2025*. Modified: 7:56pm On Nov 15, 2025 |
sonnie10: People, the block wall in that pool is called retention wall, it prevents the soil around the pool from pushing directly on the yet to be installed concrete walls. Yes you are right sir or retaining wall. To prevent the wall from collapse. The concrete casting will later be done. Weldone@ Rotecch77 |