*** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 12:19am On Sep 01, 2017 |
Client : Engr. Peter Project: four flats of one bedroom apartment Location: Enugu, Nigeria Duration: not specified Contractor: Capital Construction co. Ltd Welcome ladies and gentlemen, co-engineers, contractors, investors and observers, it is our pleasure once again to share through this trend every necessary details on how this abandoned structure will emerge an abode. Please follow me , this is where we are starting.
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 7:57pm On Sep 02, 2017 |
The drawing of the structure above is not handy to know some details concerning the building. However we have to run some check on the foundation to know its capacity and more. Considering the foundation dept, the pillar iron bar/size and also the concrete pillar, so we decided to make it a storey of four flats. There we go... 1 Like
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by raymondFirstborn(m): 8:19pm On Sep 02, 2017 |
dubemcapital: so what kind of advice do you need now am a quantity surveyor and also a contractor |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 8:29pm On Sep 02, 2017 |
Formation of Wood structure just started
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 9:04pm On Sep 02, 2017 |
raymondFirstborn: Your advice can be of a great help you know, no knowledge is common. |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 9:48pm On Sep 02, 2017 |
Step formation and space management are both important here. The original step is not lengthy enough to contain double stairs but had double column boxes. So we have to make it a single flight to enable us have a good rise and more
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 1:09am On Sep 04, 2017 |
More pics 1 Like
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 12:27pm On Sep 04, 2017 |
Steel workers are already on it...
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by Jimbiz(m): 12:53pm On Sep 04, 2017 |
Nice job sir.
check my signature |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 7:28pm On Sep 04, 2017 |
Damp nylon is important at this stage because of Cement workability and neater job.
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by Nobody: 7:33pm On Sep 04, 2017 |
Excellent, following. It's nice to see doers, real doers, not paper tigers with no demonstrated project to their names 1 Like |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 8:54pm On Sep 04, 2017 |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 9:01pm On Sep 04, 2017 |
Filling up the block holes before the slab cast is better done now and some cleaning in the pillar columns too for good result. 1 Like
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 9:02pm On Sep 04, 2017 |
EgunMogaji: My oga, welcom on board sir, thank you very well.... 2 Likes |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 10:43pm On Sep 05, 2017 |
Irrespective of the thickness of the slab, slab reinforcement is very key to avoid vibration and more.
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 10:23pm On Sep 06, 2017 |
Ready to cast the slab, fitters, carpenters ,electrical and mechanical are 95℅ ready... In the absence of biscuit ,hard cord stones played the role.
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by austin2all: 8:14pm On Sep 07, 2017 |
Very solid work. I'm impressed. |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 5:58am On Sep 08, 2017 |
austin2all: Thank you sir, I'm encouraged. |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 6:08am On Sep 08, 2017 |
Other fittings and finals before slab cast
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by austin2all: 10:06am On Sep 08, 2017 |
dubemcapital: kudos bro. i've been trying to contact you on whatsapp but i'm sure you are overwhelmed with projects. you will be too busy to pick calls as well. |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 7:06pm On Sep 08, 2017 |
austin2all: Sorry about that, pls try whatsapp with this number 08030799100 |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 8:54pm On Sep 08, 2017 |
The first stage of casting ongoing... I always prefer to take on the stairs first, then beams and lastly the slab.
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by austin2all: 11:32am On Sep 09, 2017 |
Why was a membrane used for the slab casting at deck. Is there any significant advantage as to warrant the cost implication. |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 6:25pm On Sep 12, 2017 |
austin2all: Yes, it has good advantages. 1.)The water that drips out of the concrete during or after casting a decken reduces the strength of the concrete cast, so the polyethylene sheet prevents that. 2.) it also play a very important role in retarding moisture from coming up through the concrete and into the structure (on foundation). 3.) Is commonly used as a damp-proof membrane with oversite concrete for all but severe conditions of dampness. 4.) It saves materials (concrete) from escaping (not the water this time) in between two planks that is not closely lapped. 5.) It makes the work look beautiful and strong. Etc. 4 Likes |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 12:37pm On Sep 13, 2017 |
See more
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 9:06am On Sep 14, 2017 |
More pics
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 7:18am On Sep 20, 2017 |
OK, we have to move on... See details before that : 204 PCs of 1*12*12 85 PCs of 2*3*12 35pcs of 1*6*12 240 PCs of 15' bamboo 30 lgts of 16mm 100 lgts of 12mm 80 lgts of 10 mm 34 lgts of 8mm Binding wire 25kg 93 bags of cement 3 trips of sharp sand 3trips of 1/2" aggregate Electrical and mechanical fittings excluded All labour cost #235, 000.00 only. Dear Followers discretion is advised.... Let's move on please 1 Share
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by whirlwind7(m): 10:12am On Sep 20, 2017 |
dubemcapital: Will the membrane be removed before screeding the ceiling? I'm thinking if its left in place, the plaster for screeding may not stick to well to the ceiling. Correct? |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 11:04am On Sep 20, 2017 |
[sup][/sup] whirlwind7: Very correct sir, it will be removed before plastering. |
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 9:43pm On Sep 20, 2017 |
Work continues
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 3:14pm On Sep 22, 2017 |
Hmm, the building has no architectural drawing but the client insisted work must continue... So I will have to work out a sketch even more modern designed arrangement at that to prove how good I am in this profession: I think that's what he want.
|
Re: *** Building on an existing structure a storey Of One Bedroom (4 Flats)*** by dubemcapital(m): 7:16pm On Sep 25, 2017 |
Steel work on going...
|
(1) (2) (3) (4) (5) (6) (Reply)
Kitchen Cabinets / Finishing Of 3 units of 3bedrooms Holiday Cottage For Diaspora Client / Architectural Service Only, View Prices And Withing Lagos Only
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 36 |